Straight Track Moller Rates
 +
 +
Goal:  Confirm that the  moller Rate (Hz) seen in on a wire agrees with the Rate calculated from the cross section.  The torus is turned off so the wire is more easily correlated with the moller scattering angle.  No need for track reconstruction.
 +
 +
Reproduce the plot below using Torus off
 +
 +
https://wiki.iac.isu.edu/index.php/File:TheoryDCHits.png
 +
 +
 +
[[File:Layer1binWeighted.png]]
 +
 +
 +
 +
Then calculate Rate and compare to the reference.
 +
 
=Determining wire-theta correspondence=
 
=Determining wire-theta correspondence=
 
To associate the hits with the Moller scattering angle theta, the occupancy plots of the drift chamber hits by means of wire numbers and layer must be translated using the physical constraints of the detector.  Using the data released for the DC:
 
To associate the hits with the Moller scattering angle theta, the occupancy plots of the drift chamber hits by means of wire numbers and layer must be translated using the physical constraints of the detector.  Using the data released for the DC:
Line 370: Line 385:
  
 
<center><math>\theta=\arctan{\frac{19.21+n1.212}{243.39-n0.5652}}</math></center>
 
<center><math>\theta=\arctan{\frac{19.21+n1.212}{243.39-n0.5652}}</math></center>
 +
 +
 +
<center><math>\tan{\theta}=\frac{19.21+n1.212}{243.39-n0.5652}\Rightarrow \tan{ \theta}=-2.14437 + \frac{957.412}{430.626 - n}\Rightarrow 430.626 - n = \frac{957.412}{\tan{ \theta}+2.14437}</math></center>
 +
 +
 +
<center><math>\Rightarrow n = \frac{-957.412}{\tan{ \theta}+2.14437}+430.626</math></center>
  
 
Using Mathematica, a series expansion about n=0 can be found:
 
Using Mathematica, a series expansion about n=0 can be found:
Line 394: Line 415:
  
  
<center><math>\theta '\approx 0.293983 + 0.00112727 n - 4.49787\times 10^{-6} n^2</math></center>
 
 
 
<center><math>\theta ''\approx 0.00112727 - 8.99574\times 10^{-6} n</math></center>
 
 
Solving for the maximum,
 
 
<center><math>\Rightarrow 0.00112727 - 8.99574*10^-6 n=0\Rightarrow n=
 
  
 
This tells us that the expression for theta will follow a function that comes from a series expansion.  To account for instrument and measurement errors, angle measurements from ced can be used to find a better fit.
 
This tells us that the expression for theta will follow a function that comes from a series expansion.  To account for instrument and measurement errors, angle measurements from ced can be used to find a better fit.
Line 411: Line 424:
 
Declaring the data set:
 
Declaring the data set:
 
<pre>
 
<pre>
In[1]:= data1={{1,4.79},{2,5.09},{78,29.79},{111,40.50},{112,40.82}}
+
In[1]:= data1={{1,4.79},{2,5.09},{62,24.42},{63,24.76},{64,25.10},{78,29.79},{111,40.50},{112,40.82}}
  
Out[1]= {{1,4.79},{2,5.09},{78,29.79},{111,40.5},{112,40.82}}
+
Out[1]= {{1,4.79},{2,5.09},{62,24.42},{63,24.76},{64,25.1},{78,29.79},{111,40.5},{112,40.82}}
 
</pre>
 
</pre>
  
Line 421: Line 434:
 
In[2]:= line1=Fit[data1,{1,n},n]
 
In[2]:= line1=Fit[data1,{1,n},n]
  
Out[2]= 4.45395 +0.324738 n
+
Out[2]= 4.39975 + 0.32469 n
 
</pre>
 
</pre>
  
Line 460: Line 473:
 
In[3]:= quad1=Fit[data1,{1,n,n^2},n]
 
In[3]:= quad1=Fit[data1,{1,n,n^2},n]
  
Out[3]= 4.45253 +0.325072 n-3.05048*10^-6 n^2
+
Out[3]= 4.45564 +0.32015 n+0.0000417787 n^2
 
</pre>
 
</pre>
  
Line 471: Line 484:
 
Testing for a polynomial of degree 3 fit:
 
Testing for a polynomial of degree 3 fit:
 
<pre>
 
<pre>
In[118]:= polynomial1=Fit[data1,{1,n,n^2,n^3},n]
+
In[4]:= polynomial1=Fit[data1,{1,n,n^2,n^3},n]
  
Out[118]= 4.48739 +0.300911 n+0.000510988 n^2-2.6919*10^-6 n^3
+
Out[4]= 4.49876 +0.293001 n+0.000679074 n^2-3.57132*10^-6 n^3
 
</pre>
 
</pre>
  
Line 479: Line 492:
 
This fit best matches the data found in ced
 
This fit best matches the data found in ced
  
<center><math>\theta\equiv 4.48739 +0.300911 n+0.000510988 n^2-2.6919\times 10^{-6} n^3</math></center>
+
<center><math>\theta\equiv 4.49876 +0.293001 n+0.000679074 n^2-3.57132\times 10^{-6} n^3</math></center>
  
 
As discussed earlier, taking the 1st derivative of this function will give us the spacing of the bins as a function of wire number.
 
As discussed earlier, taking the 1st derivative of this function will give us the spacing of the bins as a function of wire number.
  
