Difference between revisions of "CH He3 Attenuation Measurements: 3 Different Cf252 Sources"
Jump to navigation
Jump to search
(17 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | ='''Results'''= | ||
+ | |||
+ | <gallery heights="300" widths="350" class="center"> | ||
+ | CH_High_And_Unknown_Activity_Source.png|<span style="color:#FF0000">'''Red:'''</span> Log plot of scalar measurements using the high activity source with <small><math>Ae^Bx+C</math></small> fit. <span style="color:#0000ff">'''Blue:'''</span> Log plot of scalar measurements using the undetermined activity source with <small><math>Ae^Bx+C</math></small> | ||
+ | |||
+ | CH NoPolyScaled Borated Poly Atten He3 500uCi ADC 05192022.png|Energy spectrum of He3 tube using peak sensing ADC for the varying thicknesses of borated polyethylene. Note that the 0" of poly (open source) is scaled by <small><math>\frac{1}{3}</math></small>. | ||
+ | |||
+ | PS_Sim_He3_Energy_Spectrum_Cf252_05112022.png|Simulated energy spectrum of He3 tube in borated poly box. | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | </gallery> | ||
+ | |||
='''Attenuation Experiment using New Modules in Electronics Chain and Inside Borated Poly Box'''= | ='''Attenuation Experiment using New Modules in Electronics Chain and Inside Borated Poly Box'''= | ||
Line 40: | Line 54: | ||
* Pulse width as measured on scope: ~43ns | * Pulse width as measured on scope: ~43ns | ||
− | |||
− | |||
=='''Background Measurements'''== | =='''Background Measurements'''== | ||
Line 49: | Line 61: | ||
| '''1250V Background Measurements'''|| | | '''1250V Background Measurements'''|| | ||
|- | |- | ||
− | | Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Source || Counts || Run Time (Sec) | + | | Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Source || Counts || Run Time (Sec) |
|- | |- | ||
− | | 1 || Detector on 3D printed stands at +1250V || 255 || No || | + | | 1 || Detector on 3D printed stands at +1250V || 255 || No || 33 || 100 |
|- | |- | ||
− | | 2 || Detector on 3D printed stands at +1250V || 255 || No || | + | | 2 || Detector on 3D printed stands at +1250V || 255 || No || 24 || 100 |
|- | |- | ||
− | | 3 || Detector on 3D printed stands at +1250V || 255 || No || | + | | 3 || Detector on 3D printed stands at +1250V || 255 || No || 30 || 100 |
|- | |- | ||
− | | 4 || Detector on 3D printed stands at +1250V || 255 || No || | + | | 4 || Detector on 3D printed stands at +1250V || 255 || No || 26 || 100 |
|- | |- | ||
− | | 5 || Detector on 3D printed stands at +1250V || 255 || No || | + | | 5 || Detector on 3D printed stands at +1250V || 255 || No || 19 || 100 |
|- | |- | ||
|} | |} | ||
Line 266: | Line 278: | ||
|- | |- | ||
| 5 || Detector on poly at +1250V || 80 || Yes || 394 || 100 | | 5 || Detector on poly at +1250V || 80 || Yes || 394 || 100 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ==='''Lead Attenuation Measurements'''=== | ||
+ | |||
+ | The purpose of these measurements was to determine if photon build up in the He3 tube was a significant effect to consider when trying to determine the activity of the Unknown Source | ||
+ | |||
+ | 4/5/22 | ||
+ | |||
+ | ===='''Lead Open Source'''==== | ||
+ | |||
+ | {| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | ||
+ | |- | ||
+ | | '''1250V source in'''|| | ||
+ | |- | ||
+ | | Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Source || Counts || Run Time (Sec) | ||
+ | |- | ||
+ | | 1 || Detector on poly at +1250V || 80 || Yes || 3873 || 100 | ||
+ | |- | ||
+ | | 2 || Detector on poly at +1250V || 80 || Yes || 3909 || 100 | ||
+ | |- | ||
+ | | 3 || Detector on poly at +1250V || 80 || Yes || 3859 || 100 | ||
+ | |- | ||
+ | | 4 || Detector on poly at +1250V || 80 || Yes || 3944 || 100 | ||
+ | |- | ||
