Difference between revisions of "Emittance Measurement with Optical transition Radiation (OTR)"
(7 intermediate revisions by 2 users not shown) | |||
Line 4: | Line 4: | ||
= Set Up = | = Set Up = | ||
+ | |||
+ | OTR target is 1.25’’ in diameter (31.75 mm). OTR target is 10 <math>\mu m</math> thick Aluminium. | ||
== Determining if we are getting OTR == | == Determining if we are getting OTR == | ||
Line 32: | Line 34: | ||
= Beam Based Alignment Procedure = | = Beam Based Alignment Procedure = | ||
− | + | [[HRRL_03-14-2011]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Latest revision as of 16:12, 2 February 2012
Papers
File:M.Castellan NIM A357 1995 pp231.pdf
Set Up
OTR target is 1.25’’ in diameter (31.75 mm). OTR target is 10
thick Aluminium.Determining if we are getting OTR
To determined if what we are seeing is OTR, we need to see a cone. OTR is polarized. If use a polarizer we can determined the cone we are seeing is polarized. Then we can be sure that we got OTR.
The distance from the center of the OTR target (also the center of the 6-way cross) to the closest position we place our first lenses is 13 cm.
Edge to edge OTR cone diameter size (
angle, ) at this distance is 2.665 cm.We need to put lenses or achromat to focus on infinity to see a cone. We had an lens telescope that can focus on infinity with diameter of 2.6 cm. We might be able to push this telescope to a distance closer that 13 mm. We might be able to push telescope to 12 cm distance, then we cone will have diameter of 2,46 cm. Then we can see all the cone. We should do an experiment on this next time.
Beam Line Alignment
From the March 3rd Run, we can see that the beam line is not aligned. We need to align it.
Equipments Needed
1) Laser beam. 2) Lase beam Stand. 3) Mirrors. 4) Crosses.