FC calibration (by view screen monitoring) 3/1/11: Difference between revisions
Jump to navigation
Jump to search
Created page with '[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] 1000 px [https://wiki.iac.isu.edu/index.php/PhotoFiss…' |
No edit summary |
||
| (5 intermediate revisions by the same user not shown) | |||
| Line 2: | Line 2: | ||
[[File:FC Calibration.png | | Below is the FC calibration by using view screen observation for 44 MeV seup | ||
[[File:FC Calibration 3.1.11.png | 1200 px]] | |||
Here are: | |||
#red line is the fitting line for beam up | |||
#green line is the fitting line for beam down | |||
#black line is the fitting line for beam up and down | |||
We can see that all three line is almost the same so we can use the fitting line for whole range of kicker magnet which is | |||
<math>x(cm)= 0.059 + 0.028\cdot I(Ampers)</math> | |||
[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | [https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | ||
Latest revision as of 04:49, 4 March 2011
Below is the FC calibration by using view screen observation for 44 MeV seup
Here are:
- red line is the fitting line for beam up
- green line is the fitting line for beam down
- black line is the fitting line for beam up and down
We can see that all three line is almost the same so we can use the fitting line for whole range of kicker magnet which is
[math]\displaystyle{ x(cm)= 0.059 + 0.028\cdot I(Ampers) }[/math]