Difference between revisions of "Signal cable timing"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
− | {| border="1" style="border: | + | {| border="1" style="border: 3px solid black; border-collapse: collapse; padding: 5px; text-align: center " |
! colspan="2"|Detector | ! colspan="2"|Detector | ||
!style="border: 1px solid black; border-bottom: 3px solid black; padding: 5px;vertical-align: middle" rowspan="2"| PMT | !style="border: 1px solid black; border-bottom: 3px solid black; padding: 5px;vertical-align: middle" rowspan="2"| PMT |
Revision as of 21:22, 17 August 2016
Detector | PMT | sig. cable | relative to D30T001 [ns] | PMT bot - PMT top [ns] | |
---|---|---|---|---|---|
angle | color | ||||
30 | Red | Top | D30T001 | +0 (by definition) | +15 |
Bot | D30B002 | +15 | |||
90 | Yellow | Top | D90T003 | +1 | +10 |
Bot | D90B004 | +11 | |||
150 | Blue | Top | D150T005 | +1 | +13 |
Bot | D150B006 | +14 | |||
225 | Wood | Top | D225T007 | -3 | +23 |
Bot | D225B008 | +20 |
Trigger plugged into patch panel 223A15 : -8 ns