=Target= | =Target= | ||
==Introduction== | ==Introduction== | ||
− | Polarized targets and polarized beams are | + | Polarized targets and polarized beams are recently acquired research tools being used to investigate the spin structure of the nucleon. Inclusive scattering experiments using polarized targets and beams facilitate measurements of observables exhibiting spin degrees of freedom, like the spin structure of the nucleon, the electromagnetic structure of the nucleon in its ground state, etc. <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". ''Nucl. Instr. Meth'' '''A 427/3''', 440-454</ref> The technology producing targets containing polarized nucleons have been developed over the past 50 years. For the experiments using electrons as probes, due to the small cross section of the electromagnetic interactions, one of the requirements for polarized targets are a large thickness and resistance to the electron beam intensity without significant radiation damage. The solid targets for the EG1B experiment were polarized via the Dynamic Nuclear Polarization (DNP) method<ref name="CrabbMeyer1997"> Crabb, D.G., Meyer, W.(1997). "Solid Polarized Targets for Nuclear and Particle Physics Experiments". ''Annu. Rev. Nucl. Part. Sci'' '''47''', 67-109</ref>.<br> |
− | + | EG1b polarized target system consists the following main components: the superconducting Helmholtz coils to reach 5 T magnetic field, the evaporation refrigerator for target cooling, the microwaves to induce spin flip in the target, NMR system measuring the target polarization and the housing for the solid target <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". ''Nucl. Instr. Meth'' '''A 427/3''', 440-454</ref>. <br> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
{| border="0" style="background:transparent;" align="center" | {| border="0" style="background:transparent;" align="center" | ||
|- | |- | ||
Line 40: | Line 13: | ||
===Target Magnet=== | ===Target Magnet=== | ||
− | A 5 T magnetic field is established using a pair of superconducting Helmholtz coils made out of Niobium-Titanium mixture with a critical temperature of 9 K. The magnet becomes superconducting below its critical temperature. | + | A 5 T magnetic field is established using a pair of superconducting Helmholtz coils made out of Niobium-Titanium mixture with a critical temperature of 9 K. The magnet becomes superconducting below its critical temperature. In order to establish a current in the coils, a section of the magnetic is warmed above its critical temperature. This process is called "magnet energization". After the coils have been energized, the "magnet switch" section of the coils is cooled down and the current in the leads is ramped down. The full current of the magnet is carried by the superconducting Helmholtz coils. <br> |
{| border="0" style="background:transparent;" align="center" | {| border="0" style="background:transparent;" align="center" | ||
|- | |- | ||
Line 46: | Line 19: | ||
[[File:TheTargetMagnet.png|400px|thumb|The Schematic of the Target Magnet.]] | [[File:TheTargetMagnet.png|400px|thumb|The Schematic of the Target Magnet.]] | ||
|}<br> | |}<br> | ||
− | The superconducting coils are oriented such that the magnetic field is parallel to the incident beam direction. The field induces the hyperfine splittings needed to polarize the target material using 140 Ghz RF | + | The superconducting coils are oriented such that the magnetic field is parallel to the incident beam direction. The field induces the hyperfine splittings needed to polarize the target material using 140 Ghz RF wave. The uniformity of the field varies less than <math>10^{-4}</math> over a cylindrical volume of 20 mm in diameter and length. This configuration is necessary for DNP. The particles with scattering angles between 0-50 degrees are detected in the CLAS as well as 75-105 degrees. The Helmholtz coils block particles scattering between 50 and 75 degrees. The target magnetic field does not interact with the electron beam, however, it is effective in shielding the drift chambers from low energy Moller electrons. The target field bends scattered particles in the azimuthal direction and falls rapidly with distance as (<math>~ 1/r^3</math>). The effect of the magnetic field on the drift chambers is negligible <ref name="Chen2006">Chen, S. (2006). ''First Measurement of Deeply Virtual Compton Scattering with a Polarized Proton Target''. Doctoral dissertation. Florida State University, Tallahasee, FL. </ref> . |
===The Evaporation Refrigerator=== | ===The Evaporation Refrigerator=== | ||
− | The target material is located at the center of the magnet in a separate chamber, | + | The target material is located at the center of the magnet in a separate chamber, called the banjo. Cooling the target to approximately 1 K was achieved using a <math>^{4}He</math> evaporation refrigerator inserted through a 20 cm diameter pumping tube. The pumping tube connects the banjo and the pumping system. The components of the refrigerator are the sintered copper separator pot, two series of heat exchangers, and two lines that supply helium to the banjo. The phase separator allows the liquid to pass, but blocks the helium vapor. The helium vapor is pumped away to cool the radiation baffles. The liquid in the phase separator is directed to the banjo one of the two lines. The heat exchangers remotely controlled by needle valves. The presence of the liquid helium in the target chamber cools target material effectively <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". ''Nucl. Instr. Meth'' '''A 427/3''', 440-454</ref> . |
===The Microwave System=== | ===The Microwave System=== | ||
− | + | The 140 GHz microwave used for DNP are supplied by the Extended Interaction Oscillator (EIO) tube providing <math>16 W</math> power at the anode with a ~ <math>2 GHz</math> bandwidth tube. The frequency can be adjusted by mechanically changing the size of the resonant cavity. Using the high power voltage supply (<math>10 kV</math>) the microwave frequency can be finely tuned over a range of <math>200 MHz</math> <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". ''Nucl. Instr. Meth'' '''A 427/3''', 440-454</ref> . The negative and positive spin states of the nucleon differ by ~ <math>400 MHz</math>, because of that the target polarization orientation can be changed by varying the microwave frequency. Flipping the target spin using microwaves instead of changing the Helmholtx field direction allow one to investigate target polarization systematic effect. <br> | |