<center><math>\theta '\equiv .300911+0.00102197 n-8.0757\times 10^{-6} n^2</math></center>
+
<center><math>\theta '\equiv 0.293001 + 0.00135815 n - 0.000010714 n^2</math></center>
  
  
Line 491: Line 504:
  
  
<center><math>.001021976-1.61514\times 10^{-5} n=0\Rightarrow Bin\ Spacing\ Maximum\ at\ n=63.2748</math></center>
+
<center><math>0.00135815 - 0.0000214279 n=0\Rightarrow Bin\ Spacing\ Maximum\ at\ n=63.3822</math></center>
 +
 
 +
Comparing this maximum, we can see from Table 3 that near the maximum of 63 are seperated by larger distances than at n=1 or n=112.  This is the midpoint of the plane as seen in the geometry file.
 +
 
 +
===Binning based on wire numbers===
 +
 
 +
The bin size based on wire number will need to be a uniform width of 1, as in an increment of 1 between the integer values of the wires.  This uniformity in bin size based on wire numbers is not uniform when viewed by the angle theta due to the Drift Chamber geometry discussed earlier.
 +
 
 +
Modifying evioreader
 +
 
 +
 
 +
<center>[[File:Layer1bins.png]]</center>
 +
 
 +
<center>[[File:Layer1bins_Isotropic.png]]</center>
 +
 
 +
<pre>
 +
gStyle->SetStripDecimals(kTRUE);
 +
TF1 *fit_function=new TF1("fit_function","[0]+[1]*x+[2]*x*x+[3]*x*x*x",4.49876,41.12592);
 +
fit_function->SetParameters(4.49876,0.293001,0.000679074,-0.00000357132);
 +
TGaxis *A1 = new TGaxis(0,5000,113,5000,"fit_function",510,"-");
 +
A1->SetTitle("Angle Theta(degrees)");
 +
A1->Draw();
 +
</pre>
 +
 
 +
 
 +
<center>[[File:Layer1binWeighted.png]][[File:MolThetaLabWeighted.png]]</center>
 +
 
 +
 
 +
<center>[[File:Layer1binWeighted_Isotropic.png]][[File:MolThetaLabWeighted2.png]]</center>
 +
 
 +
Using the expression for n in terms of Theta:
 +
 
 +
<center><math>n = \frac{-957.412}{\tan{ \theta}+2.14437}+430.626</math></center>
 +
 
 +
 
 +
This relationship can be used to multiply each Moller Scattering angle theta in the lab frame, with it's differential cross-section weight, to find the Moller differential cross-section as a function of wire number in the lab frame.
 +
 
 +
 
 +
<center>[[File:MolThetaWireWeighted.png]][[File:MolThetaWireWeightedIsotropic.png]]</center>
 +
 
 +
 
 +
<center>[[File:MolThetaWireWeightedAdjusted.png]][[File:MolThetaWireWeightedAdjustedIsotropic.png]]</center>
 +
 
 +
 
 +
<center>[[File:TheoryDCbinsWire.png]][[File:TheoryDCbinsWireIsotropic.png]]</center>
 +
 
 +
=Moller Occupancy Rate=
 +
 
 +
 
 +
==Comparing Rates==
 +
Using the values from Whitney:
 +
 
 +
<center>[[File:Whitney_values.png‎]]</center>
 +
 
 +
For a 5cm target of LH2:
 +
 
 +
<center><math>\rho_{target}\times l_{target}=\frac{70.85 kg}{1 m^3}\times \frac{1 mole}{2.02 g} \times \frac{1000g}{1 kg} \times \frac{6.022\times10^{23} molecules\ LH_2}{1 mole} \frac{2 atoms}{1\ molecule\ LH_2} \times \frac{1m^3}{(100 cm)^3} \times \frac{5 cm}{ }=2.11\times 10^{23} \times \frac{10^{-24} cm^{2}}{barn}=2.11\times 10^{-1}\ barns^{-1}</math></center>
 +
 
 +
 
 +
Using the beam current of 100nA,
 +
 
 +
<center><math>\Phi_{beam}=\frac{100\times 10^{-9}\ A}{1} \times \frac{1\ C}{1\ A} \times \frac{1\ e^{-}}{1\ s} \times \frac{1}{1.602\times 10^{-19}C}\Rightarrow 6.2422\times 10^{11}\ \frac{1}{s}=\Phi_{e^{-}}</math></center>
 +
 
 +
 
 +
Given the beam Luminosity of:
 +
<center><math>\mathcal {L}=\frac{1.32\times 10^{35}}{cm^2 \cdot s}\frac{10^{-24} cm^{2}}{barn}=\frac{1.32\times 10^{11}}{barn\cdot s}=\Phi_{beam}\ \rho\ l_{target}</math></center>
 +
 
 +
We can check to make sure the density makes sense
 +
 
 +
<center><math>\Rightarrow \rho_{target}=\frac{1.32\times 10^{35}}{ \Phi_{beam}\ l_{target}cm^2 \cdot s}=\frac{1.32\times 10^{35}}{ 6.24\times 10^{11}\  \cdot 5cm^3}=\frac{4.23\times 10^{22}}{cm^3}</math></center>
 +
 
 +
 
 +
<center><math>\Rightarrow \rho_{target}=\frac{70.85 kg}{1 m^3}\times \frac{1 mole}{2.02 g} \times \frac{1000g}{1 kg} \times \frac{6.022\times10^{23} molecules\ LH_2}{1 mole} \times \frac{1m^3}{(100 cm)^3}\frac{2 atoms}{1\ molecule\ LH_2}=\frac{4.23\times 10^{22}}{cm^3}</math></center>
 +
 
 +
 
 +
Using the values from Whitney :
 +
 
 +
 
 +
https://wiki.iac.isu.edu/index.php/CLAS12_RateEst_byWA
 +
 
 +
{| class="wikitable" align="center" border=1
 +
|+ '''Rates'''
 +
|-
 +
| Energy || 6 GeV || 11 GeV
 +
|-
 +
|Process || (nb) || (nb)
 +
|-
 +
|Moller || 22773001||75008636
 +
|-
 +
| DIS + radiative tail  || 128 || 83
 +
|-
 +
| Elastic e-p || 5511220 ||3670740
 +
|-
 +
|Elastic radiative tail || 24705 || 12944
 +
|-
 +
| π0 electro-production || 14802 ||17908
 +
|-
 +
| π0 photo-production || 569 || 852
 +
|-
 +
| π+ electro-production || 4032 || 5536
 +
|-
 +
| π+ photo-production || 282 || 487
 +
|-
 +
|  π− electro-production ||  2806 || 3843
 +
|-
 +
|  π− photo-production || 199 || 342
 +
|-
 +
|  Total || 2.83317E7 || 7.87214E7
 +
|}
 +
 
