PbF2 CrystalNumber33: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
Oborn (talk | contribs)
 
(One intermediate revision by the same user not shown)
Line 67: Line 67:


=12/5/07=
=12/5/07=
Under blue light for ~22 hours.


;Transparency measurement
;Transparency measurement
Line 106: Line 109:
@16:25 [[Image:Block33 4.25pm.JPG | 200 px]]
@16:25 [[Image:Block33 4.25pm.JPG | 200 px]]


@16:35 [[Image:Block33 4.25pm.JPG | 200 px]]
@16:35 [[Image:Block33 4.35pm.JPG | 200 px]]
 
@16:45 [[Image:Block33 4.45pm.JPG | 200 px]]
 
@16:55 [[Image:Block33 4.55pm.JPG | 200 px]]
 





Latest revision as of 23:59, 5 December 2007

Below are the resulting transparency measurements for PbF2 block # 33

12/4/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 13:09
beam stop: 17:09
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns

@ 13:50

@ 14:02

@ 14:12

@ 14:22

@ 14:32

@ 14:42

@ 14:52

@ 15:02

@ 15:27

@ 15:41

@ 15:53

@ 16:11

@ 16:27

@ 16:37

@ 16:47

@ 16:57

@ 17:07

Dose rate measurements (@1709 hours)
[math]\displaystyle{ \gamma }[/math]-radiation 500 uR/hr
[math]\displaystyle{ \beta }[/math]-radiation: 500 uR/hr


Transparency measurements (@1716 hours)

12/5/07

Under blue light for ~22 hours.


Transparency measurement
Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 15:00
beam stop:
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns


@15:05

@15:25

@15:35

@15:45

@15:55

@16:05

@16:15

@16:25

@16:35

@16:45

@16:55








Go Back