− | + | Microwaves are delivered to the target material using a <math>WR-6</math> rectangular gold-plated wave guide located outside the cryostat and a <math>5 mm</math> tube made out of <math>CuNi</math> inside the wave guide system. The <math>CuNi</math> tube and the wave guide are connected by a rectangular-circular adapter. This allows microwaves to travel through the tube and into the rectangular segment of the wave guides suppling microwaves to the desired target cell during the experiment <ref name="Prok2004"> Prok, Y. A. (2004). ''Measurement of The Spin Structure Function <math>g_{1}(x,Q^{2})</math> of The Proton in The Resonance Region''. Doctoral dissertation. University of Virginia, Richmond, VA.</ref>. <br> | |
===The Nuclear Magnetic Resonance System=== | ===The Nuclear Magnetic Resonance System=== | ||
− | The polarization of the target material during the experiment was monitored using Nuclear Magnetic Resonance (NMR) techniques. The technique | + | The polarization of the target material during the experiment was monitored using Nuclear Magnetic Resonance (NMR) techniques. The technique relies on detecting nuclear magnetic spin transitions. The rate of transitions is related to the population difference of the energy levels giving information on the original target polarization. The magnetization of the sample, of volume <math>V</math>, with <math>N</math> spins, each with <math>I</math> spin value is <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". ''Nucl. Instr. Meth'' '''A 427/3''', 440-454</ref> <br> |
− | <math>\vec{M} = N_{g\mu_{N}}IP_{I} = {\Sigma_{i}}^{N} \frac{\vec{\mu}_{i}}{V}</math><br> | + | {| border="0" style="background:transparent;" align="center" |
− | When the external magnetic field is placed perpendicularly under a rotating resonance frequency field with amplitude and frequency of <math>\vec{B}_{1}</math> and <math>\omega</math> respectively, the nuclear Zeeman transitions are induced in the target material. The rate of these transitions allows | + | |- |
− | "A measurement of the ratio of the strengths of the NMR signal with and without RF applied gives the polarization of the target relative to the calculable thermal equilibrium (TE) polarization." The polarization of protons (the spin <math>1/2</math>) and | + | | |
− | + | <math>\vec{M} = N_{g\mu_{N}}IP_{I} = {\Sigma_{i}}^{N} \frac{\vec{\mu}_{i}}{V}</math> | |
+ | |}<br> | ||
+ | When the external magnetic field is placed perpendicularly under a rotating resonance frequency field with amplitude and frequency of <math>\vec{B}_{1}</math> and <math>\omega</math> respectively, the nuclear Zeeman transitions are induced in the target material. The rate of these transitions allows a measurement of the target polarization. The current in the coil, that surrounds the target generates an oscillating resonance frequency. The absorption or emission of energy by the coil (energy gain or loss in the resonance circuit) indicates the sign of the target polarization.<br> | ||
+ | "A measurement of the ratio of the strengths of the NMR signal with and without RF applied gives the polarization of the target relative to the calculable thermal equilibrium (TE) polarization."<ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". ''Nucl. Instr. Meth'' '''A 427/3''', 440-454</ref> The polarization of protons (the spin <math>1/2</math>) and deuterons at thermal equilibrium are given as<br> | ||
+ | {| border="0" style="background:transparent;" align="center" | ||
+ | |- | ||
+ | | | ||
<math>P_{TE}^{p} = tanh(\frac{\mu_{p}B}{k_{B}T})</math> | <math>P_{TE}^{p} = tanh(\frac{\mu_{p}B}{k_{B}T})</math> | ||
− | + | |}<br> | |
− | and | + | and<br> |
− | + | {| border="0" style="background:transparent;" align="center" | |
+ | |- | ||
+ | | | ||
<math>P_{TE}^{ND3} = \frac{4tanh(\mu_{d}B/2k_{B}T)}{(3 + tanh^{2}(\mu_dB/2k_{B}T))}</math> | <math>P_{TE}^{ND3} = \frac{4tanh(\mu_{d}B/2k_{B}T)}{(3 + tanh^{2}(\mu_dB/2k_{B}T))}</math> | ||
− | + | |}<br> | |
− | where <math>k_{B}</math> is the Boltzmann constatnt, <math>B</math> - external magnetic field, <math>\mu_{p}</math> (<math>\mu_{d}</math>) - proton (deuteron) magnetic moment and <math>T</math> - temperature. During the experiment, the target polarization using NMR was measured via Q-meters of the Liverpool-type. It measures the voltage and related power gain or loss in the coil as a function of the input frequency. The Q-meter circuit is powered by a generator which sweeps the RF frequency through the Larmor frequency of the target. The inductance of the coil changes when the target absorbs or emits energy, producing the impedance change of circuit. The impedance change is related to the circuit voltage output. After accounting for the background measurement of the Q-meter for the input frequency and calibrating the system via the Thermal Equilibrium measurements, the target polarization is extracted. | + | where <math>k_{B}</math> is the Boltzmann constatnt, <math>B</math> - external magnetic field, <math>\mu_{p}</math> (<math>\mu_{d}</math>) - proton (deuteron) magnetic moment and <math>T</math> - temperature. During the experiment, the target polarization using NMR was measured via Q-meters of the Liverpool-type. It measures the voltage and related power gain or loss in the coil as a function of the input frequency. The Q-meter circuit is powered by a generator which sweeps the RF frequency through the Larmor frequency of the target. The inductance of the coil changes when the target absorbs or emits energy, producing the impedance change of circuit. The impedance change is related to the circuit voltage output. After accounting for the background measurement of the Q-meter for the input frequency and calibrating the system via the Thermal Equilibrium measurements, the target polarization is extracted. The NMR technique was only used to monitor the target polarization during the experiment, a final measurement of the polarization relied on measuring the exclusive (quasi-)elastic scattering asymmetry.<br> |
===The Target Chamber=== | ===The Target Chamber=== | ||