 +
 
 +
 
 +
     
 +
<center><math>R_{events}= \sigma_{events} \mathcal{L}=7.87\times 10^{-2}\ barn\ \cdot \frac{1.33\times 10^{11}}{barn\cdot s}=\frac{1.05\times 10^{10}events}{s}</math></center>
 +
 
 +
 
 +
 
 +
<center><math>R_{Moller}= \sigma_{Moller} \mathcal{L}=7.50\times 10^{-2}\ barn\ \cdot \frac{1.33\times 10^{11}}{barn\cdot s}=\frac{9.97\times 10^{9}Moller}{s}</math></center>
 +
 
 +
 
 +
 
 +
[[File:CLAS12ExpWS_WA.pdf]]
 +
 
 +
<center>[[File:Whitney_2.png]][[File:Whitney_3.png]]</center>
 +
 
 +
 
 +
<center>[[File:Whitney_4.png]]</center>
 +
 
 +
 
 +
<center><math>\sigma=\frac{R}{\mathcal{L}}=\frac{dN}{dt}\cdot \frac{1}{\mathcal{L}}</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\Rightarrow \int\limits_{0}^{t}\, dt=\int\limits_{0}^{N}\frac{1}{\sigma \mathcal{L}}\, dN</math></center>
 +
 
 +
 
 +
<center><math>t_{simulated}=\frac{N_{events}}{\sigma_{events} \Phi \rho \ell}=\frac{1000000\ barn \cdot s}{7.87\times 10^{-2} \cdot 1.33\times 10^{11}\ barn}=9.54\times 10^{-5} s</math></center>
 +
 
 +
 
 +
 
 +
 
 +
 
 +
<center><math>N_0=\Delta t \cdot R_{events}=\Delta t \cdot \frac{N_{events}}{t_{simulated}}=500\times 10^{-9}\ s \cdot \frac{1\times 10^6}{0.0954\times 10^{-3}\ s}=5240</math></center>
 +
 
 +
 
 +
<center><math>Occupancy=\frac{N_{hits}}{N_0}=\frac{N_{hits}}{\Delta t \cdot R_{events}}=\frac{t_{simulated}\cdot N_{hits}}{N_{events}\cdot \Delta t}=</math></center>
 +
 
 +
Similarly,
 +
 
 +
 
 +
<center><math>N_{events} =R_{events}\cdot t_{simulated}=\frac{1.05\times 10^{10}events}{s} \cdot 9.54\times 10^{-5} s=1001700\ events</math></center>
 +
 
 +
 
 +
<center><math>N_{Moller} =R_{Moller}\cdot t_{simulated}=\frac{9.97\times 10^{9}Moller}{s} \cdot 9.54\times 10^{-5} s=951138\ Moller</math></center>
 +
 
 +
 
 +
<center><math>\sigma=\frac{N_{events}}{N_{incident}}\frac{1}{\rho \ell}\Rightarrow N_{incident}=\frac{N_{events}}{\sigma \rho \ell}=\frac{951138}{.075\cdot 2.11\times 10^{-1}}=6\times 10^7\ incident </math></center>
 +
 
 +
 
 +
 
 +
<center><math>\left ( \frac{Number\ of\ hits}{Moller\ electron}\right ) \left (\frac{Moller\ electrons}{incidents\ electron} \right) \left (\frac{incident\ electrons}{sec} \right )</math></center>
 +
 
 +
==GEANT Simulations==
 +
https://wiki.iac.isu.edu/index.php/Converting_to_barns
 +
 
 +
https://wiki.iac.isu.edu/index.php/Check_Differential_Cross-Section
 +
 
 +
Converting the number of electrons scattered per angle theta to barns, we can use the relation
 +
 
 +
<center><math>\mathcal{L}=\frac{R_{scattered}}{\sigma} = \Phi_{beam}\ \rho\ \ell </math></center>
 +
 
 +
 
 +
 
 +
<center><math>\sigma=\frac{R_{scattered}}{\mathcal{L}} =\frac{R_{scattered}}{\Phi_{beam}\ \rho\ \ell}= \frac{R_{scattered}}{R_{incident}\ \rho\ \ell}=\frac{N_{scattered}}{\Delta t}\cdot \frac{\Delta t}{N_{incident}}\cdot \frac{1}{\rho \ell}</math></center>
 +
 
 +
If the time is taken to be the  same for the amount scattered as for the amount incident (the time simulated), this can be viewed as the probability of one incident electron producing a Moller event.
 +
 
 +
 
 +
 
 +
<center><math>\sigma=\frac{N_{scattered}}{N_{incident}}\frac{1}{\rho \ell}</math></center>
 +
 
 +
 
 +
While this expression has no explicit dependancies on energy, the ratio is a function of the energy, as well as the physical makeup of the target.
 +
 
 +
This gives, for LH2:
 +
 
 +
<center><math>\rho_{target}\times l_{target}=\frac{70.85 kg}{1 m^3}\times \frac{1 mole}{2.02 g} \times \frac{1000g}{1 kg} \times \frac{6\times10^{23} molecule}{1 mole} \times \frac{2\ atoms}{molecule}\times \frac{1m^3}{(100 cm)^3} \times \frac{1 cm}{ } \times \frac{10^{-24} cm^{2}}{barn} =4.2\times 10^{-2} barns^{-1}</math></center>
 +
 
 +
 
 +
 
 +
From earlier simulations for random angle Phi, we know that the full range of Theta is limited depending on the target material.
 +
 
 +
 
 +
<center>[[File:MollerThetaLab_4e7_LH2_11GeV.png]][[File:MollerThetaLab_4e7_NH3_11GeV.png]]</center>
 +
 
