Difference between revisions of "HRRL"

From New IAC Wiki
Jump to navigation Jump to search
 
(43 intermediate revisions by 2 users not shown)
Line 9: Line 9:
 
|Min Energy
 
|Min Energy
 
|Max Energy
 
|Max Energy
 +
|Max Power [E(MeV) * I_peak(\mu A) *Pulse Width * Rep rate]
 
|-
 
|-
| 80 mA  || || 25 ns ||100 ns || 1 kHz|| 10 MeV ||16 MeV
+
| 80 mA  ||8 mA || 25 ns || 1 kHz|| 3 MeV ||16 MeV || 16 MeV * 80,000 <math>\mu</math> A*(.1 <math>\mu</math> s)(1 kHz)= 128 W
 
|}<br>
 
|}<br>
  
 +
HRRL is limited to 100 ns pulse width due to limited shielding.
 +
 +
 +
[[HRRL room dimensions]]
  
  
[[5-19-08]]
 
  
 
[[HRRL_Simulations]]
 
[[HRRL_Simulations]]
 +
 +
[[PhotoFission with Polarized Photons from HRRL]]
 +
 +
[[Neutron_Corr]]
  
 
[[Radiators Temperature]]
 
[[Radiators Temperature]]
Line 24: Line 32:
 
[[http://www.fzd.de/db/Cms?pOid=10568&pNid=0]]
 
[[http://www.fzd.de/db/Cms?pOid=10568&pNid=0]]
  
[[HRRL room dimensions]]
+
[[Detector Tests Using HRRL]]
 +
 
 +
[[HRRLrun_3-22-26-2010]]
 +
 
  
[[Radiator foil link]]
+
[[HRRL_OSA_Docs]]
[[http://www.lebowcompany.com/foils_list.htm#TITANIUM]]
 
  
[[Eγ]]
+
[http://wiki.iac.isu.edu/index.php/Laboratory_for_Detector_Science go back]
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/Egamma]]
 
  
[[Using Carbon or Aluminum to block photons]]
 
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/CarbonOrAluminum]]
 
  
[[Eγ vs probability with 5 cm of D20 ]]
+
2758 , NaI2 @ 1059Volts  Co-60 source
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/EgammaVsD20Probability5cm]]
 
  
[[Eγ vs probability with 8 cm of D20 ]]
+
2759 , NaI2@ 1059Volts  Cf-252 source
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/EgammaVsD20Probability8cm]]
 
  
[[Thickness of Lead to block photons]]
+
2760 , NaI2@ 1009Volts  Co-60 source
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/ThicknessOfLeadToBlockPhotons]]
 
  
[[Where does the radiator need to be?]]
+
2761 , NaI2@ 1009Volts  Cf-252 source
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/RadiatorLocation]]
 
  
[[Determining the uncertainty of Eγ]]
+
2762 , NaI2@ 960Volts  Cf-252 source
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/Uncertainty]]
 
  
[[Things That Still Need to Get Done]]
+
2763 , NaI2@ 960Volts  Co-60 source
[[http://www.iac.isu.edu/mediawiki/index.php/HRRL/NeedToGetDone]]
 
  
[[Notes from July 2nd, 2008 Meeting]]
+
2764 , NaI2@ 960Volts  Cf-252 source, 2" Pb half brick
[[http://www.iac.isu.edu/mediawiki/index.php/Notes07022008]]
 
  
[[Brems Intensity Spectrum (with Collimation Factors) Plots]]
 
[[http://www.iac.isu.edu/mediawiki/index.php/BISwCF]]
 
  
[[Brems Intensity Spectrum (without Collimation Factors) Plots]]
+
2765 , NaI2@ 960Volts  Cf-252 source, 2" Pb out 2" green borated brick in
[[http://www.iac.isu.edu/mediawiki/index.php/BISwnCF]]
 

Latest revision as of 20:13, 10 August 2012

Electron Accelerator Specifications:

[math]I_{Max peak}[/math] [math]I_{Min peak}[/math] Min Pulse Width Max Rep Rate Min Energy Max Energy Max Power [E(MeV) * I_peak(\mu A) *Pulse Width * Rep rate]
80 mA 8 mA 25 ns 1 kHz 3 MeV 16 MeV 16 MeV * 80,000 [math]\mu[/math] A*(.1 [math]\mu[/math] s)(1 kHz)= 128 W


HRRL is limited to 100 ns pulse width due to limited shielding.


HRRL room dimensions


HRRL_Simulations

PhotoFission with Polarized Photons from HRRL

Neutron_Corr

Radiators Temperature

Multiple scattering Angle [[1]]

Detector Tests Using HRRL

HRRLrun_3-22-26-2010


HRRL_OSA_Docs

go back


2758 , NaI2 @ 1059Volts Co-60 source

2759 , NaI2@ 1059Volts Cf-252 source

2760 , NaI2@ 1009Volts Co-60 source

2761 , NaI2@ 1009Volts Cf-252 source

2762 , NaI2@ 960Volts Cf-252 source

2763 , NaI2@ 960Volts Co-60 source

2764 , NaI2@ 960Volts Cf-252 source, 2" Pb half brick


2765 , NaI2@ 960Volts Cf-252 source, 2" Pb out 2" green borated brick in