Difference between revisions of "Phase space Limiting Particles"
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
<center><math>\textbf{\underline{Navigation}}</math> | <center><math>\textbf{\underline{Navigation}}</math> | ||
− | [[ | + | [[Center_of_Mass_for_Stationary_Target|<math>\vartriangleleft </math>]] |
− | [[VanWasshenova_Thesis# | + | [[VanWasshenova_Thesis#Weighted_Isotropic_Distribution_in_Lab_Frame|<math>\triangle </math>]] |
− | [[ | + | [[Determining_Momentum_Components_After_Collision_in_CM_Frame|<math>\vartriangleright </math>]] |
</center> | </center> | ||
Line 9: | Line 9: | ||
+ | =4.1.2 Phase space Limiting Particles= | ||
Line 22: | Line 23: | ||
Since the momentum in the CM frame is a constant, this implies that pz must decrease. We can use the variable rapidity: | Since the momentum in the CM frame is a constant, this implies that pz must decrease. We can use the variable rapidity: | ||
− | |||
− | |||
− | <center><math> | + | <center><math>y \equiv \frac {1}{2} \ln \left(\frac{E+p_z}{E-p_z}\right)</math></center> |
− | |||
this implies that as | this implies that as | ||
Line 50: | Line 48: | ||
<center><math>p_x^2+p_y^2=52.589054^2+9.272868^2=53.400MeV > 53.015 MeV (E) \therefore p_z \rightarrow imaginary</math></center> | <center><math>p_x^2+p_y^2=52.589054^2+9.272868^2=53.400MeV > 53.015 MeV (E) \therefore p_z \rightarrow imaginary</math></center> | ||
− | These particles are outside the light cone and are more timelike, thus not visible in normal space. This will reduce the | + | These particles are outside the light cone and are more timelike, thus not visible in normal space. This will reduce the range in theta that Moller electrons will be detected. |
+ | |||
+ | |||
+ | |||
+ | ---- | ||
Line 56: | Line 58: | ||
<center><math>\textbf{\underline{Navigation}}</math> | <center><math>\textbf{\underline{Navigation}}</math> | ||
− | [[ | + | [[Center_of_Mass_for_Stationary_Target|<math>\vartriangleleft </math>]] |
− | [[VanWasshenova_Thesis# | + | [[VanWasshenova_Thesis#Weighted_Isotropic_Distribution_in_Lab_Frame|<math>\triangle </math>]] |
− | [[ | + | [[Determining_Momentum_Components_After_Collision_in_CM_Frame|<math>\vartriangleright </math>]] |
</center> | </center> |
Latest revision as of 16:47, 26 July 2017
4.1.2 Phase space Limiting Particles
Since the angle phi has been constrained to remain constant, the x and y components of the momentum will increase in the positive first quadrant. This implies that the z component of the momentum must decrease by the relation:
In the Center of Mass frame, this becomes:
Since the momentum in the CM frame is a constant, this implies that pz must decrease. We can use the variable rapidity:
this implies that as
For forward travel in the light cone:
This corresponds to the scattered electron proven earlier.
For backward travel in the light cone:
Similarly, this corresponds to the Moller electron.
For a particle that transforms from the Lab frame to the CM frame where the particle is not within the light cone:
These particles are outside the light cone and are more timelike, thus not visible in normal space. This will reduce the range in theta that Moller electrons will be detected.