 +
 
 +
<center>[[File:MollerThetaLab_4e7_LH2_11GeV_Detector.png]][[File:MollerThetaLab_4e7_NH3_11GeV_Detector.png]]</center>
 +
 
 +
 
 +
<center><math>\sigma = \frac{N_{events}}{N_{incident}\ \rho\ \ell}=\frac{975593}{40000000\ \cdot 4.2\times 10^{-2} barns^{-1}}=\frac{0.024}{4.2\times 10^{-2} barns^{-1}}=0.58 barns</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\sigma=\frac{R_{events}}{\mathcal{L}} \Rightarrow \mathcal{L}=\frac{R_{events}}{\sigma}</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\mathcal{L}=\frac{dN_{events}}{dt}\frac{1}{ \sigma}\Rightarrow \int_{0}^{t_{simulated}}\mathcal {L}\, dt= \int_{0}^{N_{events}}\frac{1}{\sigma}\, dN</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\mathcal{L} \cdot t_{simulated}=\frac{N_{events}}{\sigma}</math></center>
 +
 
 +
 
 +
For a Luminosity of <math>\mathcal{L}=\frac{1.3\times 10^{11}}{barn\cdot s}</math>
 +
 
 +
 
 +
 
 +
<center><math>\frac{1.3\times 10^{11}}{barn\cdot s} \cdot t_{simulated}=\frac{975593}{.58\ barn}</math></center>
 +
 
 +
 
 +
 
 +
<center><math>t=1.3\times 10^{-5}\ s</math></center>
 +
 
 +
 
 +
===Comparison of GEANT Simulation to Whitney Data===
 +
 
 +
 
 +
{| class="wikitable" align="center" border=1
 +
|+ '''Rates'''
 +
|-
 +
| Simulation || GEANT4 ||  Whitney
 +
|-
 +
| Event Cross-Section (nb) || .61 || 0.079
 +
|-
 +
|Moller Cross-Section (nb) || 0.58||0.075
 +
|-
 +
| Length of Target (cm)  || 1 || 5
 +
|-
 +
| t_{simulated} (s) || 1.3E-5 ||9.54E-5
 +
|-
 +
| N_{events} || 1026940 || 1001700
 +
|-
 +
| N_{Moller} || 975593 ||951138
 +
|-
 +
| N_{incident} || 4E7 || 6E7
 +
|}
 +
 
 +
 
 +
Moller events occur for about 2.5% of the incident electrons on a LH2 target.  We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well.  Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material
 +
 
 +
==Isotropic Weighted Distribution==
 +
===Isotropic in CM===
 +
Assuming a 1cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,
 +
 
 +
<pre>
 +
TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
 +
Combo->Add(Layer1binsWeighted,23.8);
 +
Combo->Draw();
 +
</pre>
 +
 
 +
<center>[[File:Layer1binsMollerRate.png]]</center>
 +
 
 +
 
 +
 
 +
<center><math>\frac{2003912\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=6.68\times 10^6\ Moller\ electrons</math></center>
 +
 
 +
 
 +
<center><math>\frac{6.68\times 10^6\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=3.34\times 10^8\ Incident\ electrons</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{4.2\times 10^{-2}}=.48\ barn</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\mathcal{L}=N_{incident}\ \rho \ell=3.34\times 10^8\ Incident\ electrons \cdot 4.2\times 10^{-2}=\frac{1.40\times 10^{7}\ electrons}{barn \cdot s}</math></center>
 +
 
 +
 
 +
Assuming a 5cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,
 +
 
 +
<pre>
 +
TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
 +
Combo->Add(Layer1binsWeighted,4.76);
 +
Combo->Draw();
 +
</pre>
 +
 
 +
<center>[[File:Layer1binsMollerRate_2.png]]</center>
 +
 
 +
 
 +
 
 +
<center><math>\frac{400782\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=1.34\times 10^6\ Moller\ electrons</math></center>
 +
 
 +
 
 +
<center><math>\frac{1.34\times 10^6\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=6.67\times 10^7\ Incident\ electrons</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{2.1\times 10^{-1}}=.095\ barn</math></center>
 +
 
 +
 
 +
<center><math>\mathcal{L}=N_{incident}\ \rho \ell=6.67\times 10^7\ Incident\ electrons \cdot 2.1\times 10^{-1}=\frac{1.40\times 10^{7}\ electrons}{barn \cdot s}</math></center>
 +
 
 +
===Isotropic in Lab===
 +
Assuming a 1cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,
 +
 
 +
<pre>
 +
TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
 +
Combo->Add(Layer1binsWeighted,23.8);
 +
Combo->Draw();
 +
</pre>
 +
 
 +
<center>[[File:Layer1binsMollerRateIsotropic.png]]</center>
 +
 
 +
 
 +
 
 +
<center><math>\frac{833000\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=2.78\times 10^6\ Moller\ electrons</math></center>
 +
 
 +
 
 +
<center><math>\frac{2.78\times 10^6\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=1.39\times 10^8\ Incident\ electrons</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{4.2\times 10^{-2}}=.48\ barn</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\mathcal{L}=N_{incident}\ \rho \ell=3.34\times 10^8\ Incident\ electrons \cdot 4.2\times 10^{-2}=\frac{5.83\times 10^{6}\ electrons}{barn \cdot s}</math></center>
 +
 
 +
 
 +
Assuming a 5cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,
 +
 
 +
<pre>
 +
TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
 +
Combo->Add(Layer1binsWeighted,4.76);
 +
Combo->Draw();
 +
</pre>
 +
 
 +
<center>[[File:Layer1binsMollerRate_2Isotropic.png]]</center>
 +
 
 +
 
 +
 
 +
<center><math>\frac{166600\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=5.55\times 10^5\ Moller\ electrons</math></center>
 +
 
 +
 
 +
<center><math>\frac{5.55\times 10^5\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=2.78\times 10^7\ Incident\ electrons</math></center>
 +
 
 +
 
 +
 
 +
<center><math>\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{2.1\times 10^{-1}}=.095\ barn</math></center>
 +
 
  
Comparing this maximum, we can see from Table 3 that near the maximum of 63(the points near 78) are seperated by larger distances than at n=1 or n=112.
+
<center><math>\mathcal{L}=N_{incident}\ \rho \ell=6.67\times 10^7\ Incident\ electrons \cdot 2.1\times 10^{-1}=\frac{5.83\times 10^{6}\ electrons}{barn \cdot s}</math></center>
  
 
=[[DV_RunGroupC_Moller#Wire_angle_correspondance|back]]=
 
=[[DV_RunGroupC_Moller#Wire_angle_correspondance|back]]=

Latest revision as of 07:27, 30 December 2016

Straight Track Moller Rates

Goal: Confirm that the moller Rate (Hz) seen in on a wire agrees with the Rate calculated from the cross section. The torus is turned off so the wire is more easily correlated with the moller scattering angle. No need for track reconstruction.

