Difference between revisions of "GEM Foil Cleaning Methods"

From New IAC Wiki
Jump to navigation Jump to search
 
(8 intermediate revisions by one other user not shown)
Line 11: Line 11:
  
 
The above info came from Alexis Rodrigues (Alexis.Rodrigues@cern.ch) . Alexis did not recommend the alcohol method.
 
The above info came from Alexis Rodrigues (Alexis.Rodrigues@cern.ch) . Alexis did not recommend the alcohol method.
 +
  
 
==Power Washers==
 
==Power Washers==
Line 21: Line 22:
  
 
http://www.amazon.com/AR-AR118-Electric-Pressure-Washer/dp/B003B6KQZE/ref=pd_sbs_ol_16
 
http://www.amazon.com/AR-AR118-Electric-Pressure-Washer/dp/B003B6KQZE/ref=pd_sbs_ol_16
 +
 +
manual
 +
 +
http://www.arblueclean.com/uploadfiles/image/file/AR118%20Operating%20Manual(1).pdf
  
 
==Clean room Ovens==
 
==Clean room Ovens==
 +
 +
Terra Universal: Class 100 Cleanroom Oven Cat# 3700-70  $8,992, 2.8 cu. ft.
 +
 +
 +
 +
  
 
http://www.memmert.com/products/cleanroom-drying-oven/cleanroomdryingoven-overview/
 
http://www.memmert.com/products/cleanroom-drying-oven/cleanroomdryingoven-overview/
Line 31: Line 42:
  
 
http://www.memmert.com/en/products/cleanroom-drying-oven/cleanroomdryingoven-models/models/UFP-500-RR/
 
http://www.memmert.com/en/products/cleanroom-drying-oven/cleanroomdryingoven-models/models/UFP-500-RR/
 +
 +
 +
http://www.blue-m.com/products/productdetails.aspx?tid=1&pscid=47&plid=85&src=gaw&gclid=CPi77Nukh6sCFYTt7QodQnEgMQ
 +
 +
 +
http://www.tedpella.com/ovens_html/ovens.htm#anchor1388
 +
 +
http://www.carbolite.us/cleanroomovens.html
 +
 +
http://www.despatch.com/industrial-ovens/benchtop-ovens-and-lab-ovens.aspx
 +
 +
==Warming tank==
 +
 +
A degreaser solution is stored at 60 celsius so foils can be dipped for 1 minute to clean the copper.
 +
 +
 +
check TerraUniversal Ultrasonic Cleaner with heating
 +
 +
2.5 gallon, cat #2619-00 $964.
 +
 +
Need a stainless steel tank to hold the solution and keep it warm
 +
 +
http://www.platingsales.com/electropolish.html
 +
 +
==Deionizers==
 +
 +
http://www.portablewaterdi.com/deionizers.php
 +
 +
==1600 PSI Electric Pressure Washer==
 +
 +
http://www.sears.com/shc/s/p_10153_12605_07175265000P?prdNo=4&blockNo=4&blockType=L4
  
 
=Brookhaven=
 
=Brookhaven=
Line 48: Line 90:
  
 
One should keep in mind that after this process the GEM impedance should drop dramatically, due to the conductivity of the remaining alcohol. However, usually after 5hrs of purging with dry gas, the impedance returns to its original value. "
 
One should keep in mind that after this process the GEM impedance should drop dramatically, due to the conductivity of the remaining alcohol. However, usually after 5hrs of purging with dry gas, the impedance returns to its original value. "
 +
 +
  
 
[https://wiki.iac.isu.edu/index.php/GEMS]
 
[https://wiki.iac.isu.edu/index.php/GEMS]

Latest revision as of 17:28, 10 October 2011

Method used at CERN

  1. When the leakage current is above 10 nA and below 200 nA when the GEM HV is 600 Volts, the GEMS are cleaned.
  2. First try high pressure (2000 PSI) distilled water (10 Mohms quality) spray. CERN has what looks like a power washer and they spay it against a tub wall in a workshop.
  3. After spraying with distilled water they bake it at 80 celsius in an oven for 1 hour
  4. If this doesn't work they will repeat the above after immersing the foil in a degreaser bath at 60 degrees celsius for 1 minute. Then rinse with a non pressure (not high pressure) spray of DI.
Ask RUI which degreaser he uses

When the leakage current is below 200 nA we just clean the GEMs with sprayed DI water (DI water 10Mohms quality)

The above info came from Alexis Rodrigues (Alexis.Rodrigues@cern.ch) . Alexis did not recommend the alcohol method.


Power Washers

Power washer similar to what RUI is using

http://www.amazon.com/Earthwise-PWO2200-Electric-Pressure-Washer/dp/B002MAPNEE

the smaller model below may be better for the LDS

http://www.amazon.com/AR-AR118-Electric-Pressure-Washer/dp/B003B6KQZE/ref=pd_sbs_ol_16

manual

http://www.arblueclean.com/uploadfiles/image/file/AR118%20Operating%20Manual(1).pdf

Clean room Ovens

Terra Universal: Class 100 Cleanroom Oven Cat# 3700-70 $8,992, 2.8 cu. ft.



http://www.memmert.com/products/cleanroom-drying-oven/cleanroomdryingoven-overview/


http://www.memmert.com/en/products/cleanroom-drying-oven/cleanroomdryingoven-models/models/UFP-500-RR/


http://www.memmert.com/en/products/cleanroom-drying-oven/cleanroomdryingoven-models/models/UFP-500-RR/


http://www.blue-m.com/products/productdetails.aspx?tid=1&pscid=47&plid=85&src=gaw&gclid=CPi77Nukh6sCFYTt7QodQnEgMQ


http://www.tedpella.com/ovens_html/ovens.htm#anchor1388

http://www.carbolite.us/cleanroomovens.html

http://www.despatch.com/industrial-ovens/benchtop-ovens-and-lab-ovens.aspx

Warming tank

A degreaser solution is stored at 60 celsius so foils can be dipped for 1 minute to clean the copper.


check TerraUniversal Ultrasonic Cleaner with heating

2.5 gallon, cat #2619-00 $964.

Need a stainless steel tank to hold the solution and keep it warm

http://www.platingsales.com/electropolish.html

Deionizers

http://www.portablewaterdi.com/deionizers.php

1600 PSI Electric Pressure Washer

http://www.sears.com/shc/s/p_10153_12605_07175265000P?prdNo=4&blockNo=4&blockType=L4

Brookhaven

The basic procedure followed for cleaning GEM foils suggested by Bob Azmoun, a researcher in the PHENIX Group at Brookhaven National Lab. Media:Georgia_3GEM_Detector_UR_Report_F04-1.pdf, Media:UG_Research_Report_David_Fall_04-1.pdf.


The procedure, which is done under a laminar flow hood, is outlined below:

1.Spray down the foils (always at “grazing incidence”) with dry N2

2.Spray down the foils with ethyl-alcohol until foils are completely drenched, using a Windex-type dispenser spray

3.Before the ethanol has a chance to air dry (which could absorb particulate deposits from the air onto the GEM surface), quickly spray down the foils again with dry N2 (again, always at “grazing incidence”)

One should keep in mind that after this process the GEM impedance should drop dramatically, due to the conductivity of the remaining alcohol. However, usually after 5hrs of purging with dry gas, the impedance returns to its original value. "


[1]