The voltages, thresholds and widths are:

PMT voltage, V threshold, mV discr. width, ns
PS1 -1000 -80 20
PS1 -1000 -80 10


Let's do the 2n correlation test with CF252 source. The voltages and thresholds are the same. First the set up is like:

○ PS1 and PS2 are parallel to each other and are faced to the source.
○ the CF252 source in the middle
○ the distance between PS1(PS2) and source is 6 cm

The total number of events (2n fission events + random coincident) are:

total counts time counts/min counts/sec
PS1 255977±505.9 10 min 25597.7±50.6 426.63±0.84
PS1 421917±649.5 10 min 42191.7±64.9 703.19±1.08
PS1+PS2 1224±34.9 10 min 122.4±3.5 2.04±0.06


Second the set up is like:

○ PS1 and PS2 are perpendicular to each other and are faced to the source.
○ the CF252 source in the middle
○ the distance between PS1(PS2) and source is 6 cm

The total number of events (2n fission events + random coincident) are:

total counts time counts/min counts/sec
PS1 250116±500.1 10 min 25011.6±50.0 416.86±0.83
PS1 414774±644.0 10 min 64.4±64.9 691.29±1.07
PS1+PS2 1359±36.9 10 min 135.9±3.7 2.26±0.06