Reproduce the plot below using Torus off

https://wiki.iac.isu.edu/index.php/File:TheoryDCHits.png


Layer1binWeighted.png


Then calculate Rate and compare to the reference.

Determining wire-theta correspondence

To associate the hits with the Moller scattering angle theta, the occupancy plots of the drift chamber hits by means of wire numbers and layer must be translated using the physical constraints of the detector. Using the data released for the DC:

DC: Drift Chambers(specs)

DC Geometry(geom)

Wires parallel all types.png

Examining the geometry file, we can see that each plane, not just the plane of the sense wires, is separated by a distance of D=.3861 cm. We can use the geometry of the wire placements to find

[math]\alpha=\frac{D}{\cos(60^{\circ})}=2D[/math]


Finding the separation distance between two adjacent sense wires

[math]d=4(.3861\ cm)\cos(30^{\circ})=1.337\ cm[/math]


Hex.png


Since the separation between adjacent sense wires is uniform and at a set angle of 25 degrees with respect to the beam line, we can use this fact to determine the angle theta each wire makes when measured from the vertex.

DC geom.png


[math]\Delta\ x=1.337\cos(25^{\circ})cm=1.212cm[/math]


[math]\Delta\ z=-1.337\sin(25^{\circ})cm=-0.5652cm[/math]


The new x and z coordinates for wire 2 can be found using the change in the components

[math]x'=x+\Delta x[/math]
[math]z'=z+\Delta z[/math]


This can be extended to any point along the same wire plane, starting from the coordinates for wire 1

[math]x'=x+\Delta x\times\ n[/math]
[math]z'=z+\Delta z\times\ n[/math]

The angle theta that the wire makes with the vertex is given by

[math]\tan{\theta}=\frac{x+\Delta x}{z+\Delta z}\Rightarrow \theta=\arctan{\frac{x+\Delta x}{z+\Delta z}}[/math]

CED Verification

Using CED to verify the angle and wire correlation,


Zooming in on the view paralell to the direction of the wires in ced, we can examine the wire corresponding theta angle in the drift chamber.

ParallelWireZoom.png


Table 1: Superlayer 1 Wire 1 Coordinates
Coordinates(cm) Layer 1 Layer 2 Layer 3 Layer 4 Layer 5 Layer 6
x 20.42 21.51 21.39 22.49 22.37 23.47
y 0.00 0.00 0.00 0.00 0.00 0.00
z 243.41 244.18 245.51 246.28 247.62 248.38
Table 2: Superlayer 1 Wire 2 Coordinates
Coordinates(cm) Layer 1 Layer 2 Layer 3 Layer 4 Layer 5 Layer 6
x 21.64 22.73 22.61 23.71 23.58 24.69
y 0.00 0.00 0.00 0.00 0.00 0.00
z 242.86 243.62 244.94 245.71 247.05 247.81

Corresponding theta angles can be found for other wires, in Region 1, Superlayers 1 and 2.

Table 3: Superlayer 1 Wire-Angle Theta Correspondence in Degrees
Wire Number Layer 1 Layer 2 Layer 3 Layer 4 Layer 5 Layer 6
1 4.79 5.03 4.98 5.22 5.16 5.40
2 5.09 5.33 5.27 5.51 5.45 5.69
62 24.42
63 24.76
64 25.10
77 29.46 29.60 29.41 29.55 29.37 29.51
78 29.79 29.93 29.74 29.88 29.69 29.83
79 30.12 30.26 30.07 30.21 30.02 30.16
110 40.19 40.28 40.05 40.13 39.91 39.99
111 40.51 40.59 40.36 40.44 40.21 40.29
112 40.82 40.90 40.67 40.75 40.52 40.60


Table 4: Superlayer 2 Wire-Angle Theta Correspondence in Degrees
Wire Number Layer 1 Layer 2 Layer 3 Layer 4 Layer 5 Layer 6
1 4.79 5.03 4.98 5.22 5.16 5.40
2 5.09 5.33 5.27 5.51 5.45 5.69
77 29.46 29.60 29.41 29.56 29.37 29.51
78 29.79 29.93 29.74 29.88 29.70 29.84
79 30.13 30.27 30.07 30.21 30.02 30.16
110x 40.19 40.28 40.05 40.13 39.91 39.99
111 40.51 40.59 40.36 40.44 40.22 40.30
112 40.82 40.90 40.67 40.75 40.52 40.60

Super Layer 1:Layer 1

Table 1: Superlayer 1 Change of Coordinates From Wire 1 to Wire 2(cm)
Coordinates(cm) Layer 1 Layer 2 Layer 3 Layer 4 Layer 5 Layer 6
[math]\Delta x[/math] 1.22 1.22 1.22 1.22 1.21 1.22
[math]\Delta y[/math] 0.00 0.00 0.00 0.00 0.00 0.00
[math]\Delta z[/math] .55 .56 .57 .57 .57 .57


Using the geometric construction for determining angle theta to wire 2:

[math]\tan{\theta}=\frac{x+\Delta x}{z+\Delta z}\Rightarrow \theta=\arctan{\frac{x+\Delta x}{z+\Delta z}}[/math]


[math]\arctan{\frac{20.42+1.212}{243.39-0.5652}}=\arctan{\frac{21.632}{242.8248}}=\arctan{0.0891}=5.09^{\circ}[/math]


This equation can be solved for a hypothetical wire 0, which will allow the wire number to be the multiplicative factor for the change from the starting position.


