Difference between revisions of "2n preliminary data analysis"
(Created page with 'Data on <math>H_2O/D_2O</math>:') |
|||
(66 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | Data on <math> | + | Data on <math>MT target/D_2O</math>: |
+ | |||
+ | Run with 2 Al sheets (2x0.678 mm) as bremsstrahlung converter w/o hardener. | ||
+ | <math>E_e = 10.5 MeV</math>, Detector G(1/left). | ||
+ | |||
+ | [[File:D2OMTT.jpg | 600 px]] | ||
+ | |||
+ | Bin-by-bin subtraction of the two timing spectra after normalization: | ||
+ | |||
+ | [[File:Subtr_D2OMTT.jpg | 600 px]] | ||
+ | |||
+ | '''Data on thick U-target and D2O from 8/13/2012:''' | ||
+ | |||
+ | Data (detector G(1,2)) were normalized to the gun trigger signal. Runs 3999(D2O) and 4001(no target), and 4011(thick U-target) and 4012(no target). | ||
+ | |||
+ | [[File:D2OMTT2.png | 600 px]] | ||
+ | |||
+ | [[File:ThickUtarg.png | 600 px]] | ||
+ | |||
+ | |||
+ | '''Data on thick U-target,D2O and H2O from 8/16/2012:''' | ||
+ | |||
+ | Data (detector F(1)) were normalized to the gun trigger signal. Runs 4097(D2O) and 4098(H2O), and 4011(thick U-target) and 4012(no target). <math>E_e = 10.5 MeV</math> | ||
+ | |||
+ | [[File:D2OH2O.png | 600 px]] | ||
+ | |||
+ | [[File:D2OMTT3.png | 600 px]] | ||
+ | |||
+ | Data (detector H(2)) were normalized to the gun trigger signal. Runs 4100(thick U-taget) and 4099(MT target). <math>E_e = 10.5 MeV</math> | ||
+ | |||
+ | [[File:ThickUtargMTtarget.png | 600 px]] | ||
+ | |||
+ | Photon flux study. | ||
+ | |||
+ | The current we were running at (3 sheets of Al): | ||
+ | |||
+ | [[File:photon_fluxI.png | 600 px]] | ||
+ | |||
+ | And when we asked the operator to cut the electron current twice, our photon flux monitor showed: | ||
+ | |||
+ | [[File:photon_fluxI_half.png | 600 px]] | ||
+ | |||
+ | |||
+ | '''Data on thick U-target,D2O and H2O from 8/17/2012:''' | ||
+ | |||
+ | Detector layout: | ||
+ | |||
+ | [[File:Detector_layout2.png]] | ||
+ | |||
+ | Geant4 setup: | ||
+ | |||
+ | [[File:geant_setup.eps | 600 px]] | ||
+ | |||
+ | Solid angles subtended by the detectors and defined by point source (second column) and volume source filled with deuterium and 1 MeV neutrons were generated through all the volume isotropically (third column): | ||
+ | {|class="wikitable1" | ||
+ | |Det E || | ||
+ | |0.106 || | ||
+ | |0106 | ||
+ | |sr | ||
+ | |- | ||
+ | |Det M || | ||
+ | |0.118 || | ||
+ | |0.119 | ||
+ | |sr | ||
+ | |- | ||
+ | |Det F || | ||
+ | |0.096 || | ||
+ | |0.094 | ||
+ | |sr | ||
+ | |- | ||
+ | |Det G || | ||
+ | |0.063 || | ||
+ | |0.061 | ||
+ | |sr | ||
+ | |- | ||
+ | |Det H || | ||
+ | |0.033 || | ||
+ | |0.031 | ||
+ | |sr | ||
+ | |- | ||
+ | |Det K || | ||
+ | |0.019 || | ||
+ | |0.018 | ||
+ | |sr | ||
+ | |- | ||
+ | |Det I || | ||
+ | |0.011 || | ||
+ | |0.011 | ||
+ | |sr | ||
+ | |} | ||
+ | |||
+ | |||
+ | Calibration of detector array efficiency via D2O photodisintegration (run 4111): | ||
+ | |||
+ | [[File:D20_eff_calibr1.png | 600 px]] | ||
+ | |||
+ | And the rest of the detectors: | ||
+ | |||
+ | [[File:D20_eff_calibr2.png | 600 px]] | ||
+ | |||
+ | Jitter of the PS detector and "Ilyusha" (placed on the beam) w.r.t. the gun trigger signal (run 4112): | ||
+ | |||
+ | [[File:Jitter.png | 600 px]] | ||
+ | |||
+ | H2O calibration run (run 4112): | ||
+ | |||
+ | [[File:H20_eff_calibr1.png | 600 px]] | ||
+ | |||
+ | And the rest of the detectors: | ||
+ | |||
+ | [[File:H20_eff_calibr2.png | 600 px]] | ||
+ | |||