+ | | 5 || Detector on poly at +1250V || 80 || Yes || 3812 || 100 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ===='''1" Lead'''==== | ||
+ | |||
+ | {| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | ||
+ | |- | ||
+ | | '''1250V source in'''|| | ||
+ | |- | ||
+ | | Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Source || Counts || Run Time (Sec) | ||
+ | |- | ||
+ | | 1 || Detector on poly at +1250V || 80 || Yes || 4152 || 100 | ||
+ | |- | ||
+ | | 2 || Detector on poly at +1250V || 80 || Yes || 3945 || 100 | ||
+ | |- | ||
+ | | 3 || Detector on poly at +1250V || 80 || Yes || 4141 || 100 | ||
+ | |- | ||
+ | | 4 || Detector on poly at +1250V || 80 || Yes || 3974 || 100 | ||
+ | |- | ||
+ | | 5 || Detector on poly at +1250V || 80 || Yes || 4154 || 100 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ===='''2" Lead'''==== | ||
+ | |||
+ | {| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | ||
+ | |- | ||
+ | | '''1250V source in'''|| | ||
+ | |- | ||
+ | | Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Source || Counts || Run Time (Sec) | ||
+ | |- | ||
+ | | 1 || Detector on poly at +1250V || 80 || Yes || 3509 || 100 | ||
+ | |- | ||
+ | | 2 || Detector on poly at +1250V || 80 || Yes || 3472 || 100 | ||
+ | |- | ||
+ | | 3 || Detector on poly at +1250V || 80 || Yes || 3387 || 100 | ||
+ | |- | ||
+ | | 4 || Detector on poly at +1250V || 80 || Yes || 3488 || 100 | ||
+ | |- | ||
+ | | 5 || Detector on poly at +1250V || 80 || Yes || 3463 || 100 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ===='''3" Lead'''==== | ||
+ | |||
+ | {| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | ||
+ | |- | ||
+ | | '''1250V source in'''|| | ||
+ | |- | ||
+ | | Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Source || Counts || Run Time (Sec) | ||
+ | |- | ||
+ | | 1 || Detector on poly at +1250V || 80 || Yes || 2995 || 100 | ||
+ | |- | ||
+ | | 2 || Detector on poly at +1250V || 80 || Yes || 2921 || 100 | ||
+ | |- | ||
+ | | 3 || Detector on poly at +1250V || 80 || Yes || 2956 || 100 | ||
+ | |- | ||
+ | | 4 || Detector on poly at +1250V || 80 || Yes || 2916 || 100 | ||
+ | |- | ||
+ | | 5 || Detector on poly at +1250V || 80 || Yes || 3015 || 100 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ===='''4" Lead'''==== | ||
+ | |||
+ | {| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | ||
+ | |- | ||
+ | | '''1250V source in'''|| | ||
+ | |- | ||
+ | | Run Number || Configuration || Discriminator Threshold (mV) || Cf-252 Source || Counts || Run Time (Sec) | ||
+ | |- | ||
+ | | 1 || Detector on poly at +1250V || 80 || Yes || 2630 || 100 | ||
+ | |- | ||
+ | | 2 || Detector on poly at +1250V || 80 || Yes || 2601 || 100 | ||
+ | |- | ||
+ | | 3 || Detector on poly at +1250V || 80 || Yes || 2558 || 100 | ||
+ | |- | ||
+ | | 4 || Detector on poly at +1250V || 80 || Yes || 2629 || 100 | ||
+ | |- | ||
+ | | 5 || Detector on poly at +1250V || 80 || Yes || 2650 || 100 | ||
|- | |- | ||
|} | |} | ||
Line 371: | Line 489: | ||
|- | |- | ||
|} | |} | ||
− | |||
− | |||
='''Previous Page'''= | ='''Previous Page'''= | ||
[[CaGaS Phase II]] | [[CaGaS Phase II]] |
Latest revision as of 18:21, 17 June 2022
Results
Attenuation Experiment using New Modules in Electronics Chain and Inside Borated Poly Box
Electronics Chain (Poly Box)
Include schematic of electronics chain
Components
Each component of electronics chain with make/model, function, and brief description of why it's present
Ortec 142PC Pre-amp
Pre-amp for the He3 tube
CAEN Quad Linear Fan In - Fan Out Model N25 Tag #15687
- The fan in/out is used to duplicate the pulse to run the spec amp and watch the signal on the scope for any anomalies.
- The fan in/out is also used to invert the signal from the spec amp to send a negative pulse to the discriminator to trigger the scalar.
