Difference between revisions of "Niowave 11-2015"
Line 29: | Line 29: | ||
|} | |} | ||
− | + | A comparison between the prediction from MCNPX and GEANT4 was once again performed. | |
− | GEANT4 | ||
Revision as of 15:03, 13 April 2016
A 10 MeV electron beam with a radius of 0.5 cm was incident on a 2 mm thick PbBi target. The target is positioned at Z = -902 mm. Niowave Positron Project Progress for November 2015
The next step in the positron project, after determining the PbBi thickness for maximum positron production, was to estimate the heat that would be deposited from the primary electron beam on the beam pipe. Electrons scattered by the PbBi target will intersect a beam pipe used to transport the desired positrons. Electrons traversing the beam pipe can deposit energy that will heat the beam pipe. The goal of this simulation was to estimate the amount of the deposited energy to determine if there is sufficient cooling to prevent a beam pipe breach. Below is a preliminary design of the beam pipe dimensions.
Element | dimension |
Inner beam pipe radius | 1.74 cm |
Inner beam pipe thickness | 0.165 cm |
water jacket thickness | 0.457 cm |
outer beam pipe radius | 2.362 cm |
outer beam pipe thickness | 0.165 cm |
Solenoid inner radius | 2.527 cm |
Solenoid outer radius | 4.406 cm |
A comparison between the prediction from MCNPX and GEANT4 was once again performed.
According to the above figure, GEANT4 predicts a total of
MeV (the integral adds up the energy in each 1cm bin) of energy will be deposited in a 1m long beam pipe surrounding a 2 mm thick PbBi target located at Z=-902 mm when 20 million electrons impinge the target. The peak energy deposition is 0.3 MeV/eIf this energy were uniformly distributed along the 5 mm thick beam pipe having a diameter of 3.48 cm then I would see
if you assume a 1 mA beam of electrons then this becomes
I converted the above histogram to deposited power by 1000 mA, divide by the number of incident electrons, divide by the circumference of the beam pipe, convert the number of electrons to Coulombs, and use a unit conversion from MeV to W-s per MeV.
If you use the above factors to weight the histogram, then the figure below shows that GEANT4 predicts a power deposition density of
, 1 cm downstream of the target. Back scattered electrons appear to create the hottest spot of about 1cm upstream of the target.Power Deposition Zoomed in and 902 mm offset applied | Power deposition over the 1 m long beam pipe |
The energy deposited by electrons scattered into a 3.48 diameter stainless steel beam pipe (1.65 mm thick) from a PbBi target as a function of a uniform Solenoidal magnetic field.
B-field (Tesla) | Hot Spot ( | )
0.0 | 0.35 |
0.3 | 0.35 |
1.0 | 0.35 |
1.5 | 0.22 |
2.0 | 0.10 |
4.0 | 0.002 |
To convert this deposited energy per incident electron on the target to a heat load in the pipe you need to divide by the area of the pipe.
A histogram is filled with 1 cm bins along the Z axis. The surface area becomes
. The beam pipe diameter assumed is 3.48 cm.When filling the histogram binned 1 cm in Z, you should weight it by the amount of depositred energy divided by the circumference of the pipe and divided by the number of incident electrons on the target (5 million). The energy units are converted to keV by multiplying the numberator by 100 or in this case dividing by 5000 instead of 5 million.
TH1F *T00N=new TH1F("T00N","T00N",100,-1000.5,-0.5)
Electrons->Draw("evt.EoutPosZ>>T00N","evt.DepE/10.088/5000")
To convert From Mev/ e- to kW/cm^2 assuming a current of 1mA (10^-3 C/s) you
With SS windows
Positrons->Draw("sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)","evt.BeamPosMomZ>0 && evt.BeamPosPosZ>-500 && sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)<97.4/2");
Positron Collection rates with 60 cm long Solenoid
With SS windows
Positrons->Draw("sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)","evt.BeamPosMomZ>0 && evt.BeamPosPosZ>-500 && sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)<97.4/2");
B-field (Tesla) | 34.8 mm diameter pipe | 47.5 | 60.2 | 72.9 | 97.4 | |
0.0 | 0.35 | 1,2,4,4,5 | 2,3,4,4,6 | 4,4,6,7,9 | 6,8,9,10,11 | 16,14,15,16,17 |
0.1 | 225,236,250,246,249=241 | 10282,282,293,294,306=291 | 10373,366,370,364,373=369 | 4451,437,440,438,451=443 | 7602,584,563,558,570=575 | 18|
0.3 | 0.35 | 626,619,596,619,611 =614 | 11720,726,706,730,717=720 | 9871,864,840,841,834 =850 | 16987,968,939,943,952 =958 | 201118,1106,1069,1067,1080=1088 | 23
0.6 | 929,935,949,969,961=949 | 171022,1031,1046,1059,1052 =1042 | 151120,1130,1152,1154,1146 =1140 | 151168,1184,1210,1221,1206 =1198 | 211212, 1218,1240,1254,1242=1233 | 18|
1.0 | 0.35 | 1117,1085,1083,1061,1085=1086 | 201188,1154,1140,1111,1134=1145 | 281225,1190,1178,1149,1172 =1183 | 281243.1208,1195,1164,1184=1199 | 301252,1219,1206,1178,1200=1211 | 27
1.5 | 0.22 | |||||
2.0 | 0.10 | 1198,1210,1215,1223,1176=1204 | 181216,1227,1235,1241,1196 =1223 | 181237,1243,1252,1257,1214=1241 | 171249,1252,1262,1266,1225 =1251 | 161257,1262,1270,1276,1234=1260 | 16
4.0 | 0.002 |