[math]\tan{\theta}=\frac{x-\Delta x+n\Delta x}{z-\Delta z+n\Delta z}\Rightarrow \theta=\arctan{\frac{x'+n\Delta x}{z'+n\Delta z}}[/math]

where

[math]x'=20.42-1.212\approx 19.21cm[/math]
[math]z'=243.39+0.5652\approx 243.96cm[/math]


[math]\theta=\arctan{\frac{19.21+n1.212}{243.39-n0.5652}}[/math]


[math]\tan{\theta}=\frac{19.21+n1.212}{243.39-n0.5652}\Rightarrow \tan{ \theta}=-2.14437 + \frac{957.412}{430.626 - n}\Rightarrow 430.626 - n = \frac{957.412}{\tan{ \theta}+2.14437}[/math]


[math]\Rightarrow n = \frac{-957.412}{\tan{ \theta}+2.14437}+430.626[/math]

Using Mathematica, a series expansion about n=0 can be found:

In[1]:= Series[ArcTan[(19.21+1.212 x)/(243.39-0.5652 n)],{n,0,4}]

Out[1]= 0.0787635+0.00513098 n+9.83726*10^-6 n^2-2.61675*10^-8 n^3-2.22826*10^-10 n^4+O[n]^5
[math]\theta\approx 0.0787635+0.00513098 n+9.83726\times 10^{-6} n^2-2.61675\times 10^{-8} n^3[/math]


This expression will find the angle theta in radians given the wire number. To convert from radians to degrees, we can multiply by 180 and divide by Pi.

In[2]:= 180*(0.07876354504106763`+0.005130982891104289` n+9.837257652182922`*^-6 n^2-2.616751708660921`*^-8 n^3-2.2282595631625944`*^-10 n^4+O[n]^5)/3.14159625359

Out[2]= 4.51281+0.293983 n+0.000563633 n^2-1.49929*10^-6 n^3-1.2767*10^-8 n^4+O[n]^5


[math]\theta\approx 4.51281+0.293983 n+0.000563633 n^2-1.49929\times10^{-6} n^3[/math]


This tells us that the expression for theta will follow a function that comes from a series expansion. To account for instrument and measurement errors, angle measurements from ced can be used to find a better fit.


Using Mathematica, a line can be fitted to the data collected on the wire number to angle theta correspondence.


Declaring the data set:

In[1]:= data1={{1,4.79},{2,5.09},{62,24.42},{63,24.76},{64,25.10},{78,29.79},{111,40.50},{112,40.82}}

Out[1]= {{1,4.79},{2,5.09},{62,24.42},{63,24.76},{64,25.1},{78,29.79},{111,40.5},{112,40.82}}


Testing for a linear fit:

In[2]:= line1=Fit[data1,{1,n},n]

Out[2]= 4.39975 + 0.32469 n

Examing the range limits for the angle theta for layer 1:


Taking the difference of the upper and lower limits in theta,

[math]\Delta degrees=40.82^{\circ}-4.79^{\circ}=36.03^{\circ}[/math]


Dividing by the change in wire numbers (112-1=111), we find

[math]\frac{\Delta degrees}{\Delta wire\ number}=\frac{36.03^{\circ}}{111\ wires}\approx\ \frac{0.325^{\circ}}{wire\ number}[/math]

This would imply that if the wires were evenly placed, their change in angle theta would increase by the factor of .325 degrees for each increase in wire number, starting obviously with wire 1 at 4.79 degrees. In addition, this implies that the bin spacing for each wire would be around .325 degrees in width.


Chercking this, we can find the difference between wires 1 and 2,

[math]\frac{\Delta degree}{\Delta wire\ number}=\frac{5.09^{\circ}-4.79^{\circ} }{wire\ number}=\frac{.3^{\circ}}{wire\ number} [/math]

Similarly, finding the difference between wires 111 and 112,

[math]\frac{\Delta degree}{\Delta wire\ number}=\frac{40.82^{\circ}-40.51^{\circ}}{wire\ number}=\frac{.31^{\circ}}{wire\ number}[/math]


These differing values show that the bin width is not uniform in length, therefore a first order, linear fit, will not suffice.



Testing for a quadratic fit:

In[3]:= quad1=Fit[data1,{1,n,n^2},n]

Out[3]= 4.45564 +0.32015 n+0.0000417787 n^2

The quadratic fit does not work since it's first derivative

[math]\theta'\approx \Delta \theta=.325072-6.83308\ n[/math]

does not give the same spacing between low and high values of n as seen in the ced data. The coefficient near the first order will have to smaller than .31 to find a correlation that would agree.

Testing for a polynomial of degree 3 fit:

In[4]:= polynomial1=Fit[data1,{1,n,n^2,n^3},n]

Out[4]= 4.49876 +0.293001 n+0.000679074 n^2-3.57132*10^-6 n^3


This fit best matches the data found in ced

[math]\theta\equiv 4.49876 +0.293001 n+0.000679074 n^2-3.57132\times 10^{-6} n^3[/math]

As discussed earlier, taking the 1st derivative of this function will give us the spacing of the bins as a function of wire number.

[math]\theta '\equiv 0.293001 + 0.00135815 n - 0.000010714 n^2[/math]


The derivative of this function then will tell us where the bin spacing is at a minimum and a maximum.

[math]\theta ''\equiv .001021976-1.61514\times 10^{-5} n[/math]


[math]0.00135815 - 0.0000214279 n=0\Rightarrow Bin\ Spacing\ Maximum\ at\ n=63.3822[/math]

Comparing this maximum, we can see from Table 3 that near the maximum of 63 are seperated by larger distances than at n=1 or n=112. This is the midpoint of the plane as seen in the geometry file.

