Difference between revisions of "8-07-2017"
Jump to navigation
Jump to search
(Created page with "2nCor_44#Aug_2017 =Run list= {| border="1" ! Run # !!Charge/pulse !!Target!! Configuration !! Individual histos + rates !! overlayed histos !! no top bottom coin. !! other …") |
|||
Line 13: | Line 13: | ||
| 6513-6517 ||Integral= pV*s 260 mV peak = 1.1A || '''Al''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz || || | | 6513-6517 ||Integral= pV*s 260 mV peak = 1.1A || '''Al''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz || || | ||
|- | |- | ||
− | | 6518 ||Integral= pV*s 260 mV peak = 1.1A || '''MT''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz , Faraday cup in place|| || | + | | 6518 ||Integral= pV*s 260 mV peak = 1.1A || '''MT''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz , '''Faraday cup in place'''|| || |
|- | |- | ||
| 6519 ||Integral= pV*s 260 mV peak = 1.1A || '''D20''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz, This D2O target is a vial and not the bottle used previously || [[File:R6519.png|230px]] || | | 6519 ||Integral= pV*s 260 mV peak = 1.1A || '''D20''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz, This D2O target is a vial and not the bottle used previously || [[File:R6519.png|230px]] || | ||
Line 23: | Line 23: | ||
| 6523 ||Integral= 260 pV*s 260 mV peak = 1.1A || '''DU-238 R45020 ''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz ||[[File:R6523.png|230px]] || || | | 6523 ||Integral= 260 pV*s 260 mV peak = 1.1A || '''DU-238 R45020 ''' || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz ||[[File:R6523.png|230px]] || || | ||
|- | |- | ||
− | | 6524 ||Integral= 280 pV*s 260 mV peak = 1.1A || | + | | 6524 ||Integral= 280 pV*s 260 mV peak = 1.1A || DU-238 R45020 || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. '''For detector at 54 degrees, lowered HV from 1450 to 1400 on both tubes.''' ||[[File:R6524.png|230px]] || || || |
|- | |- | ||
− | | 6525 ||Integral= 270 pV*s 260 mV peak = 1.1A || | + | | 6525 ||Integral= 270 pV*s 260 mV peak = 1.1A || DU-238 R45020 || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. '''For detector at 102 degrees, lowered HV from 1400 to 1350 on bottom tube, covered hole in beam dump for laser with 2" thick Pb.''' ||[[File:R6525.png|230px]] || [[file:R6524-R6525Overlay.png|230px]] || [[File:R6525NoTopBotCoinc.png|230px]] |
|- | |- | ||
− | | 6526 ||Integral= 275 pV*s 260 mV peak = 1.1A || | + | | 6526 ||Integral= 275 pV*s 260 mV peak = 1.1A || DU-238 R45020 || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. '''For detector at 102 degrees, lowered HV from 1350 to 1300 on bottom tube, detector 54 degrees lowered bottom PMT from 1400 to 1350''' || || || ||[[File:6526Linear.png|230px]] |
|- | |- | ||
− | | 6527 ||Integral= pV*s 260 mV peak = 1.1A || | + | | 6527 ||Integral= pV*s 260 mV peak = 1.1A || DU-238 R45020 || 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. || || || ||[[File:6527Linear.png|230px]] |
|- | |- | ||
− | | 6528 || Cosmic Run, Bean tuning last 20 minutes, No target in cell || MT | + | | 6528 || '''Cosmic Run, Bean tuning last 20 minutes, No target in cell''' || '''MT ''' || [[File:R6528.png|230px]] || || || ||[[File:6528Linear.png|230px]] |
|} | |} | ||
[[2nCor_44#Aug_2017]] | [[2nCor_44#Aug_2017]] |
Latest revision as of 19:30, 10 August 2017
Run list
Run # | Charge/pulse | Target | Configuration | Individual histos + rates | overlayed histos | no top bottom coin. | other |
---|---|---|---|---|---|---|---|
6510 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | ||||
6511 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | ||||
6512 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | ||||
6513-6517 | Integral= pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | ||||
6518 | Integral= pV*s 260 mV peak = 1.1A | MT | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz , Faraday cup in place | ||||
6519 | Integral= pV*s 260 mV peak = 1.1A | D20 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz, This D2O target is a vial and not the bottle used previously | ||||
6521 | Integral= 255+-15 pV*s 260 mV peak = 1.1A | Al | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | ||||
6522 | Integral= 255 pV*s 260 mV peak = 1.1A | MT | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | ||||
6523 | Integral= 260 pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz | ||||
6524 | Integral= 280 pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 54 degrees, lowered HV from 1450 to 1400 on both tubes. | ||||
6525 | Integral= 270 pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 102 degrees, lowered HV from 1400 to 1350 on bottom tube, covered hole in beam dump for laser with 2" thick Pb. | ||||
6526 | Integral= 275 pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. For detector at 102 degrees, lowered HV from 1350 to 1300 on bottom tube, detector 54 degrees lowered bottom PMT from 1400 to 1350 | ||||
6527 | Integral= pV*s 260 mV peak = 1.1A | DU-238 R45020 | 10.5 MeV (1108 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 180 Hz. | 230px | |||
6528 | Cosmic Run, Bean tuning last 20 minutes, No target in cell | MT | 230px |