− | The target chamber is placed at the top of the cryostat. The chamber is filled with | + | The target chamber is placed at the top of the cryostat. The chamber is filled with <math>LHe</math> to keep the target material cool. It contains four target cells that are positioned using an aluminum target ladder structure. The cells are made of plastic material (polychlorotrifluoroethylene(PCTFE)) with a wall thickness of <math>0.2 mm</math>, in order to minimize the amount of material. The target cells are <math>1.5 cm</math> in diameter and <math>1 cm</math> in length. The PCTFE material was chosen for its high resistance to radiation damage and for the absence of hydrogen. The aluminum structure is connected to a brass disk minimizing the heat load due to radiation. In order to reduce the thermal conductivity along the target chamber, a teflon block was placed between the aluminum structure and the brass disk. The disk itself is connected to the top flange by a threaded stainless steel rod. The stainless steel rod is attached to the stepping motor <ref name="Prok2004"> Prok, Y. A. (2004). ''Measurement of The Spin Structure Function <math>g_{1}(x,Q^{2})</math> of The Proton in The Resonance Region''. Doctoral dissertation. University of Virginia, Richmond, VA.</ref>. <br> |
{| border="0" style="background:transparent;" align="center" | {| border="0" style="background:transparent;" align="center" | ||
|- | |- | ||
Line 79: | Line 60: | ||
[[File:TargetInsert.jpg|400px|thumb|Schematic of the Target Insert.]] | [[File:TargetInsert.jpg|400px|thumb|Schematic of the Target Insert.]] | ||
|}<br> | |}<br> | ||
− | During the | + | During the experiment, two of the target cells were filled with <math>NH3</math> and <math>ND3</math>, a third cell with a <math>2.3 mm</math> thick graphite disk, and the last cell was left empty. The <math>NH3</math> and <math>ND3</math> targets were used for physics measurements, while the carbon and the empty cells for background measurements. The desired target cell can be placed along the beam axis using a stepping motor. The NMR coils were wrapped around the outside surface of the cells. The coils, a <math>0.15 mm</math> in diameter <math>CuNi</math> tubing, were shaped rectangularly. Only one loop of NMR coils was used for the <math>NH3</math> target, while the <math>ND3</math> target required four loops to measure the polarization. Temperature sensors were located at several places of the target chamber and heater coils were attached below each target cell for annealing. |
+ | |||
+ | ==Polarized Target Materials== | ||
+ | |||
+ | [[File:O_Rondon_NuclearCorrectionsforpolarizedtargets.pdf]] | ||
+ | |||
+ | A polarized solid target's limited resistance to radiation damage is one of the remaining challenges for using polarized targets in scattering experiments. At present, solid ammonia and lithium deuteride are the target materials with the highest resistance to radiation damage<ref name="Baum1996"> Baum G, et al. A proposal for a Common Muon and Proton Apparatus for Structure and spectroscopy, CERN/SPSLC/96-14(1996).</ref>. . For EG1b experiment, ammonia targets were selected because of their ability to produce high polarization and be resistant to high radiation dose caused by the incident electron beam. Another advantage of ammonia target is a high ratio of free nucleons (~3/18), approximately 16.7 % for <math>^{15}NH_3</math> and 28.6% for <math>^{15}ND_3</math>. One disadvantage of choosing ammonia is the polarization background caused by <math>^{15}N</math>(spin - 1/2), or <math>^{14}N</math>(spin - 1), which was accounted for by taking data using a solid <math>^{15}N</math> target <ref name="Keith2003"> Keith, C. D., et al. (2003). A Polarized target for the CLAS detector. ''NIM, A''(501), 327-339. 327-339.</ref> <ref name="Chen2006">Chen, S. (2006). ''First Measurement of Deeply Virtual Compton Scattering with a Polarized Proton Target''. Doctoral dissertation. Florida State University, Tallahasee, FL. </ref>. The main target materials used for the EG1b experiment were frozen ammonia, <math>^{15}NH_3</math>, for the polarized protons and deuterated ammonia, <math>^{15}ND_3</math> for the polarized deuterons. In addition to <math>^{15}ND_3</math> and <math>^{15}NH_3</math> targets, <math>C_{12}</math>, liquid <math>He^4</math> and solid <math>N_{15}</math> were used to estimate the dilution of the data by background noise which can be attributed to the interaction of the incident electron with the Nitrogen or Helium nucleons present in the target cell. This estimate is referred to as a dilution factor <ref name="Keith2003"> Keith, C. D., et al. (2003). A Polarized target for the CLAS detector. ''NIM, A''(501), 327-339. 327-339.</ref> .<br> | ||
+ | {| border="0" style="background:transparent;" align="center" | ||
+ | |- | ||
+ | | | ||
+ | [[File:PolarizedTargetInTheCLASDetector.png|400px|thumb|EG1b Polarized Target in The CLAS Detector.]] | ||
+ | |}<br> | ||
+ | The target materials for the EG1b experiment were prepared by slowly freezing ammonia gas at <math>77 K</math> and crushing the solid ammonia small pieces of 1 - 3 mm in diameter at the Polarized Target Lab of the University of Virginia Physics Department. This design of the target helps to cool it effectively using liquid helium. Free electrons are introduced into the frozen ammonia by irradiating it with an electron beam depositing a dose of <math>10^{17} electrons/cm^{2}</math> at a temperature near <math>80 K</math>.<ref name="CLASNOTE9004">Burkert, V., Mecking, B., Day, D., McCarthy, J., Minehart, R. Polarized Target Experiments Using the CEBAF Large Acceptance Spectrometer. CLAS - Note 90 - 04.</ref>. Dynamic Nuclear Polarization, explained below, uses the free electrons to polarize the nucleii in the target. During the experiment, the polarized target is slowly damaged in the electron beam. This damage can be repaired by warming the target material to <math>80 K</math> for NH3 and higher for ND3. During this annealing, free radicals (paramagnetic centers) produced at low temperatures are recombined, decreasing the number of paramagnetic centers. After repeating this process several times, the target material exhibits significant decrease in the polarization and has to be replaced. The polarized target granules change their color from grey to purple after radiation damage (Fig TargetPurple).<br> | ||
+ | {| border="0" style="background:transparent;" align="center" | ||
+ | |- | ||
+ | | | ||
+ | [[File:AmmoniaTarget.jpg|400px|thumb|EG1b target material after the radiation damage.]] | ||
+ | |}<br> | ||
