=Progress Reports=
 
 
 
==December 08, 2013==
 
*The updated drawing of bricks with remeasured front plate's holes created (drawing #2013.1.001.0001)
 
 
==December 09, 2013==
 
*The list of possible manufacturing company for Brick's Housing (BH) parts production is established:
 
**Partner Steel Co, Inc, Pocatello;
 
**Valley Sheet Metal (VSM) Technologies, Idaho Falls;
 
**Primear Technology, Blackfoot;
 
**Northwest wire EDM, Spokane, WA;
 
**Nelson Metal Technology, Payette, ID;
 
**Water Jet Cutting, Albuquerque;
 
*All above companies have been contacted for quotes. Criteria were price and speed of production.
 
 
==December 10, 2013==
 
*Brick's Housing (BH) parts (steel/AL/PMMA sheets) drawings is approved by Spielman (drawings #2013.1.001.0002-0009)
 
 
==December 11, 2013==
 
*VSM Technologies: selected as manufactured company for BH parts (drawings #2013.1.001.0002-0009)
 
 
==December 17, 2013==
 
*BH parts arrived at IAC and inspected. Kevin is going to assemble and weld them all together.
 
 
==December 18, 2013==
 
*Cathode/anode drawings submitted to Spielman for approving (drawings #2013.1.001.0010-0017)
 
*PMMA_Output_Sheet/Charging_Isolating_Tube drawings submitted to Spielman for approving (drawings #2013.1.001.0018-0019)
 
*X-pinch driver assembly drawing with included cathode/anode submitted to Spielman for approving (drawing #2013.1.001.0020)
 
*PARKER's Viton O-rings V0769-60 2-246 (2 pcs), ID 4 1/2 and W 1/8", selected for vacuum seal inside the cathode/anode section.
 
 
==December 19, 2013==
 
*LESKER reduced 4-way cross (C-0800-275, $890) found as a candidate for vacuum chamber [http://www.lesker.com/newweb/flanges/fittings_cf_crosses.cfm?pgid=4wayreducer];
 
*LESKER reduced 4-way cross drawing downloaded and incorporated into SolidWorks (assembly file Lesker_C-800_275\C-0800-275_reassembled);
 
*LESKER reduced 4-way cross redesigned to match our x-pinch driver (drawing file Lesker_C-800_275\2013.1.001.0030);
 
 
==December 20, 2013==
 
*Some changes to parts have been done to accommodate LESKER redesigned cross:
 
**1) for Al output plate, the inner cut increased from 4.5 diameter to 10" diameter to match the cross (drawing #2013.1.001.0008);
 
**2) for anode can, the slot size increased from 0.4" to 0.5" to march x-pinch wires length  (drawing #2013.1.001.0014);
 
*Reassembled LESCER cross drawing submitted to Spielman for approving (drawing LESKER C-0800-275_REASSEMBLED)
 
*X-pinch driver assembly drawing with included cathode/anode/cross submitted to Spielman for approving (drawing #2013.1.001.0021)
 
*LESCER cross and new assembly drawings is approved by Spielman:
 
 
==December 30, 2013==
 
* LESKER reduced 4-way cross (C-0800-275, $890) is ordered [http://www.lesker.com/newweb/flanges/fittings_cf_crosses.cfm?pgid=4wayreducer]. Expected delivery id January 16, 2014. Comments: this one we will cut and reassemble later in the way we need. Just to remind, I plan two use one 8" flange for plate connection, one 8" flange for x-pinch access and vacuum pump connection, one 2 3/4 flange for x-ray diagnostics and one 2 3/4 flange for x-ray output.
 
 
* for x-ray windows we  can use Beryllium window (available from Moxtek in 1-1/3 and 2-1/8 CF flanges [http://www.eurotek-general.com/upload/PDF/Moxtek/DuraBeryllium%20Windows%20in%20ConFlat%20Flanges,%20WIN-TECH-1001.pdf]).
 
[[File:Be transmission data1.jpg | 400 px]]
 
 
For 2-1/8 CF flanges x-ray window, we will need Zero-Length Reducer Flange (from 2 3/4 to 2 1/8), like [http://www.lesker.com/newweb/flanges/flanges_cf_reducer.cfm?pgid=std]
 
 
* '''can we use quartz window instead of beryllium?''' (we can probably borrow one from IAC stock);
 
* do we need RIGHT NOW x-ray window? A: no, we will need just glass viewport for x-pinch visual observation;
 
 
==December 31, 2013==
 
Other parts we need for vacuum chamber are:
 
*flanges:
 
** 8" fixed blank CF flange, Lesker part #F0800X000N, $125 [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=8in]. Note: I would cut this flange in the middle to reduce the weight twice from 12 -> 6 lbs;
 
** 2 3/4" fixed bore 1.63" CF flange, Lesker part #F0275X175N, $15 [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=2d75in]. Note: this flange will be used for x-ray diode's mounting;
 
** 2-3/4" CF flange viewport window. Note: this flange will be used for visual x-pinch observation. Later this flange can be replaced by x-ray window. Choose the cheapest (first) one:
 
*** Corning 7056 Glass Viewport - 2.75" CF Flange, Accu-Glass Products, $125 [https://accuglassproducts.com/product.php?productid=17478&cat=569&page=1];
 
