Difference between revisions of "TF CPAA Log"

From New IAC Wiki
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 11: Line 11:
 
|5352 || looking for HpGE spectrum using 1 micro-Curie Na-22 source  
 
|5352 || looking for HpGE spectrum using 1 micro-Curie Na-22 source  
 
|-
 
|-
 +
|}
 +
 +
===6/21/13===
 +
 +
signal to discriminator is not attenuated
 +
 +
{|border="1"  | cellpadding="20" cellspacing="0  class="wikitable"
 +
|-
 +
|run number || Source|| Detector || Disc (V) || Atten (dB) || Comments
 +
|-
 +
|5362 || 9 uCi Na-22  ||  B || 0.64 || 6 ||
 +
|-
 +
|5363 || 10 uCi Co-60 ||  B || 0.64 || 6||
 +
|-
 +
|5372|| 10 uCi Co-60 ||  180-3 ||1.96  || 9||
 +
|-
 +
|5373 || 9 uCi Na-22 ||  180-3 || 1.96  || 9||
 +
|-
 +
|5374 || 9 uCi Na-22 ||  180-3 || 1.96 || 8||
 +
|-
 +
|5375 || 10 uCi Co-60 ||  180-3|| 1.96 || 8||
 +
|-
 +
|5377 || 10 uCi Co-60 ||  180-3 || 0.42 || 8||
 +
|-
 +
|5378 || 9 uCi Na-22 || 180-3 || 0.42 || 8||
 +
|-
 +
|5379 || 9 uCi Na-22 ||  180-3 || 0.64 || 8||
 +
|-
 +
|5380 || 9 uCi Na-22 ||  180-3 || 0.80 || 9||
 +
|-
 +
|5381 || 9 uCi Na-22 ||  180-3 || 0.80 || 9||
 +
|-
 +
|5382 || 10 uCi Co-60 ||  B || 0.64 || 6||
 +
|-
 +
|5383 || 9 uCi Na-22 ||  B || 0.64 || 6||
 +
|-
 +
|5384 || 9 uCi Na-22 ||  B || 0.64 || 6|| sent detector B output to timing amp used by detector 180-3
 +
|-
 +
|5385 || 9 uCi Na-22 ||  B || 0.64 || 4||
 +
|-
 +
|5386 || 9 uCi Na-22 ||  B || 0.64 || 0||
 +
|-
 +
|5387 || 9 uCi Na-22 ||  B || 0.64 || 0|| increased timing amp to x2 instead of x1
 +
|-
 +
|5388 || 9 uCi Na-22 ||  B || 0.64 || 4||
 +
|-
 +
|5389 || 9 uCi Na-22 ||  B || 0.64 || 8||
 +
|-
 +
|5390 || 10 uCi Co-60  ||  B || 0.64 || 8||
 +
 +
 +
 +
 
|}
 
|}
  

Latest revision as of 14:52, 26 June 2013

DAQ setup

ADC readout

Running configuration 1495SA (v1495 TS with Scaler and Adc)

run number conditions
5352 looking for HpGE spectrum using 1 micro-Curie Na-22 source

6/21/13

signal to discriminator is not attenuated

run number Source Detector Disc (V) Atten (dB) Comments
5362 9 uCi Na-22 B 0.64 6
5363 10 uCi Co-60 B 0.64 6
5372 10 uCi Co-60 180-3 1.96 9
5373 9 uCi Na-22 180-3 1.96 9
5374 9 uCi Na-22 180-3 1.96 8
5375 10 uCi Co-60 180-3 1.96 8
5377 10 uCi Co-60 180-3 0.42 8
5378 9 uCi Na-22 180-3 0.42 8
5379 9 uCi Na-22 180-3 0.64 8
5380 9 uCi Na-22 180-3 0.80 9
5381 9 uCi Na-22 180-3 0.80 9
5382 10 uCi Co-60 B 0.64 6
5383 9 uCi Na-22 B 0.64 6
5384 9 uCi Na-22 B 0.64 6 sent detector B output to timing amp used by detector 180-3
5385 9 uCi Na-22 B 0.64 4
5386 9 uCi Na-22 B 0.64 0
5387 9 uCi Na-22 B 0.64 0 increased timing amp to x2 instead of x1
5388 9 uCi Na-22 B 0.64 4
5389 9 uCi Na-22 B 0.64 8
5390 10 uCi Co-60 B 0.64 8



6/25/13

run number conditions
5396 1 uCi Na-22 source using Detector B, atten = 9db
5397 1 uCi Na-22 source using Detector B, atten = 6db, rate is about 140 Hz, discriminator = 0.63 V
5398 1 uCi Co-60 source using Detector B, atten = 6db, rate is about 200 Hz, discriminator = 0.63 V
5399 10 uCi Co-60 source using Detector B, atten = 6db, rate is about 1460 Hz, discriminator = 0.63 V, R5399 ADC4.png
5400 9 uCi Na-22 source using Detector B, atten = 6db, rate is about 850 Hz, discriminator = 0.63 V,R5400 ADC4.png


PAA_CoincidenceCounting PAA_Research