While looking to see if certain lines are indeed selenium within the spectrum, it is worth noting that there are 2 states for Se-81. There is a metastable state with a 57 minute half life and a gamma emission of 103 keV. First I will attempt to show that this metastable state can indeed be seen in the spectrum. | While looking to see if certain lines are indeed selenium within the spectrum, it is worth noting that there are 2 states for Se-81. There is a metastable state with a 57 minute half life and a gamma emission of 103 keV. First I will attempt to show that this metastable state can indeed be seen in the spectrum. | ||
+ | |||
+ | ==Pure Selenium Sample== | ||
Below is an overlay of 5 plots with different cuts in time. | Below is an overlay of 5 plots with different cuts in time. | ||
Line 27: | Line 29: | ||
1.14 +\- 0.07 uCi | 1.14 +\- 0.07 uCi | ||
+ | |||
+ | ==10% Se Mixture== | ||
+ | |||
+ | Below is an overlay of the spectra to see the decay over time of the line of interest | ||
+ | |||
+ | [[File:Se81 Meta 10%Se Overlay.png|200px]] | ||
[[PAA_Selenium]] | [[PAA_Selenium]] |
Revision as of 18:01, 21 April 2017
Neutron knockout on Se-82
While looking to see if certain lines are indeed selenium within the spectrum, it is worth noting that there are 2 states for Se-81. There is a metastable state with a 57 minute half life and a gamma emission of 103 keV. First I will attempt to show that this metastable state can indeed be seen in the spectrum.
Pure Selenium Sample
Below is an overlay of 5 plots with different cuts in time.
The half life was calculated using the program /data/IAC/Se/Feb2017Run/LB_WeightedFit.C
Using the slope, the half life can be found to be 58.9 +/- 11 minutes
Below is a plot of the data when it is exponentiated
Since the constant term is inside of the exponent, we must exponentiate the constant to get the (efficiency uncorrected) Activity at t=0.
So the uncorrected activity at t=0 is 379.56 +\- 25.04 Hz. Using the Ba-133 87 keV efficiency at 3.9 cm away from the face of detector B, which is 0.017, the corrected activity can be found to be
22327.06 +\- 1472.94 Hz which converts to 603.43 +\- 39.81 nCi
The sample was measured 55 minutes after the beam was shut off, which brings the activity to
1.14 +\- 0.07 uCi
10% Se Mixture
Below is an overlay of the spectra to see the decay over time of the line of interest