Determine the Moller background using an [[LH2 target]] to check the physics in GEANT4
Determine the Moller background using an [[LH2 target]] to check the physics in GEANT4
==Momentum distributions in the Lab Frame ==
==Distributions For LH2==
[[LH2 Momentum Lab]]
[[File:FnlMom.png|frame|center|alt=Scattered Electron Momentum in Lab Frame|'''Figure 1a:''' The scattered electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.]]
[[File:MolMom.png|frame|center|alt=Moller Electron Momentum in Lab Frame|'''Figure 1b:''' The Moller electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.]]
==Angular Distribution in the Lab Frame==
==Angular Distribution in the Lab Frame==
Revision as of 22:55, 28 March 2016
need to insert moller shielding into card after moller LUND file is created. (see clas12/beamline)
Simulating the Moller scattering background for EG12
Figure 2a: The scattered electron scattering angle theta distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 2b: The Moller electron scattering angle theta distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Momentum distributions in the Center of Mass Frame
Estimated Momentum Distribution
Noting that the GEANT4 data included data for the Kinetic Energy and not the total energy, we can perform the substitution using
[math]\displaystyle{ E^2=p^2+m^2 }[/math]
Performing the relativistic transformation, we find for an incoming electron with momentum of 11GeV, we should find the momentum in the center of mass to be around 53 MeV .
Figure 3a: The scattered electron momentum distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of Mass frame of reference.
Figure 3b: The Moller electron momentum distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of Mass frame of reference.
Angular Distribution in the Center of Mass Frame
Figure 4a: The scattered electron scattering angle theta distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of Mass frame of reference.
Figure 4b: The Moller electron scattering angle theta distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of Mass frame of reference.
Comparing experimental vs. theoretical for Møller differential cross section 11GeV
We find that the differential cross section scale is [math]\displaystyle{ \frac{d\sigma}{d\Omega}\approx 1.8\times 10^{-3}mb \times 9=16.2\mu b }[/math]
Figure 5a: The theoretical Moller electron differential cross-section for an incident 11 GeV(Lab) electron in the Center of Mass frame of reference.
Converting the number of electrons scattered per angle theta to barns, we can use the relation
where ρtarget is the density of the target material, ltarget is the length of the target, and iscattered is the number of incident particles scattered.
We can use this number to scale the number of electrons per angle to a differential cross-section in barns. Using the plot of the Moller electron scattering angle theta in the Center of Mass frame,
Figure 5b: The Moller electron scattering angle theta distribution for an incident 11 GeV(Lab) electron in the Center of Mass frame of reference.
We can rescale and combine the theoretical differential cross-section for one electron.
TH1F *Combo=new TH1F("TheoryExperiment","Theoretical and Experimental Differential Cross-Section CM Frame",360,90,180);
Combo->Add(MollerThetaCM,1.19e-6);
Combo->Draw();
Theory->Draw("same");
Figure 5c: The experimental and theoretical Moller electron differential cross-section for an incident 11 GeV(Lab) electron in the Center of Mass frame of reference.
Change to a NH3 Target
Replacing the LH2 target with an NH3 target in the ExN02DectectorConstruction.cc file
//Ammonia
G4Element* N = new G4Element("Nitrogen", "N", z=7., a=14.01*g/mole);
G4Element* H = new G4Element("Hydrogen","H",z=1.,a=1.01*g/mole);
G4Material* NH3 = new G4Material("Ammonia", density=0.86*g/cm3, ncomponents=2,kStateGas, temperature, pressure);
NH3->AddElement(N,natoms=1);
NH3->AddElement(H,natoms=3);
Figure 6a: The scattered electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 6b: The Moller electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Increasing the number of incident electrons, Moller Momentum now appears as:
Figure 6c: The Moller electron momentum distribution for 4E8 incident 11 GeV electrons in the Lab frame of reference.
Figure 6d: The scattered electron momentum distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of Mass frame of reference.
Figure 6e: The Moller electron momentum distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of mass frame of reference.
Figure 6f: The Moller electron scattering angle thetea distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 6g: The Moller electron scattering angle theta distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 6h: The Scattered electron scattering angle theta distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of Mass frame of reference.
Figure 6i: The Moller electron scattering angle theta distribution for 4E7 incident 11 GeV(Lab) electrons in the Center of Mass frame of reference.
LH2 Vs. NH3
Plotting the Momentum and Scattering angle Theta in the Lab and Center of Mass frame of reference for LH2 and NH3 targets.
Figure 7a: The scattered electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 7b: The Moller electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 7c: The Scattered electron scattering angle theta distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 7d: The Moller electron scattering angle theta distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure out the offset
Rerunning the GEANT simulation for a target of solo atoms of Carbon 12
Figure 8a: The scattered electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Figure 8b: The Moller electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
These graphs show an offset based upon the density of the target material.
Density of target material
C=2.26 g/cm3
NH3=.86g/cm3
LH2=.07g/cm3
[math]\displaystyle{ \Longrightarrow }[/math]The greater the density, the smaller the solid angle into which the Moller electron will scatter.
Density, atomic mass, and electron number effects
Temporarily changing the density of LH2 to be .86g/cm3, the density of NH3, and altering the atomic mass and electron number, we find
Figure 8c: The Moller electron scattering angle theta distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.
Differential Cross-Section Offset
Comparing this to the theoretical differential cross section:
As shown above , we find that the differential cross section scale is [math]\displaystyle{ \frac{d\sigma}{d\Omega}\approx 16.2\times 10^{-2}mb=16.2\mu b }[/math]
where ρtarget is the density of the target material, ltarget is the length of the target, and iscattered is the number of incident particles scattered.