+ | Dynamic Nuclear Polarization (DNP) is a process in which the polarization of free electrons is transferred to a nucleus<ref name="Chen2006">Chen, S. (2006). ''First Measurement of Deeply Virtual Compton Scattering with a Polarized Proton Target''. Doctoral dissertation. Florida State University, Tallahasee, FL. </ref> . In DNP the target is doped with paramagnetic impurities by chemical doping or by irradiating the target in an electron beam. For low temperatures, on the order of <math>0.5 K</math> and high magnetic fields on the order of 2.5 <math>\mbox{Tesla}</math>, the free electron polarization approaches 100%, on the other hand the protons inside the target are unpolarized. An applied microwave field with a frequency close to the electron spin resonance induces transitions which flip the spin of the electron and, because of the electron-nucleus hyperfine couping, a nearby nucleon. The relaxation time of the electron is <math>10^{-3} s</math>, whereas the relaxation time of the proton in the target is <math>10^3 s</math>. Due to such a big difference of the relaxation time of the proton and electron, the flipped electron spin rapidly returns to its thermal equilibrium state from where it induces a proton spin-flip again. As a result, the spin polarization is transferred to the protons after some time. The average beam-target polarization product for the EG1b experiment was <math>P_b \times P_t = (0.51 \pm 0.01)</math> and <math>P_b \times P_t = (0.19 \pm 0.03)</math> for the NH3 and ND3 targets respectively. <ref name="Dharmawardane2006"> Dharmawardane, K.V., et al., (The CLAS Collaboration). (2006). Measurement of the x and <math>Q^2</math>-Dependence of the Spin Asymmetry A1 on the Nucleon. ''Phys. Lett., B''(641), 11.</ref> <br> | ||
=The CEBAF Large Acceptance spectrometer= | =The CEBAF Large Acceptance spectrometer= | ||
+ | ==Introduction== | ||
+ | The CEBAF Large Acceptance Spectrometer (CLAS), located in Jefferson Lab's Hall B, was used to measure the final state particles resulting from the scattering of a polarized electron by a polarized nucleon. The CLAS uses six superconducting coils to establish a toroidal magnetic field encircling the incident electron's momentum direction. A set of three drift chambers are positioned to determine the trajectories of particles which pass through the 6 gaps between the magnet coils. The first drift chamber, Region 1 (R1), is placed at the entrance to the magnetic coil. A second chamber, Region 2 (R2), is placed in the center of the coils. The final chamber, Region 3 (R3), measures charged particles leaving the toroidal field. A total of 18 drift chambers are available to reconstruct the trajectory of charged particles passing through the magnetic field. After the drift chamber system, the CLAS detector is equipped with a Cherenkov counter for separating electrons from pions and with scintillators, to determine the time of flight of a charged particle. An electromagnetic calorimeter is placed at the exit of the detector to detect neutral particles and improve the detector's ability to distinguish between electrons and hadrons.<br> | ||
+ | {| border="0" style="background:transparent;" align="center" | ||
+ | |- | ||
+ | | | ||
+ | [[File:The_CEBAF_Large_Acceptance_Spectrometer_at_Jefferson_Lab.jpg|400px|thumb|The CEBAF Large Acceptance spectrometer.]] | ||
+ | |}<br> | ||
==The Torus Magnet== | ==The Torus Magnet== | ||
− | The CLAS's torus magnet consists of six superconducting coils located around the beam line in a toroidal geometry, producing a magnetic field in the <math>\varphi</math> direction when the z-axis of a spherical coordinate system is aligned with the incident beam direction. A sector is defined based on the boundaries of each magnetic coil resulting in a total of six sectors. The maximum current for the CLAS magnet is 2860 Amps corresponding to a total magnetic field in the forward direction of 2.5 T-m and 0.6 T at a polar scattering angle of 90 degrees. The magnet itself is around 5 m in diameter and 5 m in length. The coils of the magnet are cooled by liquid helium circulating through cooling tubes at the magnet's superconducting temperature of 4.5 K <ref name="Prok2004"> Prok, Y. A. (2004). ''Measurement of The Spin Structure Function <math>g_{1}(x,Q^{2})</math> of The Proton in The Resonance Region''. Doctoral dissertation. University of Virginia, Richmond, VA.</ref>. A charged particle's momentum is determined by the radius of curvature through the magnetic field to a resolution of <math>\Delta p/p</math> from 0.5% to 1% <ref name="Fatemi2002">Fatemi, R. H. (2002). ''The Spin Structure of The Proton in The Resonance Region''. Doctoral dissertation. University of Virginia, Sterling, VA. </ref>. In the EG1b experiment, the operated torus values were: 2250, -2250, 1500, -1500 Amps. | + | The CLAS's torus magnet consists of six superconducting coils located around the beam line in a toroidal geometry, producing a magnetic field in the <math>\varphi</math> direction when the z-axis of a spherical coordinate system is aligned with the incident beam direction. A sector is defined based on the boundaries of each magnetic coil resulting in a total of six sectors. The maximum current for the CLAS magnet is <math>2860 Amps</math> corresponding to a total magnetic field in the forward direction of <math>2.5 T-m</math> and <math>0.6 T</math> at a polar scattering angle of <math>90</math> degrees. The magnet itself is around 5 m in diameter and <math>5 m</math> in length. The coils of the magnet are cooled by liquid helium circulating through cooling tubes at the magnet's superconducting temperature of <math>4.5 K</math> <ref name="Prok2004"> Prok, Y. A. (2004). ''Measurement of The Spin Structure Function <math>g_{1}(x,Q^{2})</math> of The Proton in The Resonance Region''. Doctoral dissertation. University of Virginia, Richmond, VA.</ref>. A charged particle's momentum is determined by the radius of curvature through the magnetic field to a resolution of <math>\Delta p/p</math> from <math>0.5%</math> to <math>1%</math> <ref name="Fatemi2002">Fatemi, R. H. (2002). ''The Spin Structure of The Proton in The Resonance Region''. Doctoral dissertation. University of Virginia, Sterling, VA. </ref>. In the EG1b experiment, the operated torus values were: <math>2250</math>, <math>-2250</math>, <math>1500</math>, <math>-1500 Amps</math>.<br> |
− | + | {| border="0" style="background:transparent;" align="center" | |
− | [[File:TorusMagnet.jpg| | + | |- |
− | + | | | |
− | + | [[File:TorusMagnet.jpg|400px|thumb|CLAS Torus Magnet.]] | |
+ | |}<br> | ||
==Drift Chambers== | ==Drift Chambers== | ||
