− | = | + | = Estimation of Single Bunch Charge = |
+ | |||
+ | |||
S-band linac has RF frequency of 2856 MHz. The period then is: | S-band linac has RF frequency of 2856 MHz. The period then is: | ||
<math>T_{RF}=\frac{1}{f_{RF}}=\frac{1}{2856MHz}=350~ps</math> | <math>T_{RF}=\frac{1}{f_{RF}}=\frac{1}{2856MHz}=350~ps</math> | ||
− | Pulse width of | + | Pulse width of the RF macro-pulse : <math>\Delta t</math>. |
+ | |||
+ | Number of bunches within a pulse: <math>N</math> | ||
+ | |||
+ | <math>N \times T_{RF} = \Delta t</math> | ||
+ | |||
+ | <math>N=\frac{\Delta t}{T_{RF}}</math> | ||
+ | |||
+ | |||
+ | Peak current of the pulse: <math>I_{peak}</math> | ||
+ | |||
+ | Total Charge in a macro pulse: <math>Q_t=I_{peak} \times \Delta t </math> | ||
+ | Charge in a single bunch: <math>Q_{s} = \frac{Q_t}{N} </math> | ||
+ | <math>Q_{s} = \frac{ I_{peak} \times \Delta t }{ \frac{\Delta t}{T_{RF}} } </math> | ||
+ | |||
+ | <math>Q_{s} = { I_{peak} \times }T_{RF} </math> | ||
+ | |||
+ | <math>Q_{s} = { I_{peak} \times }350~ps </math> | ||
+ | |||
+ | |||
+ | {| border="1" cellpadding="5" cellspacing="0" | ||
+ | |- | ||
+ | | I_{peak} (mA) || Q_{s} (pC) | ||
+ | |- | ||
+ | | 10 mA || 3.5 | ||
+ | |- | ||
+ | | 20 mA || 7 | ||
+ | |- | ||
+ | | 30 mA || 10.5 | ||
+ | |- | ||
+ | | 40 mA || 14 | ||
+ | |- | ||
+ | | 50 mA || 17.5 | ||
+ | |- | ||
+ | | 60 mA || 21 | ||
+ | |- | ||
+ | | 70 mA || 24.5 | ||
+ | |- | ||
+ | | 80 mA || 28 | ||
+ | |- | ||
+ | | 90 mA || 31.5 | ||
+ | |- | ||
+ | | 100 mA || 35 | ||
+ | |- | ||
+ | | 110 mA || 38.5 | ||
+ | |- | ||
+ | | 120 mA || 42 | ||
+ | |- | ||
+ | | 130 mA || 45.5 | ||
+ | |- | ||
+ | | 140 mA || 49 | ||
+ | |- | ||
+ | |}<br> | ||
+ | |||
+ | = Average current = | ||
+ | |||
+ | [[File:Scope_image_of_good_Accelarator_setting_by_Dr._Kim_Mar_17_2011.png | 300 px]] | ||
+ | |||
+ | Area under the curve: A = 315.6 nsV. | ||
+ | |||
+ | Macro pulse <math>\Delta t</math> = 200 ns. | ||
+ | |||
+ | Average Voltage: <math>V_{ave} = A / \Delta t</math> = 315.6 nsV / 200 ns. | ||
+ | |||
+ | Scope impedance: R = 50 <math>\Omega </math> | ||
+ | |||
+ | Average Current: <math>I_{ave} = V_{ave}/R = \frac{315.6 nsV } {200 \times 50~\Omega ns} = 31.56~mA</math>. | ||
+ | |||
+ | |||
+ | |||
+ | <math>Q_{s} = { I_{ave} \times }T_{RF} </math> | ||
+ | |||
+ | <math>Q_{s} = { I_{ave} \times }350~ps </math> | ||
+ | |||
+ | |||
+ | <math>Q_{s} = { 31.56~mA \times }350~ps = 11.046~pC</math> | ||
+ | |||
+ | |||
Back to [[Positrons]] | Back to [[Positrons]] |
Latest revision as of 06:28, 21 April 2012
Objectives
1.) Check alignment of the OTR target and beam line with the linac's central axis. If it is misaligned we will work on an alignment plan to be executed after the Wednesday beam test.
2.) Take OTR images, check image focus and light output.
3.) Determine which quad to use for emittance measurements. Establish a quad current scan range.
Steps
Practise Turning HRRL On
Make document of the whole process, write a Standard Operation Process (SOP).
Turn RF off, Try to see Image with filament on
If we can see filament spot on the OTR target, try to focus our image system.
Turn RF On
Turn RF on look at the images, take pictures of the image upload them to the wiki.
Experiment
First Fusing
Image on OTR target
Lights | RF | image |
on | off | |
on (different contrast) | off | |
off | off | |
on | on (27 Hz) |
RF:25-205, Peak Current50mA, Pulse Width_200ns (fwhm)
RF:25, Peak Current60mA, Pulse Width_200ns (fwhm)
RF:50
Light is on
Second Fusing
Focused With Lenses,140 mA 58Hz 100ns
Determine the smallest energy, beam current, pulse width, and rep rate for a visible image.
Visible Image for Lowest Parameters
First Focus
Second Focus
Following images are taken under conditions that: 100 ns FWHM pulse width, 25 Hz Repetition Rate:
20 mA peak current image is the lowest noticeable under 100 ns FWHM pulse width, 25 Hz repetition rate.
Estimation of Single Bunch Charge
S-band linac has RF frequency of 2856 MHz. The period then is:
Pulse width of the RF macro-pulse :
.Number of bunches within a pulse:
Peak current of the pulse:
Total Charge in a macro pulse:
Charge in a single bunch:
I_{peak} (mA) | Q_{s} (pC) |
10 mA | 3.5 |
20 mA | 7 |
30 mA | 10.5 |
40 mA | 14 |
50 mA | 17.5 |
60 mA | 21 |
70 mA | 24.5 |
80 mA | 28 |
90 mA | 31.5 |
100 mA | 35 |
110 mA | 38.5 |
120 mA | 42 |
130 mA | 45.5 |
140 mA | 49 |
Average current
Area under the curve: A = 315.6 nsV.
Macro pulse
= 200 ns.Average Voltage:
= 315.6 nsV / 200 ns.Scope impedance: R = 50
Average Current:
.
Back to Positrons