+ | =Attenuation of Ribbon Cable measurements= | ||
==Experimental Set Up== | ==Experimental Set Up== | ||
Line 49: | Line 51: | ||
− | + | =Signal Delay in Ribbon Cable measurements= | |
+ | |||
+ | ==Experimental Set Up== | ||
+ | |||
+ | {| border="1" cellpadding="20" cellspacing="0" | ||
+ | | setup without Ribbon Cable|| setup with Ribbon Cable | ||
+ | |- | ||
+ | | [[File:Setup_2signal_before.JPG | 400 px]] || [[File:Setup_2signal_after.JPG | 400 px]] | ||
+ | |}<br><br> | ||
+ | |||
+ | ==Measurements== | ||
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
Line 57: | Line 69: | ||
|}<br><br> | |}<br><br> | ||
− | We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse | + | We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. |
For other pulse width the delay is about the same. | For other pulse width the delay is about the same. | ||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | [http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] |
Latest revision as of 22:27, 19 January 2011
Attenuation of Ribbon Cable measurements
Experimental Set Up
setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
Pulse width | Attenuation, % | Comments | ||
10 % | ||||
16 % | ||||
40 % | see pictures about change of pulse shape | |||
44 % | see pictures about change of pulse shape | |||
55 % | see pictures about change of pulse shape |
- without Ribbon Cable - with Ribbon Cable
Pictures about change of pulse shape
pulse without Ribbon Cable | pulse with Ribbon Cable |
pulse without Ribbon Cable | pulse with Ribbon Cable |
pulse without Ribbon Cable | pulse with Ribbon Cable |
Signal Delay in Ribbon Cable measurements
Experimental Set Up
setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
2 pulses without Ribbon Cable | 2 pulses with Ribbon Cable |
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. For other pulse width the delay is about the same.