− | The drift chamber system in the CLAS detector is divided into three regions, each consisting of six separate chambers(sectors). The drift chambers contain three types of wires stretched between the endplates: sense, guard and field. The end plates are attached to the drift chamber so that the angle they form is equal to 60 degrees. Each drift chamber is subdivided into two separate superlayers. Each superlayer has six layers of drift cells. Each drift cell has one sense wire and is surrounded by six field wires forming a hexagonal shape. Each superlayer is surrounded by guard wires at a positive potential to complete the cell symmetry establishing a radial electric field within the drift cells. The sense wire is operated at positive potential and the field wire at negative. In each superlayer the distance between the sense and field wire increases with the radial distance from the target. In R1 the average distance between the sense and field is 0.7 cm, in R2 1.15 cm, and in R3 2.0 cm <ref name="Metayer2000"> Mestayer, M. D., et. al. (2000). The CLAS drift chamber system. ''NIM, A''(449), 81-111.</ref> . The CLAS drift chamber gas is a 90 - 10% mixture of the argon(Ar) and <math>CO_2</math>, where Ar has an ionization gain of <math>~ 10^4</math>. Inside the drift chamber, a constant pressure is provided by outflowing the gas. The chamber end plates have a circuit board with a single channel differential pre-amplifier for each sense wire. | + | The drift chamber system in the CLAS detector is divided into three regions, each consisting of six separate chambers(sectors). The drift chambers contain three types of wires stretched between the endplates: sense, guard and field. The end plates are attached to the drift chamber so that the angle they form is equal to 60 degrees. Each drift chamber is subdivided into two separate superlayers. Each superlayer has six layers of drift cells. Each drift cell has one sense wire and is surrounded by six field wires forming a hexagonal shape. Each superlayer is surrounded by guard wires at a positive potential to complete the cell symmetry establishing a radial electric field within the drift cells. The sense wire is operated at positive potential and the field wire at negative. In each superlayer the distance between the sense and field wire increases with the radial distance from the target. In R1 the average distance between the sense and field is 0.7 cm, in R2 1.15 cm, and in R3 2.0 cm <ref name="Metayer2000"> Mestayer, M. D., et. al. (2000). The CLAS drift chamber system. ''NIM, A''(449), 81-111.</ref> . The CLAS drift chamber gas is a 90 - 10% mixture of the argon(Ar) and <math>CO_2</math>, where Ar has an ionization gain of <math>~ 10^4</math>. Inside the drift chamber, a constant pressure is provided by outflowing the gas. The chamber end plates have a circuit board with a single channel differential pre-amplifier for each sense wire.<br> |
− | + | The drift chamber system is used to track charged particles. A drift chamber is a particle tracking detector that measures the drift time of liberated electrons in a gas to calculate the spacial position of the ionizing particle. <br> | |
− | The drift chamber system is used to track charged particles. A drift chamber is a particle tracking detector that measures the drift time of liberated electrons in a gas to calculate the spacial position of the ionizing particle. | + | {| border="0" style="background:transparent;" align="center" |
− | + | |- | |
− | + | | | |
− | [[File:DriftChamber.jpg| | + | [[File:DriftChamber.jpg|400px|thumb|A charged particle passing through two superlayers of the drift chamber.]] |
− | + | |}<br> | |
− | |||
An electric field in a drift chamber is produced by the anode(sense) and cathode(field) wires. A charged particle traveling through the drift chamber ionizes the gas, freeing electrons that drift to the anodes. After a drift time $(\delta t)$, electrons are collected at the anode(sense wire) generating a pulse for the time measurement. The distance of the traversing particle from the known position of the sense wire can be calculated using the drift time and drift velocity. | An electric field in a drift chamber is produced by the anode(sense) and cathode(field) wires. A charged particle traveling through the drift chamber ionizes the gas, freeing electrons that drift to the anodes. After a drift time $(\delta t)$, electrons are collected at the anode(sense wire) generating a pulse for the time measurement. The distance of the traversing particle from the known position of the sense wire can be calculated using the drift time and drift velocity. | ||
==Cherenkov detector== | ==Cherenkov detector== | ||
− | The threshold CLAS Cherenkov detector is used to distinguish electrons from pions. The gas mixture used to fill the Cherenkov counter is perfluorobutane <math>C_4 F_{10}</math> gas at atmospheric pressure. The advantage of perfluorobutane <math>C_4 F_{10}</math> gas is its high index of refraction n=1.00153, which results in a high photon yield. The threshold for Cerenkov radiation can be written as <math>v>c/n</math>, or for energies <math>E>\gamma \times m</math>, where v is the charged particle velocity, n the index of refraction for the medium, c the speed of light and <math>\gamma = \frac{1}{\sqrt{1 - \frac{1}{n^2}}}</math>. In our case <math>\gamma = 18.098</math>. Accordingly, one can calculate the energy threshold for different charged particles; for electrons it is 9 MeV and for pions 2.5 GeV. The Cherenkov detector was designed to maximize the coverage in each of the sectors up to an angle <math>\theta=45</math> degrees <ref name="Adams2001"> Adams, G., Burkert, V. D., et al. (The CLAS Collaboration). (2001). The CLAS Cherenkov Detector. ''NIM, A''(465), 414-427. </ref> . | + | The threshold CLAS Cherenkov detector is used to distinguish electrons from pions. The gas mixture used to fill the Cherenkov counter is perfluorobutane <math>C_4 F_{10}</math> gas at atmospheric pressure. The advantage of perfluorobutane <math>C_4 F_{10}</math> gas is its high index of refraction n=1.00153, which results in a high photon yield. The threshold for Cerenkov radiation can be written as <math>v>c/n</math>, or for energies <math>E>\gamma \times m</math>, where v is the charged particle velocity, n the index of refraction for the medium, c the speed of light and <math>\gamma = \frac{1}{\sqrt{1 - \frac{1}{n^2}}}</math>. In our case <math>\gamma = 18.098</math>. Accordingly, one can calculate the energy threshold for different charged particles; for electrons it is 9 MeV and for pions 2.5 GeV. The Cherenkov detector was designed to maximize the coverage in each of the sectors up to an angle <math>\theta=45</math> degrees <ref name="Adams2001"> Adams, G., Burkert, V. D., et al. (The CLAS Collaboration). (2001). The CLAS Cherenkov Detector. ''NIM, A''(465), 414-427. </ref> .<br> |
