Ribbon Cable Attenuation Measurements: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
| (32 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | |||
=Attenuation of Ribbon Cable measurements= | |||
==Experimental Set Up== | ==Experimental Set Up== | ||
{| border="1" cellpadding="20" cellspacing="0" | |||
| setup without Ribbon Cable|| setup with Ribbon Cable | |||
|- | |||
| [[File:Setup before.JPG | 400 px]] || [[File:Setup after.JPG | 400 px]] | |||
|}<br><br> | |||
==Measurements== | ==Measurements== | ||
{| border="3" cellpadding="20" cellspacing="0" | {| border="3" cellpadding="20" cellspacing="0" | ||
|Pulse width ||<math>V_1</math> ||<math>V_2</math> ||Attenuation, % ||Comments | |Pulse width ||<math>V_1</math>||<math>V_2</math>||Attenuation, % ||Comments | ||
|- | |- | ||
|<math>100\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.5\ V</math> ||10 % || | |<math>100\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.5\ V</math> ||10 % || | ||
| Line 11: | Line 20: | ||
|<math>10\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.2\ V</math> ||16 % || | |<math>10\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.2\ V</math> ||16 % || | ||
|- | |- | ||
|<math>1\ \mu s</math> ||<math>5.0\ V</math> ||<math>3.0\ V</math> ||40 % ||see pictures about pulse | |<math>1\ \mu s</math> ||<math>5.0\ V</math> ||<math>3.0\ V</math> ||40 % ||see pictures about change of pulse shape | ||
|- | |- | ||
|<math>100\ ns</math> ||<math>5.0\ V</math> ||<math>2.8\ V</math> ||44 % ||see pictures about pulse | |<math>100\ ns</math> ||<math>5.0\ V</math> ||<math>2.8\ V</math> ||44 % ||see pictures about change of pulse shape | ||
|- | |||
|<math>30\ ns</math> ||<math>4.0\ V</math> ||<math>1.8\ V</math> ||55 % ||see pictures about change of pulse shape | |||
|} | |||
<math>V_1</math> - without Ribbon Cable | |||
<math>V_2</math> - with Ribbon Cable | |||
==Pictures about change of pulse shape== | |||
{| border="1" cellpadding="20" cellspacing="0" | |||
| <math>1\ \mu s</math> pulse without Ribbon Cable|| <math>1\ \mu s</math> pulse with Ribbon Cable | |||
|- | |- | ||
|< | | [[File:1us before.JPG | 400 px]] || [[File:1us after.JPG | 400 px]] | ||
|}<br><br> | |||
{| border="1" cellpadding="20" cellspacing="0" | |||
| <math>100\ ns</math> pulse without Ribbon Cable|| <math>100\ ns</math> pulse with Ribbon Cable | |||
|- | |- | ||
| [[File:100ns before.JPG | 400 px]] || [[File:100ns after.JPG | 400 px]] | |||
|}<br><br> | |||
{| border="1" cellpadding="20" cellspacing="0" | |||
| <math>30\ ns</math> pulse without Ribbon Cable|| <math>30\ ns</math> pulse with Ribbon Cable | |||
|- | |||
| [[File:30ns before.JPG | 400 px]] || [[File:30ns after.JPG | 400 px]] | |||
|}<br><br> | |||
=Signal Delay in Ribbon Cable measurements= | |||
==Experimental Set Up== | |||
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
| || | | setup without Ribbon Cable|| setup with Ribbon Cable | ||
|- | |- | ||
| [[File:Setup_2signal_before.JPG | 400 px]] || [[File:Setup_2signal_after.JPG | 400 px]] | |||
|}<br><br> | |||
==Measurements== | |||
{| border="1" cellpadding="20" cellspacing="0" | |||
| 2 pulses without Ribbon Cable|| 2 pulses with Ribbon Cable | |||
|- | |||
| [[File:100ns delay before.JPG | 400 px]] || [[File:100ns delay after.JPG | 400 px]] | |||
|}<br><br> | |||
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. | |||
For other pulse width the delay is about the same. | |||
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | |||
Latest revision as of 22:27, 19 January 2011
Attenuation of Ribbon Cable measurements
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
| Pulse width | [math]\displaystyle{ V_1 }[/math] | [math]\displaystyle{ V_2 }[/math] | Attenuation, % | Comments |
| [math]\displaystyle{ 100\ \mu s }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 4.5\ V }[/math] | 10 % | |
| [math]\displaystyle{ 10\ \mu s }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 4.2\ V }[/math] | 16 % | |
| [math]\displaystyle{ 1\ \mu s }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 3.0\ V }[/math] | 40 % | see pictures about change of pulse shape |
| [math]\displaystyle{ 100\ ns }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 2.8\ V }[/math] | 44 % | see pictures about change of pulse shape |
| [math]\displaystyle{ 30\ ns }[/math] | [math]\displaystyle{ 4.0\ V }[/math] | [math]\displaystyle{ 1.8\ V }[/math] | 55 % | see pictures about change of pulse shape |
[math]\displaystyle{ V_1 }[/math] - without Ribbon Cable [math]\displaystyle{ V_2 }[/math] - with Ribbon Cable
Pictures about change of pulse shape
| [math]\displaystyle{ 1\ \mu s }[/math] pulse without Ribbon Cable | [math]\displaystyle{ 1\ \mu s }[/math] pulse with Ribbon Cable |
| [math]\displaystyle{ 100\ ns }[/math] pulse without Ribbon Cable | [math]\displaystyle{ 100\ ns }[/math] pulse with Ribbon Cable |
| [math]\displaystyle{ 30\ ns }[/math] pulse without Ribbon Cable | [math]\displaystyle{ 30\ ns }[/math] pulse with Ribbon Cable |
Signal Delay in Ribbon Cable measurements
Experimental Set Up
| setup without Ribbon Cable | setup with Ribbon Cable |
Measurements
| 2 pulses without Ribbon Cable | 2 pulses with Ribbon Cable |
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. For other pulse width the delay is about the same.