Ribbon Cable Attenuation Measurements: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Shaproma (talk | contribs)
Shaproma (talk | contribs)
No edit summary
 
(32 intermediate revisions by the same user not shown)
Line 1: Line 1:
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]
=Attenuation of Ribbon Cable measurements=
==Experimental Set Up==
==Experimental Set Up==


{| border="1"  cellpadding="20" cellspacing="0"
| setup without Ribbon Cable|| setup with Ribbon Cable
|-
| [[File:Setup before.JPG | 400 px]] || [[File:Setup after.JPG | 400 px]]
|}<br><br>


==Measurements==
==Measurements==


{| border="3"  cellpadding="20" cellspacing="0"
{| border="3"  cellpadding="20" cellspacing="0"
|Pulse width ||<math>V_1</math> ||<math>V_2</math> ||Attenuation, % ||Comments
|Pulse width ||<math>V_1</math>||<math>V_2</math>||Attenuation, % ||Comments
|-
|-
|<math>100\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.5\ V</math> ||10 % ||
|<math>100\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.5\ V</math> ||10 % ||
Line 11: Line 20:
|<math>10\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.2\ V</math> ||16 % ||
|<math>10\ \mu s</math> ||<math>5.0\ V</math> ||<math>4.2\ V</math> ||16 % ||
|-
|-
|<math>1\ \mu s</math> ||<math>5.0\ V</math> ||<math>3.0\ V</math> ||40 % ||see pictures about pulse's shape change
|<math>1\ \mu s</math> ||<math>5.0\ V</math> ||<math>3.0\ V</math> ||40 % ||see pictures about change of pulse shape
|-
|-
|<math>100\ ns</math> ||<math>5.0\ V</math> ||<math>2.8\ V</math> ||44 % ||see pictures about pulse's shape change
|<math>100\ ns</math> ||<math>5.0\ V</math> ||<math>2.8\ V</math> ||44 % ||see pictures about change of pulse shape
|-
|<math>30\ ns</math> ||<math>4.0\ V</math> ||<math>1.8\ V</math> ||55 % ||see pictures about change of pulse shape
|}
 
<math>V_1</math> - without Ribbon Cable
<math>V_2</math> - with Ribbon Cable
 
==Pictures about change of pulse shape==
 
{| border="1"  cellpadding="20" cellspacing="0"
| <math>1\ \mu s</math> pulse without Ribbon Cable|| <math>1\ \mu s</math> pulse with Ribbon Cable
|-
|-
|<math>30\ ns</math> ||<math>4.0\ V</math> ||<math>1.8\ V</math> ||55 % ||see pictures about pulse's shape change
| [[File:1us before.JPG | 400 px]] || [[File:1us after.JPG | 400 px]]
|}<br><br>
 
{| border="1"  cellpadding="20" cellspacing="0"
| <math>100\ ns</math> pulse without Ribbon Cable|| <math>100\ ns</math> pulse with Ribbon Cable
|-
|-
| [[File:100ns before.JPG | 400 px]] || [[File:100ns after.JPG | 400 px]]
|}<br><br>


{| border="1"  cellpadding="20" cellspacing="0"
| <math>30\ ns</math> pulse without Ribbon Cable|| <math>30\ ns</math> pulse with Ribbon Cable
|-
| [[File:30ns before.JPG | 400 px]] || [[File:30ns after.JPG | 400 px]]
|}<br><br>


<math>1\ \mu s</math> pulse width
 
=Signal Delay in Ribbon Cable measurements=
 
==Experimental Set Up==


{| border="1"  cellpadding="20" cellspacing="0"
{| border="1"  cellpadding="20" cellspacing="0"
| ||  
| setup without Ribbon Cable|| setup with Ribbon Cable
|-
|-
| [[File:Setup_2signal_before.JPG | 400 px]] || [[File:Setup_2signal_after.JPG | 400 px]]
|}<br><br>
==Measurements==
{| border="1"  cellpadding="20" cellspacing="0"
| 2 pulses without Ribbon Cable|| 2 pulses with Ribbon Cable
|-
| [[File:100ns delay before.JPG | 400 px]] || [[File:100ns delay after.JPG | 400 px]]
|}<br><br>
We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse.
For other pulse width the delay is about the same.
[http://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]

Latest revision as of 22:27, 19 January 2011

Go Back

Attenuation of Ribbon Cable measurements

Experimental Set Up

setup without Ribbon Cable setup with Ribbon Cable



Measurements

Pulse width [math]\displaystyle{ V_1 }[/math] [math]\displaystyle{ V_2 }[/math] Attenuation, % Comments
[math]\displaystyle{ 100\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 4.5\ V }[/math] 10 %
[math]\displaystyle{ 10\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 4.2\ V }[/math] 16 %
[math]\displaystyle{ 1\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 3.0\ V }[/math] 40 % see pictures about change of pulse shape
[math]\displaystyle{ 100\ ns }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 2.8\ V }[/math] 44 % see pictures about change of pulse shape
[math]\displaystyle{ 30\ ns }[/math] [math]\displaystyle{ 4.0\ V }[/math] [math]\displaystyle{ 1.8\ V }[/math] 55 % see pictures about change of pulse shape
[math]\displaystyle{ V_1 }[/math] - without Ribbon Cable
[math]\displaystyle{ V_2 }[/math] - with Ribbon Cable

Pictures about change of pulse shape

[math]\displaystyle{ 1\ \mu s }[/math] pulse without Ribbon Cable [math]\displaystyle{ 1\ \mu s }[/math] pulse with Ribbon Cable



[math]\displaystyle{ 100\ ns }[/math] pulse without Ribbon Cable [math]\displaystyle{ 100\ ns }[/math] pulse with Ribbon Cable



[math]\displaystyle{ 30\ ns }[/math] pulse without Ribbon Cable [math]\displaystyle{ 30\ ns }[/math] pulse with Ribbon Cable




Signal Delay in Ribbon Cable measurements

Experimental Set Up

setup without Ribbon Cable setup with Ribbon Cable



Measurements

2 pulses without Ribbon Cable 2 pulses with Ribbon Cable



We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. 
For other pulse width the delay is about the same.


Go Back