− | + | {| border="0" style="background:transparent;" align="center" | |
− | [[File:CherenkovCounter.jpg| | + | |- |
− | + | | | |
− | Light is collected using a system of mirrors to focus the light onto cones which are connected to the Phillips XP4500B type photomultiplier tubes(PMTs). | + | [[File:CherenkovCounter.jpg|400px|thumb|One module of the Cherenkov Counter.]] |
− | In the extreme regions of the spectrometer's angular acceptance, the number of detected photoelectrons is too low. Additional photomultiplier tubes were placed in these regions to compensate for the low photoelectron detection efficiency | + | |}<br> |
+ | Light is collected using a system of mirrors to focus the light onto cones, which are connected to the Phillips XP4500B type photomultiplier tubes(PMTs). | ||
+ | In the extreme regions of the spectrometer's angular acceptance, the number of detected photoelectrons is too low. Additional photomultiplier tubes were placed in these regions to compensate for the low photoelectron detection efficiency. | ||
==Scintillators== | ==Scintillators== | ||
− | The CLAS is equipped with 288 scintillator counters. The scintillators are used to determine the time of flight for a charged particle and to determine coincidences between particles. The time of flight system has a time resolution at small polar angles of <math>\Delta t =120</math>ps and <math>\Delta t=250</math>ps at angles above 90 degrees. This time resolution helps discriminate between pions and kaons up to 2 GeV/c. The time of flight system is located between the Cherenkov detectors and the electromagnetic calorimeters. The scintillator paddles are made from BC_408 <ref name="Adams2001"> Adams, G., Burkert, V. D., et al. (The CLAS Collaboration). (2001). The CLAS Cherenkov Detector. ''NIM, A''(465), 414-427. </ref>, are located perpendicular to the average particle trajectory, and have an angular polar coverage of 1.5 degrees each. Each sector of the CLAS detector consists of 48 scintillator paddles with a thickness of 5.08 cm. The length of the scintillators varies from 30 cm to 450 cm and the width is between 15 cm at small polar angles and 22 cm for the large angles <ref name="Smith1999">E.S. Smith, T. Carstens, J. Distelbrink, M. Eckhause, H. Egiyan, L. Elouadrhiri, J. Ficenec, M. Guidal, A.D. Hancock, F.W. Hersman, M. Holtrop, D.A. Jenkins, W. Kim, K. Loukachine, K. MacArthur, C. Marchand, B. Mecking, G. Mutchler, D. Schutt, L.C. Smith, T.P. Smith, S. Taylor, T.Y. Tung, A. Weisenberger, R.E. Welsh (1999). The time-of-flight system for CLAS. ''NIM, A''(432), 265–298. </ref> . | + | The CLAS is equipped with 288 scintillator counters. The scintillators are used to determine the time of flight for a charged particle and to determine coincidences between particles. The time of flight system has a time resolution at small polar angles of <math>\Delta t =120</math>ps and <math>\Delta t=250</math>ps at angles above 90 degrees. This time resolution helps discriminate between pions and kaons up to 2 GeV/c. The time of flight system is located between the Cherenkov detectors and the electromagnetic calorimeters. The scintillator paddles are made from BC_408 <ref name="Adams2001"> Adams, G., Burkert, V. D., et al. (The CLAS Collaboration). (2001). The CLAS Cherenkov Detector. ''NIM, A''(465), 414-427. </ref>, are located perpendicular to the average particle trajectory, and have an angular polar coverage of 1.5 degrees each. Each sector of the CLAS detector consists of 48 scintillator paddles with a thickness of 5.08 cm. The length of the scintillators varies from 30 cm to 450 cm and the width is between 15 cm at small polar angles and 22 cm for the large angles <ref name="Smith1999">E.S. Smith, T. Carstens, J. Distelbrink, M. Eckhause, H. Egiyan, L. Elouadrhiri, J. Ficenec, M. Guidal, A.D. Hancock, F.W. Hersman, M. Holtrop, D.A. Jenkins, W. Kim, K. Loukachine, K. MacArthur, C. Marchand, B. Mecking, G. Mutchler, D. Schutt, L.C. Smith, T.P. Smith, S. Taylor, T.Y. Tung, A. Weisenberger, R.E. Welsh (1999). The time-of-flight system for CLAS. ''NIM, A''(432), 265–298. </ref> .<br> |
− | + | {| border="0" style="background:transparent;" align="center" | |
− | + | |- | |
− | [[File:TOF.jpg| | + | | |
+ | [[File:TOF.jpg|400px|thumb|Time-of-Flight system for CLAS.]] | ||
+ | |}<br> | ||
==Calorimeter== | ==Calorimeter== | ||
− | |||
The CLAS detector contains 8 electromagnetic calorimeter modules. A calorimeter measures the total energy deposited by a particle that enters the detectors acceptance. Calorimeters are sensitive neutral particles with sufficient energy to generate showers and can be used to distinguish between the energy deposited by electrons and hadrons. The CLAS calorimeter has three main functions:<br> | The CLAS detector contains 8 electromagnetic calorimeter modules. A calorimeter measures the total energy deposited by a particle that enters the detectors acceptance. Calorimeters are sensitive neutral particles with sufficient energy to generate showers and can be used to distinguish between the energy deposited by electrons and hadrons. The CLAS calorimeter has three main functions:<br> | ||
− | + | * Detection of electrons at energies above 0.5 GeV;<br> | |
− | + | * Detection of photons with energies higher than 0.2 GeV;<br> | |
− | + | * Detection of neutrons, with discrimination between photon and neutrons using time-of-flight techniques.<br> | |
− | + | {| border="0" style="background:transparent;" align="center" | |
− | + | |- | |
− | [[File:CLASCalorimeter.jpg| | + | | |
− | + | [[File:CLASCalorimeter.jpg|400px|thumb|One module of electromagnetic calorimeter.]] | |
− | + | |}<br> | |
