Difference between revisions of "PbBi THickness PntSource"

From New IAC Wiki
Jump to navigation Jump to search
 
Line 1: Line 1:
 +
 +
2mm thick PbBi, 10 MeV,  point source
 +
G4beamline pencil beam 10 cm radius
 +
<pre>
 +
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \
 +
        sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \
 +
      meanMomentum=10. sigmaE=0. maxR=10.
 +
</pre>
 +
 +
{| border="1"
 +
| PbBi Thickness (mm) || #positrons/million electrons (G4Beamline)|| #positrons/million electrons (MCNPX)
 +
|-
 +
| 1    ||  || 1091
 +
|-
 +
| 1.5    ||  || 1728
 +
|-
 +
| 2    || 1902<math>\pm</math> 43 || 1984
 +
|-
 +
| 2.5    ||  || 2062
 +
|-
 +
| 3|| <math>\pm</math> 13|| 1986
 +
|-
 +
| 3.5||  || 1938
 +
|-
 +
| 4||<math>\pm</math> 39 || 1858
 +
|-
 +
| 5||  || 1646
 +
|-
 +
| 6|| <math> \pm</math> 37 || 1541
 +
|-
 +
| 10||  || 1216
 +
|-
 +
|}
 +
  
  
 
[[G4Beamline_PbBi#PbBi_THickness_PntSource]]
 
[[G4Beamline_PbBi#PbBi_THickness_PntSource]]

Revision as of 22:49, 14 May 2015

2mm thick PbBi, 10 MeV, point source G4beamline pencil beam 10 cm radius

beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \
        sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \
      meanMomentum=10. sigmaE=0. maxR=10.
PbBi Thickness (mm) #positrons/million electrons (G4Beamline) #positrons/million electrons (MCNPX)
1 1091
1.5 1728
2 1902[math]\pm[/math] 43 1984
2.5 2062
3 [math]\pm[/math] 13 1986
3.5 1938
4 [math]\pm[/math] 39 1858
5 1646
6 [math] \pm[/math] 37 1541
10 1216


G4Beamline_PbBi#PbBi_THickness_PntSource