+ | Run with MT target (run 4113): | ||
+ | |||
+ | [[File:MT_calibr1.png | 600 px]] | ||
+ | |||
+ | And the rest of the detectors: | ||
+ | |||
+ | [[File:MT_calibr2.png | 600 px]] | ||
+ | |||
+ | Thick U-target data (run 4118): | ||
+ | |||
+ | [[File:r4118_1.png | 600 px]] | ||
+ | |||
+ | And the rest of the detectors: | ||
+ | |||
+ | [[File:r4118_2.png | 600 px]] | ||
+ | |||
+ | Neutron data bank (two production runs 4118 and 4119 added together). Coincidences between two PMTs for each detector are shown below. | ||
+ | |||
+ | [[File:neutron_bank.png | 600 px]] | ||
+ | |||
+ | |||
+ | '''Some simulation''' | ||
+ | |||
+ | Neutron energy and neutron polar angular distribution from D2O photodisintegration by unpolarized bremmstrahlung photons with end point energy 10.5 MeV were simulated by G4. | ||
+ | |||
+ | Bremsstrahlung photon spectrum: | ||
+ | |||
+ | [[File:brem_spectrum.png | 600 px]] | ||
+ | |||
+ | Neutron energy spectrum w/o target material effect: | ||
+ | |||
+ | [[File:Neutron_simulation.png | 600 px]] | ||
+ | |||
+ | Neutron polar angular distribution. Zero degree is the initial incident photon direction: | ||
+ | |||
+ | [[File:Neutron_polar_ang_simulation.png | 600 px]] |
Latest revision as of 04:20, 20 August 2012
Data on
:Run with 2 Al sheets (2x0.678 mm) as bremsstrahlung converter w/o hardener.
, Detector G(1/left).Bin-by-bin subtraction of the two timing spectra after normalization:
Data on thick U-target and D2O from 8/13/2012:
Data (detector G(1,2)) were normalized to the gun trigger signal. Runs 3999(D2O) and 4001(no target), and 4011(thick U-target) and 4012(no target).
Data on thick U-target,D2O and H2O from 8/16/2012:
Data (detector F(1)) were normalized to the gun trigger signal. Runs 4097(D2O) and 4098(H2O), and 4011(thick U-target) and 4012(no target).
Data (detector H(2)) were normalized to the gun trigger signal. Runs 4100(thick U-taget) and 4099(MT target).
Photon flux study.
The current we were running at (3 sheets of Al):
And when we asked the operator to cut the electron current twice, our photon flux monitor showed:
Data on thick U-target,D2O and H2O from 8/17/2012:
Detector layout:
Geant4 setup:
Solid angles subtended by the detectors and defined by point source (second column) and volume source filled with deuterium and 1 MeV neutrons were generated through all the volume isotropically (third column):
Det E | 0.106 | 0106 | sr | ||
Det M | 0.118 | 0.119 | sr | ||
Det F | 0.096 | 0.094 | sr | ||
Det G | 0.063 | 0.061 | sr | ||
Det H | 0.033 | 0.031 | sr | ||
Det K | 0.019 | 0.018 | sr | ||
Det I | 0.011 | 0.011 | sr |
Calibration of detector array efficiency via D2O photodisintegration (run 4111):
And the rest of the detectors:
Jitter of the PS detector and "Ilyusha" (placed on the beam) w.r.t. the gun trigger signal (run 4112):
H2O calibration run (run 4112):
And the rest of the detectors:
Run with MT target (run 4113):
And the rest of the detectors:
Thick U-target data (run 4118):
And the rest of the detectors:
Neutron data bank (two production runs 4118 and 4119 added together). Coincidences between two PMTs for each detector are shown below.
Some simulation
Neutron energy and neutron polar angular distribution from D2O photodisintegration by unpolarized bremmstrahlung photons with end point energy 10.5 MeV were simulated by G4.
Bremsstrahlung photon spectrum:
Neutron energy spectrum w/o target material effect:
Neutron polar angular distribution. Zero degree is the initial incident photon direction: