Difference between revisions of "DF He3 Tube Hardware Setup"
Jump to navigation
Jump to search
| (28 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| − | = | + | __NOTOC__ |
| − | + | =Experimental Setup= | |
| − | *Ortec 142PC Preamplifier | + | [[File:DAF_He3_Tube_Experimental_Setup.png|800px]] |
| − | *Ortec 459 Bias Supply | + | =Electronics= |
| − | *Ortec 672 Spectroscopy Amplifier | + | ==Flowchart== |
| − | *Ortec 871 Timer Counter | + | [[File:DAF_He3_Tube_Plateau_Study_Hardware_Flowchart.png|800px]] |
| − | *CAEN N110 Dual Attenuator | + | ==List== |
| − | *CAEN N841 Leading Edge Discriminator | + | ===He3 tube=== |
| − | *CAEN N93B Dual Timer | + | ====Purpose==== |
| − | *Tektronic DPO 4104 Digital Phosphor Oscilloscope | + | Neutron Detector. Provides the signal of interest. |
| − | = | + | ====Inputs==== |
| − | [[ | + | *None |
| + | ====Outputs==== | ||
| + | *Signal | ||
| + | ====Settings==== | ||
| + | *None | ||
| + | ===Ortec 142PC Preamplifier=== | ||
| + | ====Purpose==== | ||
| + | Amplifies the signal above the noise level. | ||
| + | ====Inputs==== | ||
| + | *Power | ||
| + | *Signal | ||
| + | *Bias | ||
| + | ====Outputs==== | ||
| + | *Time Signal | ||
| + | *Energy Signal | ||
| + | ====Settings==== | ||
| + | *None | ||
| + | ===Ortec 459 Bias Supply=== | ||
| + | ====Purpose==== | ||
| + | Provides the bias voltage to the preamp. | ||
| + | ====Inputs==== | ||
| + | *None | ||
| + | ====Outputs==== | ||
| + | *Bias Supply | ||
| + | ====Settings==== | ||
| + | *Output Voltage | ||
| + | ===Ortec 672 Spectroscopy Amplifier=== | ||
| + | ====Purpose==== | ||
| + | Amplify, shape, and invert the signal. | ||
| + | ====Inputs==== | ||
| + | *Norm | ||
| + | *Diff Ref | ||
| + | ====Outputs==== | ||
| + | *Unipolar | ||
| + | *Bipolar | ||
| + | ====Settings==== | ||
| + | *Coarse Gain | ||
| + | *Fine Gain | ||
| + | *Uni Shaping | ||
| + | *Shaping Time | ||
| + | *PZ | ||
| + | *BLR | ||
| + | *Input | ||
| + | ===Ortec 871 Timer Counter=== | ||
| + | ====Purpose==== | ||
| + | Count the signal pulses. | ||
| + | ====Inputs==== | ||
| + | *Positive | ||
| + | *Negative | ||
| + | ====Outputs==== | ||
| + | *None | ||
| + | ====Settings==== | ||
| + | *Base Coefficient | ||
| + | *Power | ||
| + | *Time Base | ||
| + | *Dwell | ||
| + | ===CAEN N110 Dual Attenuator=== | ||
| + | ====Purpose==== | ||
| + | Attenuate the signal into a useful region. | ||
| + | ====Inputs==== | ||
| + | *In | ||
| + | ====Outputs==== | ||
| + | *Out | ||
| + | ====Settings==== | ||
| + | *None | ||
| + | ===CAEN N841 Leading Edge Discriminator=== | ||
| + | ====Purpose==== | ||
| + | Distinguish between signal and noise. | ||
| + | ====Inputs==== | ||
| + | *Channels 0-15 | ||
| + | ====Outputs==== | ||
| + | *Channels 0-15 (NIM Logic Pulse) | ||
| + | ====Settings==== | ||
| + | *Threshold | ||
| + | *Pulse Width | ||
| + | ===CAEN N93B Dual Timer=== | ||
| + | ====Purpose==== | ||
| + | Provide dead time to prevent double counting. | ||
| + | ====Inputs==== | ||
| + | *Start | ||
| + | *Veto | ||
| + | ====Outputs==== | ||
| + | *Out | ||
| + | ====Settings==== | ||
| + | *Coarse Pulse Width | ||
| + | *Fine Pulse Width | ||
| + | ===Tektronic DPO 4104 Digital Phosphor Oscilloscope=== | ||
| + | ====Purpose==== | ||
| + | View hits / troubleshoot system. | ||
| + | ====Inputs==== | ||
| + | *Channels 1-4 | ||
| + | ====Outputs==== | ||
| + | *None | ||
| + | ====Settings==== | ||
| + | *Too many to put here. | ||
| + | |||
| + | =Main Page= | ||
| + | [[User:Friadavi]] | ||
Latest revision as of 17:36, 29 June 2018
Experimental Setup
Electronics
Flowchart
List
He3 tube
Purpose
Neutron Detector. Provides the signal of interest.
Inputs
- None
Outputs
- Signal
Settings
- None
Ortec 142PC Preamplifier
Purpose
Amplifies the signal above the noise level.
Inputs
- Power
- Signal
- Bias
Outputs
- Time Signal
- Energy Signal
Settings
- None
Ortec 459 Bias Supply
Purpose
Provides the bias voltage to the preamp.
Inputs
- None
Outputs
- Bias Supply
Settings
- Output Voltage
Ortec 672 Spectroscopy Amplifier
Purpose
Amplify, shape, and invert the signal.
Inputs
- Norm
- Diff Ref
Outputs
- Unipolar
- Bipolar
Settings
- Coarse Gain
- Fine Gain
- Uni Shaping
- Shaping Time
- PZ
- BLR
- Input
Ortec 871 Timer Counter
Purpose
Count the signal pulses.
Inputs
- Positive
- Negative
Outputs
- None
Settings
- Base Coefficient
- Power
- Time Base
- Dwell
CAEN N110 Dual Attenuator
Purpose
Attenuate the signal into a useful region.
Inputs
- In
Outputs
- Out
Settings
- None
CAEN N841 Leading Edge Discriminator
Purpose
Distinguish between signal and noise.
Inputs
- Channels 0-15
Outputs
- Channels 0-15 (NIM Logic Pulse)
Settings
- Threshold
- Pulse Width
CAEN N93B Dual Timer
Purpose
Provide dead time to prevent double counting.
Inputs
- Start
- Veto
Outputs
- Out
Settings
- Coarse Pulse Width
- Fine Pulse Width
Tektronic DPO 4104 Digital Phosphor Oscilloscope
Purpose
View hits / troubleshoot system.
Inputs
- Channels 1-4
Outputs
- None
Settings
- Too many to put here.