1” Al radiator, collimator slit open, HV -1700V,*Find lowest thresholds to run.
 
1” Al radiator, collimator slit open, HV -1700V,*Find lowest thresholds to run.
 +
{| border="1"
 +
| Run # ||D90 Rate (Counts/pulse)|| Configuration
 +
|-
 +
|5295 || || 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator OPEN , radiator 3/4" IN , '''Target is DU''', UNBlock cell on accelerator side  [[File:Rate2nC_5295.png|40px]]
 +
|-
 +
|}
 +
 
=Study forward detector gamma flas with Pb curtains=
 
=Study forward detector gamma flas with Pb curtains=
 
=Thorium strip, collimator squeeze down.=
 
=Thorium strip, collimator squeeze down.=

Revision as of 17:25, 7 September 2016

No target collimator open

Beam Conditions
11.1 MeV , 2 ns pulse width
Detector HV
=-1700 Volts on all detectors
Run # D90 Rate (Counts/pulse) Configuration
5277 11.1 MeV , 2 ns pulse width , 850 mA , 60 Hz , Collimators wide open , radiator out , Tuning
5286 .18 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Collimators wide open , radiator 3/4" Al , Target is 3/4 thick Al @ 90 degree to beam 5286.png
5288 0.14 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Collimators wide open , radiator Out , Target is 3/4 thick Al @ 90 degree to beam 5288.png
5289 0.02 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator closed , radiator Out , Target is 3/4 thick Al @ 90 degree to beam, Block cell on accelerator side to measure shower from beam dump with max e- hitting dump 5289.png
5290 0.001 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator closed , radiator Out , Target is 3/4 thick Al @ 90 degree to beam, Block cell on accelerator side to measure shower from beam dump with max e- hitting dump, RF OFF a.k.a no beam 5290.png
5291 0.01 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator closed , radiator 3/4" IN , Target is 3/4 thick Al @ 90 degree to beam, Block cell on accelerator side 5291.png
5292 0.01 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator closed , radiator 1.5" IN , Target is 3/4 thick Al @ 90 degree to beam, Block cell on accelerator side 5292.png
5293 0.23 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator OPEN , radiator 3/4" IN , Target is 3/4 thick Al @ 90 degree to beam, UNBlock cell on accelerator side Rate2nC 5293.png
5294 0.08 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator OPEN , radiator 3/4" IN , Target is OUT, UNBlock cell on accelerator side Rate2nC 5294.png
5295 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator OPEN , radiator 3/4" IN , Target is DU, UNBlock cell on accelerator side Rate2nC 5295.png

DU cylinder target

Beam Conditions
11.1 MeV , 2 ns pulse width

1” Al radiator, collimator slit open, HV -1700V,*Find lowest thresholds to run.

Run # D90 Rate (Counts/pulse) Configuration
5295 11.1 MeV , 2 ns pulse width , 850 mA , 200 Hz , Accelerator side collimator open, Cell side collimator OPEN , radiator 3/4" IN , Target is DU, UNBlock cell on accelerator side Rate2nC 5295.png

Study forward detector gamma flas with Pb curtains

Thorium strip, collimator squeeze down.

No target run

Determine how many fissions per pulse.

run 1 mg HEU to see (probably miserable) rates

Exploratory measurements with 47% HEU.

CFD studies

P.S. sweep magnet in/out

Long run on Thorium

Long run on 1 mg HEU