Difference between revisions of "PbBi PosEventFiles NoGaps 2016"
Line 68: | Line 68: | ||
(x,y,z,E) = -2.93 mm 2.7 mm -10.6 cm 5.09 MeV | (x,y,z,E) = -2.93 mm 2.7 mm -10.6 cm 5.09 MeV | ||
+ | |||
+ | trackPID: -11 trackID: 4 chamberNb: 0 energy deposit: 6.58039e-21 eV position: -0.210618 0.289962 -10.3775 cm momentum: (-0.122366,1.87959,2.84065) time: 3.33262 | ||
===Positrons and Electrons after the SS Exit window=== | ===Positrons and Electrons after the SS Exit window=== |
Revision as of 20:17, 13 February 2016
Event files were generated assuming an ideal solenoid having an inner radius of 2.527 cm surrounding a beam pipe with a radius of 1.74 cm. Electrons impinge a 2mm thick PbBi liquid target that has a surface area of 2.54 cm x 2.54 cm. Stainless steel windows 0.25 mm thick sandwhich the PbBi target at locations Z= and Z= cm. The target is located at Z = cm and the beam begins 20 cm upstream at Z = cm. The incident electron beam is a 0.5 cm radius cylinder.
Positrons exiting the Solenoid
The solenoid design has changed such that the max field is 0.20 Tesla (0.22) and its length is 150 mm.
In other words I should generate position and momentum files for positrons and electrons at the Z location 15 cm downstream from the middle of the LBE target and within a 3.48 cm diameter beam pipe.
/vis/viewer/zoom 2
/gps/pos/centre 0.0 0.0 -150.
/vis/viewer/panTo -90.1 0 cm
/vis/viewer/reset
Twenty (20) million incident electrons with an energy of 10 MeV and forming a cylindrical beam with a 0.5 cm radius cylinder impinged a 2mm thick LBE target located at Z = -106 mm. The Z location of positrons exiting the beam pipe at the end of the 15 cm long solenoid is 44 mm. The positrons are 150.00 mm from the middle of the LBE target (Z=44mm).
A space delimited text file with the above events in the format of
PID, x(mm),y,z,Px,Py,Pz(MeV),t(ns)
in units of cm for distance and MeV for momentum is located at
for positrons
http://www2.cose.isu.edu/~foretony/Positrons_2mm10MeVCyl.dat
and
http://www2.cose.isu.edu/~foretony/Electrons_2mm10MeVCyl.dat
The file below contains all the positrons that were created at the target
format
A space delimited text file with the above events in the format of
Initial electron (x,y,z,Px,Py,Pz), Final electron (t,x,y,z,Px,Py,Pz), Positron location after leaving LBE target (t,x,y,z,Px,Py,Pz),Location of positron as it exits a SS window (t,x,y,z,Px,Py,Pz). Units are ns, mm, MeV/c.
http://www2.cose.isu.edu/~foretony/AllPositrons_2mm10MeVCyl.dat
Sample Events
(x,y,z,E) = -2.93 mm 2.7 mm -10.6 cm 5.09 MeV
trackPID: -11 trackID: 4 chamberNb: 0 energy deposit: 6.58039e-21 eV position: -0.210618 0.289962 -10.3775 cm momentum: (-0.122366,1.87959,2.84065) time: 3.33262
Positrons and Electrons after the SS Exit window
The same configuration as the previous subsection except that the 1mm thick sensitive detector is placed at Z = -100.5 mm. Most of the electrons exit at Z = -100.9 mm.
A space delimited text file with the above events in the format of
PID, x(mm),y,z,Px,Py,Pz(MeV),t(ns)
in units of cm for distance and MeV for momentum is located at
for positrons
23500 Positrons in the file below
http://www2.cose.isu.edu/~foretony/PositronsAtExitWindow.dat
and
297216 electrons in the file below
http://www2.cose.isu.edu/~foretony/ElectronsAtExitWindow.dat