Difference between revisions of "G4Beamline PbBi"
Jump to navigation
Jump to search
Line 32: | Line 32: | ||
| 2.5 || 1997 || | | 2.5 || 1997 || | ||
|- | |- | ||
− | | 3|| 2233 || | + | | 3|| 2233 || 1986 |
|- | |- | ||
| 3.5|| 2193 || | | 3.5|| 2193 || |
Revision as of 20:16, 28 April 2015
Development of a Positron source using a PbBi converter and a Solenoid
Converter target properties
Definition of Lead Bismuth
1cm diameter target
2 mm thick PbBi
0.5 Tesla solenoid
G4BeamLine and MCNPX
Target thickness optimization
First simple test is to send 1 million, 10 MeV electrons towards a PbBi target and count how many positrons leave the downstream side
The Random number seed is set by Time in G4beamline to use a different set of pseudo random numbers each time it is run
PbBi Thickness (mm) | #positrons/million electrons (G4Beamline) | #positrons/million electrons (MCNPX) |
1 | 960 | 1091 |
1.5 | 1508 | |
2 | 1963 | 1984 |
2.5 | 1997 | |
3 | 2233 | 1986 |
3.5 | 2193 | |
4 | 2184 | 1858 |
5 | 2042 | |
6 | 1851 | 1541 |
10 | 1480 |