Calorimeter detectors are placed in the forward region of each sector that span polar angles of 10-45 degrees. Two additional calorimeters are located in sectors 1 and 2 that span polar angles of 50 to 70 degrees. The forward calorimeter has a lead/scintillator thickness ratio of 0.2, with 40 cm of scintillators and 8 cm of lead per module. The lead-scintillator sandwich is shaped to form an equilateral triangle in order to match the hexagonal geometry of the CLAS detector. Each scintillator layer contains 36 paddles parallel to one side of the triangle, with this configuration each orientation is rotated by 120 degrees from each other. This gives three views, each containing 13 layers providing stereo information locating the energy deposition. There is a longitudinal sampling of the shower to improve hadron identification. Each set of 13 layers are subdivided into 5 inner layers and 8 outer layers. | Calorimeter detectors are placed in the forward region of each sector that span polar angles of 10-45 degrees. Two additional calorimeters are located in sectors 1 and 2 that span polar angles of 50 to 70 degrees. The forward calorimeter has a lead/scintillator thickness ratio of 0.2, with 40 cm of scintillators and 8 cm of lead per module. The lead-scintillator sandwich is shaped to form an equilateral triangle in order to match the hexagonal geometry of the CLAS detector. Each scintillator layer contains 36 paddles parallel to one side of the triangle, with this configuration each orientation is rotated by 120 degrees from each other. This gives three views, each containing 13 layers providing stereo information locating the energy deposition. There is a longitudinal sampling of the shower to improve hadron identification. Each set of 13 layers are subdivided into 5 inner layers and 8 outer layers. | ||
Line 137: | Line 146: | ||
[[Delta_D_over_D]] | [[Delta_D_over_D]] | ||
+ | |||
+ | [https://wiki.iac.isu.edu/index.php/SIDIS_PionAsym_EG2000 Go Back] |
Latest revision as of 06:47, 10 December 2012
Target
Introduction
Polarized targets and polarized beams are recently acquired research tools being used to investigate the spin structure of the nucleon. Inclusive scattering experiments using polarized targets and beams facilitate measurements of observables exhibiting spin degrees of freedom, like the spin structure of the nucleon, the electromagnetic structure of the nucleon in its ground state, etc. <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". Nucl. Instr. Meth A 427/3, 440-454</ref> The technology producing targets containing polarized nucleons have been developed over the past 50 years. For the experiments using electrons as probes, due to the small cross section of the electromagnetic interactions, one of the requirements for polarized targets are a large thickness and resistance to the electron beam intensity without significant radiation damage. The solid targets for the EG1B experiment were polarized via the Dynamic Nuclear Polarization (DNP) method<ref name="CrabbMeyer1997"> Crabb, D.G., Meyer, W.(1997). "Solid Polarized Targets for Nuclear and Particle Physics Experiments". Annu. Rev. Nucl. Part. Sci 47, 67-109</ref>.
EG1b polarized target system consists the following main components: the superconducting Helmholtz coils to reach 5 T magnetic field, the evaporation refrigerator for target cooling, the microwaves to induce spin flip in the target, NMR system measuring the target polarization and the housing for the solid target <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". Nucl. Instr. Meth A 427/3, 440-454</ref>.
Target Magnet
A 5 T magnetic field is established using a pair of superconducting Helmholtz coils made out of Niobium-Titanium mixture with a critical temperature of 9 K. The magnet becomes superconducting below its critical temperature. In order to establish a current in the coils, a section of the magnetic is warmed above its critical temperature. This process is called "magnet energization". After the coils have been energized, the "magnet switch" section of the coils is cooled down and the current in the leads is ramped down. The full current of the magnet is carried by the superconducting Helmholtz coils.
The superconducting coils are oriented such that the magnetic field is parallel to the incident beam direction. The field induces the hyperfine splittings needed to polarize the target material using 140 Ghz RF wave. The uniformity of the field varies less than
over a cylindrical volume of 20 mm in diameter and length. This configuration is necessary for DNP. The particles with scattering angles between 0-50 degrees are detected in the CLAS as well as 75-105 degrees. The Helmholtz coils block particles scattering between 50 and 75 degrees. The target magnetic field does not interact with the electron beam, however, it is effective in shielding the drift chambers from low energy Moller electrons. The target field bends scattered particles in the azimuthal direction and falls rapidly with distance as ( ). The effect of the magnetic field on the drift chambers is negligible <ref name="Chen2006">Chen, S. (2006). First Measurement of Deeply Virtual Compton Scattering with a Polarized Proton Target. Doctoral dissertation. Florida State University, Tallahasee, FL. </ref> .The Evaporation Refrigerator
The target material is located at the center of the magnet in a separate chamber, called the banjo. Cooling the target to approximately 1 K was achieved using a
evaporation refrigerator inserted through a 20 cm diameter pumping tube. The pumping tube connects the banjo and the pumping system. The components of the refrigerator are the sintered copper separator pot, two series of heat exchangers, and two lines that supply helium to the banjo. The phase separator allows the liquid to pass, but blocks the helium vapor. The helium vapor is pumped away to cool the radiation baffles. The liquid in the phase separator is directed to the banjo one of the two lines. The heat exchangers remotely controlled by needle valves. The presence of the liquid helium in the target chamber cools target material effectively <ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". Nucl. Instr. Meth A 427/3, 440-454</ref> .The Microwave System
The 140 GHz microwave used for DNP are supplied by the Extended Interaction Oscillator (EIO) tube providing
Microwaves are delivered to the target material using a rectangular gold-plated wave guide located outside the cryostat and a tube made out of inside the wave guide system. The tube and the wave guide are connected by a rectangular-circular adapter. This allows microwaves to travel through the tube and into the rectangular segment of the wave guides suppling microwaves to the desired target cell during the experiment <ref name="Prok2004"> Prok, Y. A. (2004). Measurement of The Spin Structure Function of The Proton in The Resonance Region. Doctoral dissertation. University of Virginia, Richmond, VA.</ref>.