Binning based on wire numbers

The bin size based on wire number will need to be a uniform width of 1, as in an increment of 1 between the integer values of the wires. This uniformity in bin size based on wire numbers is not uniform when viewed by the angle theta due to the Drift Chamber geometry discussed earlier.

Modifying evioreader


Layer1bins.png
Layer1bins Isotropic.png
gStyle->SetStripDecimals(kTRUE);
TF1 *fit_function=new TF1("fit_function","[0]+[1]*x+[2]*x*x+[3]*x*x*x",4.49876,41.12592);
fit_function->SetParameters(4.49876,0.293001,0.000679074,-0.00000357132);
TGaxis *A1 = new TGaxis(0,5000,113,5000,"fit_function",510,"-");
A1->SetTitle("Angle Theta(degrees)");
A1->Draw();


Layer1binWeighted.pngMolThetaLabWeighted.png


Layer1binWeighted Isotropic.pngMolThetaLabWeighted2.png

Using the expression for n in terms of Theta:

[math]n = \frac{-957.412}{\tan{ \theta}+2.14437}+430.626[/math]


This relationship can be used to multiply each Moller Scattering angle theta in the lab frame, with it's differential cross-section weight, to find the Moller differential cross-section as a function of wire number in the lab frame.


MolThetaWireWeighted.pngMolThetaWireWeightedIsotropic.png


MolThetaWireWeightedAdjusted.pngMolThetaWireWeightedAdjustedIsotropic.png


TheoryDCbinsWire.pngTheoryDCbinsWireIsotropic.png

Moller Occupancy Rate

Comparing Rates

Using the values from Whitney:

Whitney values.png

For a 5cm target of LH2:

[math]\rho_{target}\times l_{target}=\frac{70.85 kg}{1 m^3}\times \frac{1 mole}{2.02 g} \times \frac{1000g}{1 kg} \times \frac{6.022\times10^{23} molecules\ LH_2}{1 mole} \frac{2 atoms}{1\ molecule\ LH_2} \times \frac{1m^3}{(100 cm)^3} \times \frac{5 cm}{ }=2.11\times 10^{23} \times \frac{10^{-24} cm^{2}}{barn}=2.11\times 10^{-1}\ barns^{-1}[/math]


Using the beam current of 100nA,

[math]\Phi_{beam}=\frac{100\times 10^{-9}\ A}{1} \times \frac{1\ C}{1\ A} \times \frac{1\ e^{-}}{1\ s} \times \frac{1}{1.602\times 10^{-19}C}\Rightarrow 6.2422\times 10^{11}\ \frac{1}{s}=\Phi_{e^{-}}[/math]


Given the beam Luminosity of:

[math]\mathcal {L}=\frac{1.32\times 10^{35}}{cm^2 \cdot s}\frac{10^{-24} cm^{2}}{barn}=\frac{1.32\times 10^{11}}{barn\cdot s}=\Phi_{beam}\ \rho\ l_{target}[/math]

We can check to make sure the density makes sense

[math]\Rightarrow \rho_{target}=\frac{1.32\times 10^{35}}{ \Phi_{beam}\ l_{target}cm^2 \cdot s}=\frac{1.32\times 10^{35}}{ 6.24\times 10^{11}\ \cdot 5cm^3}=\frac{4.23\times 10^{22}}{cm^3}[/math]


[math]\Rightarrow \rho_{target}=\frac{70.85 kg}{1 m^3}\times \frac{1 mole}{2.02 g} \times \frac{1000g}{1 kg} \times \frac{6.022\times10^{23} molecules\ LH_2}{1 mole} \times \frac{1m^3}{(100 cm)^3}\frac{2 atoms}{1\ molecule\ LH_2}=\frac{4.23\times 10^{22}}{cm^3}[/math]


Using the values from Whitney :


https://wiki.iac.isu.edu/index.php/CLAS12_RateEst_byWA

Rates
Energy 6 GeV 11 GeV
Process (nb) (nb)
Moller 22773001 75008636
DIS + radiative tail 128 83
Elastic e-p 5511220 3670740
Elastic radiative tail 24705 12944
π0 electro-production 14802 17908
π0 photo-production 569 852
π+ electro-production 4032 5536
π+ photo-production 282 487
π− electro-production 2806 3843
π− photo-production 199 342
Total 2.83317E7 7.87214E7



[math]R_{events}= \sigma_{events} \mathcal{L}=7.87\times 10^{-2}\ barn\ \cdot \frac{1.33\times 10^{11}}{barn\cdot s}=\frac{1.05\times 10^{10}events}{s}[/math]


[math]R_{Moller}= \sigma_{Moller} \mathcal{L}=7.50\times 10^{-2}\ barn\ \cdot \frac{1.33\times 10^{11}}{barn\cdot s}=\frac{9.97\times 10^{9}Moller}{s}[/math]


File:CLAS12ExpWS WA.pdf

Whitney 2.pngWhitney 3.png


Whitney 4.png


[math]\sigma=\frac{R}{\mathcal{L}}=\frac{dN}{dt}\cdot \frac{1}{\mathcal{L}}[/math]


[math]\Rightarrow \int\limits_{0}^{t}\, dt=\int\limits_{0}^{N}\frac{1}{\sigma \mathcal{L}}\, dN[/math]


[math]t_{simulated}=\frac{N_{events}}{\sigma_{events} \Phi \rho \ell}=\frac{1000000\ barn \cdot s}{7.87\times 10^{-2} \cdot 1.33\times 10^{11}\ barn}=9.54\times 10^{-5} s[/math]



[math]N_0=\Delta t \cdot R_{events}=\Delta t \cdot \frac{N_{events}}{t_{simulated}}=500\times 10^{-9}\ s \cdot \frac{1\times 10^6}{0.0954\times 10^{-3}\ s}=5240[/math]