Ortec Spec Amp Model 672
- 10x Course Gain
- 1x Fine Gain
- 0.5us Shaping Time
- Uni Shaping: Gaussian
- Input: Norm (+)
- Output: Unipolar
- Manual Pole Zero adjustment
LeCroy Discriminator Model 821 Serial #B16303
- Variable threshold
- Pulse width as measured on scope: ~43ns
Background Measurements
1250V Background Measurements | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on 3D printed stands at +1250V | 255 | No | 33 | 100 |
2 | Detector on 3D printed stands at +1250V | 255 | No | 24 | 100 |
3 | Detector on 3D printed stands at +1250V | 255 | No | 30 | 100 |
4 | Detector on 3D printed stands at +1250V | 255 | No | 26 | 100 |
5 | Detector on 3D printed stands at +1250V | 255 | No | 19 | 100 |
High Activity Source Poly Box Attenuation Measurements
472
Ci at time of measurement.Open Source
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 34456 | 10 |
2 | Detector on poly at +1250V | 80 | Yes | 34920 | 10 |
3 | Detector on poly at +1250V | 80 | Yes | 34422 | 10 |
4 | Detector on poly at +1250V | 80 | Yes | 34007 | 10 |
5 | Detector on poly at +1250V | 80 | Yes | 34420 | 10 |
2" Green poly (one brick) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 7538 | 10 |
2 | Detector on poly at +1250V | 80 | Yes | 7515 | 10 |
3 | Detector on poly at +1250V | 80 | Yes | 7613 | 10 |
4 | Detector on poly at +1250V | 80 | Yes | 7566 | 10 |
5 | Detector on poly at +1250V | 80 | Yes | 7510 | 10 |
4" Green poly (two bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 4758 | 10 |
2 | Detector on poly at +1250V | 80 | Yes | 4798 | 10 |
3 | Detector on poly at +1250V | 80 | Yes | 4722 | 10 |
4 | Detector on poly at +1250V | 80 | Yes | 4859 | 10 |
5 | Detector on poly at +1250V | 80 | Yes | 4672 | 10 |
6" Green poly (three bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 3664 | 10 |
2 | Detector on poly at +1250V | 80 | Yes | 3627 | 10 |
3 | Detector on poly at +1250V | 80 | Yes | 3699 | 10 |
4 | Detector on poly at +1250V | 80 | Yes | 3688 | 10 |
5 | Detector on poly at +1250V | 80 | Yes | 3500 | 10 |
8" Green poly (four bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 3140 | 10 |
2 | Detector on poly at +1250V | 80 | Yes | 3064 | 10 |
3 | Detector on poly at +1250V | 80 | Yes | 3030 | 10 |
4 | Detector on poly at +1250V | 80 | Yes | 3095 | 10 |
5 | Detector on poly at +1250V | 80 | Yes | 3113 | 10 |
Undetermined Activity Source Poly Box Attenuation Measurements
Open Source
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 3873 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 3909 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 3859 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 3944 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 3812 | 100 |
2" Green poly (one brick) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 764 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 819 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 818 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 815 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 913 | 100 |
4" Green poly (two bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 486 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 509 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 531 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 544 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 530 | 100 |
6" Green poly (three bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 415 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 373 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 380 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 397 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 419 | 100 |
8" Green poly (four bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 371 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 396 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 351 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 366 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 394 | 100 |
Lead Attenuation Measurements
The purpose of these measurements was to determine if photon build up in the He3 tube was a significant effect to consider when trying to determine the activity of the Unknown Source
4/5/22
Lead Open Source
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 3873 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 3909 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 3859 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 3944 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 3812 | 100 |
1" Lead
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 4152 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 3945 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 4141 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 3974 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 4154 | 100 |
2" Lead
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 3509 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 3472 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 3387 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 3488 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 3463 | 100 |
3" Lead
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 2995 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 2921 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 2956 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 2916 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 3015 | 100 |
4" Lead
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 2630 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 2601 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 2558 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 2629 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 2650 | 100 |
Lowest Activity Source Poly Box Attenuation Measurements
Approximately 1.15
Ci at time of measurement, according to ISU Radiation SafetyOpen Source
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 31 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 32 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 26 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 23 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 29 | 100 |
2" Green poly (one brick) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 18 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 27 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 21 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 21 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 22 | 100 |
4" Green poly (two bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 31 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 18 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 19 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 31 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 30 | 100 |
6" Green poly (three bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 35 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 24 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 23 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 21 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 22 | 100 |
8" Green poly (four bricks) in Box
1250V source in | |||||
Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) |
1 | Detector on poly at +1250V | 80 | Yes | 20 | 100 |
2 | Detector on poly at +1250V | 80 | Yes | 28 | 100 |
3 | Detector on poly at +1250V | 80 | Yes | 29 | 100 |
4 | Detector on poly at +1250V | 80 | Yes | 16 | 100 |
5 | Detector on poly at +1250V | 80 | Yes | 22 | 100 |