*** Conflat Flange (CF) Zero Length Glass Viewport 1.5 inch to CF 2-3/4 inch, Ideal Vacuum Products, 179.95 [http://www.pchemlabs.com/product.asp?pid=2262];
 
*** 2 3/4" CF flange Sapphire Viewports, Lesker part #VPZL-275SW, $650 [http://www.lesker.com/newweb/flanges/viewports_cf_sapphire.cfm?pgid=0];
 
*gaskets [http://www.lesker.com/newweb/flanges/hardware_cf_gaskets.cfm?pgid=ofhc]:
 
** 1/4 Hard OFHC Copper Gasket for 2-3/4" CF flange, Lesker part #GA-0275, set of 10, $26.40;
 
** 1/4 Hard OFHC Copper Gasket for 8" CF flange, Lesker part #GA-0800, set of 10, $75.00.
 
*fasteners [http://www.lesker.com/newweb/flanges/flanges_cf_304SS.cfm?pgid=2d75in scroll down]:
 
** 5/16—24 x 2-1/4" Bolt & Nut Set, Lesker part #HBS31224225, set of 25, $37.58 (for 8" flange up);
 
** 5/16—24 x 1-3/4" Bolt Kits, Lesker part #HBK31224175, set of 25, $30.60 (for 8" flange Al plate connection), '''(need 1" length)''';
 
** 1/4—28 x 1-3/8" Bolt & Nut Set, Lesker part #HBS25028138, set of 25, $29.38 (for 2-3/4" flanges);
 
 
*Total quote is '''xxx.xx''' plus shipping.
 
 
==January 02, 2014==
 
*Al output plate drawing #2013.1.001.0008 is updated to accommodate vacuum chamber's cross (11" cut changed to 8" and added slot cuts for small flanges);
 
*Reassembled Lesker cross drawing #2013.1.001.0030 is updated (file name changed and added some dimensions for clarity);
 
*Assembly drawing #2013.1.001.0021 is updated for clarity;
 
 
==January 02, 2014==
 
PMMA groove's o-ring design
 
 
*o-ring material :
 
** Viton (V1436-75, V1475-75, V1476-75);
 
** assumption made:
 
*** viton = fluorocarbon;
 
*** hardness we nee 70-80;
 
 
*o-ring size nominal: ID=4-1/2, OD=4-3/4, W=1/8;  o-ring size actual: ID=4.484", W=0.139"; Parker size number 2-246;
 
 
*we need o-ring:
 
** V1436-75 2-246;
 
** V1475-75 2-246;
 
** V1476-75 2-246;
 
 
*grove shape and dimensions:
 
** chapter 4.3, section IV - static o-ring sealing, Parker o-ring handbook.pdf:
 
*** groove shape standard;
 
*** ID=4.484", W=0.161", OD=4.806", Depth = 0.104", R=0.017", Finish = 16 RMS uinch;
 
** also see Eriks groove/o-ring calculator [http://oringcalculator.eriksgroup.com/#], pdf report [[File:03012014162515.pdf]];
 
** assumption made:
 
*** external pressure;
 
*** ID(groove) = ID (actual o-ring size);
 
*** o-ring deformation is about 25%;
 
 
* o-ring's grooves included into the PMMA drawing #2013.1.001.0018;
 
 
=X-pinch driver fabrication to do list=
 
*Can we use cross instead of cube? '''(A: Cross - not, but reduced cross - yes)''';
 
*Do we need to use Cu gasket to seal CF flange? If so, we need a lot of them for every shot. '''(A: yes, we need to use Cu gaskets)''';
 
 
 
*X-pinch cathode/anode design and fabrication:
 
**Design x-pinch cathode/anode '''(in progress, drawings #2013.1.001.0010-0021 is finished and need to be approved by Spielman)''';
 
**Discuss possibilities of fabrication in IAC with Kevin;
 
**Fabricate anode/cathode/vacuum_chamber parts, drawings #2013.1.001.0010-0021;
 
 
 
*X-pinch vacuum chamber design and fabrication:
 
**Design x-pinch vacuum chamber, '''(done: drawings #2013.1.001.0021 (assembly)  and 2013.1.001.0030 (Lesker reassembled cross))''';
 
**Include Al plate's taped holes in drawing #2013.1.001.0008 '''(done)''';
 
**Discuss reassembling possibilities with Kevin;
 
**Buy all parts for x-pinch vacuum chamber:
 
***Buy LESKER 8"/2-3/4" reducing cross '''(done: bought on 12/30/13, RACL60, expected delivery Jan 16, 2014)''';
 
***Identify all flanges/viewports/gaskets/fasterners for cross;
 
***Buy all flanges/viewports/gaskets/fasterners for cross;
 
 
 
*O-Rings:
 
**Identify o-rings ('''done''');
 
**design o-ring groove '''(done)''';
 
**Include o-ring's grooves into the PMMA drawing #2013.1.001.0018 ('''done''');
 
**Identify/buy o-rings;
 
 
 
*Identify/buy charging lines;
 
*Locate vacuum pump
 
 
 
*Diagnostics: Rogowskii and B-Dot:
 
**Read Rick's notes and paper;
 
**design and include in drawing;
 
**fabricate;
 