Difference between revisions of "LB 170048 Nickel Foil Consistency Check"

From New IAC Wiki
Jump to navigation Jump to search
Line 1: Line 1:
Since the Selenium activities are not matching predicted values, check nickel foils from the front and rear to try and get that the activity is the same. Below is a table of pictures and information from ROOT sessions.
+
Since the Selenium activities are not matching predicted values, check nickel foils from the front and rear to try and get that the activity is the same. Below is a table of pictures and information from ROOT sessions. For each of these, the spectrum was weighted by the inverse of the mass. For the front foil the mass was 1.3310g and for the rear foil the mass was
  
  

Revision as of 14:43, 1 November 2017

Since the Selenium activities are not matching predicted values, check nickel foils from the front and rear to try and get that the activity is the same. Below is a table of pictures and information from ROOT sessions. For each of these, the spectrum was weighted by the inverse of the mass. For the front foil the mass was 1.3310g and for the rear foil the mass was


5/23/17 5/26/17 5/29/17 5/29/17 5/30/17
Original Window Counts 880200 716200 617100 545800 394100 362000 346300
Original Window Background (Integrated) 381379 267608 215260 189665 143921 137541 128197
Original Window Difference 498821 448592 401850 356135 250179 224459 218103
Expanded Window Counts 970900 782600 671300 593100 426700 395400 378100
Expanded Window Background 468138 333633 269025 236476 173353 170089 159644
Expanded Window Difference 502762 448967 402275 356624 253347 225311 218456
Error in counts 3941 375 425 489 3168 852 353
.dat file entry 7.416220118 +/- 0.0079006297 7.343988145 +/- 0.0008359489264 7.216858801 +/- 0.0010576086 7.079282677 +/- 0.0013730748 6.908471023 +/- 0.012662933 6.704677244 +/- 0.0037957934 6.622841784 +/- 0.0016185014