Difference between revisions of "Ribbon Cable Attenuation Measurements"
Jump to navigation
Jump to search
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | ||
− | =Experimental Set Up= | + | =Attenuation of Ribbon Cable measurements= |
+ | |||
+ | ==Experimental Set Up== | ||
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
Line 9: | Line 11: | ||
|}<br><br> | |}<br><br> | ||
− | =Measurements= | + | ==Measurements== |
{| border="3" cellpadding="20" cellspacing="0" | {| border="3" cellpadding="20" cellspacing="0" | ||
Line 28: | Line 30: | ||
<math>V_2</math> - with Ribbon Cable | <math>V_2</math> - with Ribbon Cable | ||
− | =Pictures about change of pulse shape= | + | ==Pictures about change of pulse shape== |
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
Line 49: | Line 51: | ||
− | =Signal Delay in Ribbon Cable= | + | =Signal Delay in Ribbon Cable measurements= |
− | ==Experimental | + | ==Experimental Set Up== |
+ | |||
+ | {| border="1" cellpadding="20" cellspacing="0" | ||
+ | | setup without Ribbon Cable|| setup with Ribbon Cable | ||
+ | |- | ||
+ | | [[File:Setup_2signal_before.JPG | 400 px]] || [[File:Setup_2signal_after.JPG | 400 px]] | ||
+ | |}<br><br> | ||
==Measurements== | ==Measurements== |
Latest revision as of 22:27, 19 January 2011
Attenuation of Ribbon Cable measurements
Experimental Set Up
setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
Pulse width | Attenuation, % | Comments | ||
10 % | ||||
16 % | ||||
40 % | see pictures about change of pulse shape | |||
44 % | see pictures about change of pulse shape | |||
55 % | see pictures about change of pulse shape |
- without Ribbon Cable - with Ribbon Cable
Pictures about change of pulse shape
pulse without Ribbon Cable | pulse with Ribbon Cable |
pulse without Ribbon Cable | pulse with Ribbon Cable |
pulse without Ribbon Cable | pulse with Ribbon Cable |
Signal Delay in Ribbon Cable measurements
Experimental Set Up
setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
2 pulses without Ribbon Cable | 2 pulses with Ribbon Cable |
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. For other pulse width the delay is about the same.