The Nuclear Magnetic Resonance System
The polarization of the target material during the experiment was monitored using Nuclear Magnetic Resonance (NMR) techniques. The technique relies on detecting nuclear magnetic spin transitions. The rate of transitions is related to the population difference of the energy levels giving information on the original target polarization. The magnetization of the sample, of volume
|
When the external magnetic field is placed perpendicularly under a rotating resonance frequency field with amplitude and frequency of
"A measurement of the ratio of the strengths of the NMR signal with and without RF applied gives the polarization of the target relative to the calculable thermal equilibrium (TE) polarization."<ref name="Averett1999"> T.D. Averett et al. (1999). "A solid polarized target for high-luminosity experiments". Nucl. Instr. Meth A 427/3, 440-454</ref> The polarization of protons (the spin ) and deuterons at thermal equilibrium are given as
|
and
|
where
The Target Chamber
The target chamber is placed at the top of the cryostat. The chamber is filled with
During the experiment, two of the target cells were filled with
and , a third cell with a thick graphite disk, and the last cell was left empty. The and targets were used for physics measurements, while the carbon and the empty cells for background measurements. The desired target cell can be placed along the beam axis using a stepping motor. The NMR coils were wrapped around the outside surface of the cells. The coils, a in diameter tubing, were shaped rectangularly. Only one loop of NMR coils was used for the target, while the target required four loops to measure the polarization. Temperature sensors were located at several places of the target chamber and heater coils were attached below each target cell for annealing.Polarized Target Materials
File:O Rondon NuclearCorrectionsforpolarizedtargets.pdf
A polarized solid target's limited resistance to radiation damage is one of the remaining challenges for using polarized targets in scattering experiments. At present, solid ammonia and lithium deuteride are the target materials with the highest resistance to radiation damage<ref name="Baum1996"> Baum G, et al. A proposal for a Common Muon and Proton Apparatus for Structure and spectroscopy, CERN/SPSLC/96-14(1996).</ref>. . For EG1b experiment, ammonia targets were selected because of their ability to produce high polarization and be resistant to high radiation dose caused by the incident electron beam. Another advantage of ammonia target is a high ratio of free nucleons (~3/18), approximately 16.7 % for
The target materials for the EG1b experiment were prepared by slowly freezing ammonia gas at
Dynamic Nuclear Polarization (DNP) is a process in which the polarization of free electrons is transferred to a nucleus<ref name="Chen2006">Chen, S. (2006). First Measurement of Deeply Virtual Compton Scattering with a Polarized Proton Target. Doctoral dissertation. Florida State University, Tallahasee, FL. </ref> . In DNP the target is doped with paramagnetic impurities by chemical doping or by irradiating the target in an electron beam. For low temperatures, on the order of
The CEBAF Large Acceptance spectrometer
Introduction
The CEBAF Large Acceptance Spectrometer (CLAS), located in Jefferson Lab's Hall B, was used to measure the final state particles resulting from the scattering of a polarized electron by a polarized nucleon. The CLAS uses six superconducting coils to establish a toroidal magnetic field encircling the incident electron's momentum direction. A set of three drift chambers are positioned to determine the trajectories of particles which pass through the 6 gaps between the magnet coils. The first drift chamber, Region 1 (R1), is placed at the entrance to the magnetic coil. A second chamber, Region 2 (R2), is placed in the center of the coils. The final chamber, Region 3 (R3), measures charged particles leaving the toroidal field. A total of 18 drift chambers are available to reconstruct the trajectory of charged particles passing through the magnetic field. After the drift chamber system, the CLAS detector is equipped with a Cherenkov counter for separating electrons from pions and with scintillators, to determine the time of flight of a charged particle. An electromagnetic calorimeter is placed at the exit of the detector to detect neutral particles and improve the detector's ability to distinguish between electrons and hadrons.
The Torus Magnet
The CLAS's torus magnet consists of six superconducting coils located around the beam line in a toroidal geometry, producing a magnetic field in the
Drift Chambers
The drift chamber system in the CLAS detector is divided into three regions, each consisting of six separate chambers(sectors). The drift chambers contain three types of wires stretched between the endplates: sense, guard and field. The end plates are attached to the drift chamber so that the angle they form is equal to 60 degrees. Each drift chamber is subdivided into two separate superlayers. Each superlayer has six layers of drift cells. Each drift cell has one sense wire and is surrounded by six field wires forming a hexagonal shape. Each superlayer is surrounded by guard wires at a positive potential to complete the cell symmetry establishing a radial electric field within the drift cells. The sense wire is operated at positive potential and the field wire at negative. In each superlayer the distance between the sense and field wire increases with the radial distance from the target. In R1 the average distance between the sense and field is 0.7 cm, in R2 1.15 cm, and in R3 2.0 cm <ref name="Metayer2000"> Mestayer, M. D., et. al. (2000). The CLAS drift chamber system. NIM, A(449), 81-111.</ref> . The CLAS drift chamber gas is a 90 - 10% mixture of the argon(Ar) and
The drift chamber system is used to track charged particles. A drift chamber is a particle tracking detector that measures the drift time of liberated electrons in a gas to calculate the spacial position of the ionizing particle.
An electric field in a drift chamber is produced by the anode(sense) and cathode(field) wires. A charged particle traveling through the drift chamber ionizes the gas, freeing electrons that drift to the anodes. After a drift time $(\delta t)$, electrons are collected at the anode(sense wire) generating a pulse for the time measurement. The distance of the traversing particle from the known position of the sense wire can be calculated using the drift time and drift velocity.
Cherenkov detector
The threshold CLAS Cherenkov detector is used to distinguish electrons from pions. The gas mixture used to fill the Cherenkov counter is perfluorobutane
Light is collected using a system of mirrors to focus the light onto cones, which are connected to the Phillips XP4500B type photomultiplier tubes(PMTs). In the extreme regions of the spectrometer's angular acceptance, the number of detected photoelectrons is too low. Additional photomultiplier tubes were placed in these regions to compensate for the low photoelectron detection efficiency.
Scintillators
The CLAS is equipped with 288 scintillator counters. The scintillators are used to determine the time of flight for a charged particle and to determine coincidences between particles. The time of flight system has a time resolution at small polar angles of
Calorimeter
The CLAS detector contains 8 electromagnetic calorimeter modules. A calorimeter measures the total energy deposited by a particle that enters the detectors acceptance. Calorimeters are sensitive neutral particles with sufficient energy to generate showers and can be used to distinguish between the energy deposited by electrons and hadrons. The CLAS calorimeter has three main functions:
- Detection of electrons at energies above 0.5 GeV;
- Detection of photons with energies higher than 0.2 GeV;
- Detection of neutrons, with discrimination between photon and neutrons using time-of-flight techniques.
Calorimeter detectors are placed in the forward region of each sector that span polar angles of 10-45 degrees. Two additional calorimeters are located in sectors 1 and 2 that span polar angles of 50 to 70 degrees. The forward calorimeter has a lead/scintillator thickness ratio of 0.2, with 40 cm of scintillators and 8 cm of lead per module. The lead-scintillator sandwich is shaped to form an equilateral triangle in order to match the hexagonal geometry of the CLAS detector. Each scintillator layer contains 36 paddles parallel to one side of the triangle, with this configuration each orientation is rotated by 120 degrees from each other. This gives three views, each containing 13 layers providing stereo information locating the energy deposition. There is a longitudinal sampling of the shower to improve hadron identification. Each set of 13 layers are subdivided into 5 inner layers and 8 outer layers.
Notes
<references/>