DC: Integrated Digitized Bank Contents
DC system will measure the momentum of charged particles emerging from the target.
SubBank Number | Variable |
---|---|
1 | Sector |
2 | Superlayer |
3 | Layer |
4 | Wire |
5 | LR |
6 | doca |
7 | sdoca |
8 | time |
9 | stime |
99 | hitn |
Sector
Viewing the Drift Chambers parallel to the beam line, in the x-y plane, the sector numbering runs 1-6 counter-clockwise starting at phi=0 degrees. Each sector is 60 degrees wide in phi, with sector 1 falling within the range -30 to +30 degrees in phi.
Superlayer
Layer
Each Superlayer is composed of 6 layers, numbered sequentially starting from nearest to furthest to the target.