Difference between revisions of "Run Plan"
(4 intermediate revisions by the same user not shown) | |||
Line 5: | Line 5: | ||
Set coincidence gate of two paddles to fall within 15-20 ns | Set coincidence gate of two paddles to fall within 15-20 ns | ||
− | Verify that | + | Verify that scalers are set for the paddles: singles from front and back + coincidence. |
Verify that gas is flowing into Accelerator Room (bubbles). | Verify that gas is flowing into Accelerator Room (bubbles). | ||
− | The zero point is where the laser beam intersects the feedthrough trumpet. | + | The zero point is where the laser beam intersects the feedthrough trumpet in the plane of sense |
− | 50 Hz, we can get ample statististics for a 2-min run at each setting. This is to be | + | wire 4. The laser beam will first strike the guard wire trumpet. At 30 to 50 Hz, we can get ample statististics for a 2-min run at each setting. This is to be confirmed by the scalers. |
− | confirmed by the | ||
''x'': along wire and ''y'': vertical distance from sense wire 4. | ''x'': along wire and ''y'': vertical distance from sense wire 4. | ||
Line 26: | Line 25: | ||
o Set: | o Set: | ||
sense: +1375 to +1550V in steps of 25V | sense: +1375 to +1550V in steps of 25V | ||
− | field -688 to - | + | field -688 to -775V in steps of 12.5V (12 or 13V) |
− | guard +688 to + | + | guard +688 to +775V in steps of 12.5V |
o Once we find the "sweet spot" fix settings of field, guard, and | o Once we find the "sweet spot" fix settings of field, guard, and | ||
Line 39: | Line 38: | ||
− | '''Run -- BRICK IN''' | + | '''Run -- BRICK IN''' (Thick as a brick) |
o With the canonical settings. Positions (reckoned in mm) ''x'': 50, 25, 0 ; ''y'': 2, 0, -2, | o With the canonical settings. Positions (reckoned in mm) ''x'': 50, 25, 0 ; ''y'': 2, 0, -2, | ||
Line 47: | Line 46: | ||
o Repeat measurements for efficiency and charge/evt. | o Repeat measurements for efficiency and charge/evt. | ||
+ | |||
+ | ''Increase current into cell to see if we can see the second ionization peak in the first paddle.'' |
Latest revision as of 20:06, 5 January 2008
Run Plan.
Setup.
Set coincidence gate of two paddles to fall within 15-20 ns
Verify that scalers are set for the paddles: singles from front and back + coincidence.
Verify that gas is flowing into Accelerator Room (bubbles).
The zero point is where the laser beam intersects the feedthrough trumpet in the plane of sense wire 4. The laser beam will first strike the guard wire trumpet. At 30 to 50 Hz, we can get ample statististics for a 2-min run at each setting. This is to be confirmed by the scalers.
x: along wire and y: vertical distance from sense wire 4.
Run -- BRICK OUT
Plateauing
o Move chamber horizontally to 5cm.
o Move chamber up 2mm
o Set: sense: +1375 to +1550V in steps of 25V field -688 to -775V in steps of 12.5V (12 or 13V) guard +688 to +775V in steps of 12.5V o Once we find the "sweet spot" fix settings of field, guard, and sense wires. Move chamber to +3mm, 2mm, 1mm, 0, -1mm, -2mm, -3mm.
Efficiency tests + charge/evt (canonical settings)
o Positions (reckoned in mm) x: 25, 20, 15, 10, 5, 0 ; y: 3, 2, 1, 0, -1, -2, -3.
Run -- BRICK IN (Thick as a brick)
o With the canonical settings. Positions (reckoned in mm) x: 50, 25, 0 ; y: 2, 0, -2,
SWAP METALICA and PLASTICA.
o Repeat measurements for efficiency and charge/evt.
Increase current into cell to see if we can see the second ionization peak in the first paddle.