[math]Occupancy=\frac{N_{hits}}{N_0}=\frac{N_{hits}}{\Delta t \cdot R_{events}}=\frac{t_{simulated}\cdot N_{hits}}{N_{events}\cdot \Delta t}=[/math]

Similarly,


[math]N_{events} =R_{events}\cdot t_{simulated}=\frac{1.05\times 10^{10}events}{s} \cdot 9.54\times 10^{-5} s=1001700\ events[/math]


[math]N_{Moller} =R_{Moller}\cdot t_{simulated}=\frac{9.97\times 10^{9}Moller}{s} \cdot 9.54\times 10^{-5} s=951138\ Moller[/math]


[math]\sigma=\frac{N_{events}}{N_{incident}}\frac{1}{\rho \ell}\Rightarrow N_{incident}=\frac{N_{events}}{\sigma \rho \ell}=\frac{951138}{.075\cdot 2.11\times 10^{-1}}=6\times 10^7\ incident [/math]


[math]\left ( \frac{Number\ of\ hits}{Moller\ electron}\right ) \left (\frac{Moller\ electrons}{incidents\ electron} \right) \left (\frac{incident\ electrons}{sec} \right )[/math]

GEANT Simulations

https://wiki.iac.isu.edu/index.php/Converting_to_barns

https://wiki.iac.isu.edu/index.php/Check_Differential_Cross-Section

Converting the number of electrons scattered per angle theta to barns, we can use the relation

[math]\mathcal{L}=\frac{R_{scattered}}{\sigma} = \Phi_{beam}\ \rho\ \ell [/math]


[math]\sigma=\frac{R_{scattered}}{\mathcal{L}} =\frac{R_{scattered}}{\Phi_{beam}\ \rho\ \ell}= \frac{R_{scattered}}{R_{incident}\ \rho\ \ell}=\frac{N_{scattered}}{\Delta t}\cdot \frac{\Delta t}{N_{incident}}\cdot \frac{1}{\rho \ell}[/math]

If the time is taken to be the same for the amount scattered as for the amount incident (the time simulated), this can be viewed as the probability of one incident electron producing a Moller event.


[math]\sigma=\frac{N_{scattered}}{N_{incident}}\frac{1}{\rho \ell}[/math]


While this expression has no explicit dependancies on energy, the ratio is a function of the energy, as well as the physical makeup of the target.

This gives, for LH2:

[math]\rho_{target}\times l_{target}=\frac{70.85 kg}{1 m^3}\times \frac{1 mole}{2.02 g} \times \frac{1000g}{1 kg} \times \frac{6\times10^{23} molecule}{1 mole} \times \frac{2\ atoms}{molecule}\times \frac{1m^3}{(100 cm)^3} \times \frac{1 cm}{ } \times \frac{10^{-24} cm^{2}}{barn} =4.2\times 10^{-2} barns^{-1}[/math]


From earlier simulations for random angle Phi, we know that the full range of Theta is limited depending on the target material.


MollerThetaLab 4e7 LH2 11GeV.pngMollerThetaLab 4e7 NH3 11GeV.png


MollerThetaLab 4e7 LH2 11GeV Detector.pngMollerThetaLab 4e7 NH3 11GeV Detector.png


[math]\sigma = \frac{N_{events}}{N_{incident}\ \rho\ \ell}=\frac{975593}{40000000\ \cdot 4.2\times 10^{-2} barns^{-1}}=\frac{0.024}{4.2\times 10^{-2} barns^{-1}}=0.58 barns[/math]


[math]\sigma=\frac{R_{events}}{\mathcal{L}} \Rightarrow \mathcal{L}=\frac{R_{events}}{\sigma}[/math]


[math]\mathcal{L}=\frac{dN_{events}}{dt}\frac{1}{ \sigma}\Rightarrow \int_{0}^{t_{simulated}}\mathcal {L}\, dt= \int_{0}^{N_{events}}\frac{1}{\sigma}\, dN[/math]


[math]\mathcal{L} \cdot t_{simulated}=\frac{N_{events}}{\sigma}[/math]


For a Luminosity of [math]\mathcal{L}=\frac{1.3\times 10^{11}}{barn\cdot s}[/math]


[math]\frac{1.3\times 10^{11}}{barn\cdot s} \cdot t_{simulated}=\frac{975593}{.58\ barn}[/math]


[math]t=1.3\times 10^{-5}\ s[/math]


Comparison of GEANT Simulation to Whitney Data

Rates
Simulation GEANT4 Whitney
Event Cross-Section (nb) .61 0.079
Moller Cross-Section (nb) 0.58 0.075
Length of Target (cm) 1 5
t_{simulated} (s) 1.3E-5 9.54E-5
N_{events} 1026940 1001700
N_{Moller} 975593 951138
N_{incident} 4E7 6E7


Moller events occur for about 2.5% of the incident electrons on a LH2 target. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material

Isotropic Weighted Distribution

Isotropic in CM

Assuming a 1cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,

TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
Combo->Add(Layer1binsWeighted,23.8);
Combo->Draw();
Layer1binsMollerRate.png


[math]\frac{2003912\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=6.68\times 10^6\ Moller\ electrons[/math]


[math]\frac{6.68\times 10^6\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=3.34\times 10^8\ Incident\ electrons[/math]


[math]\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{4.2\times 10^{-2}}=.48\ barn[/math]


[math]\mathcal{L}=N_{incident}\ \rho \ell=3.34\times 10^8\ Incident\ electrons \cdot 4.2\times 10^{-2}=\frac{1.40\times 10^{7}\ electrons}{barn \cdot s}[/math]


Assuming a 5cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,

TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
Combo->Add(Layer1binsWeighted,4.76);
Combo->Draw();
Layer1binsMollerRate 2.png


[math]\frac{400782\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=1.34\times 10^6\ Moller\ electrons[/math]


[math]\frac{1.34\times 10^6\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=6.67\times 10^7\ Incident\ electrons[/math]


[math]\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{2.1\times 10^{-1}}=.095\ barn[/math]


[math]\mathcal{L}=N_{incident}\ \rho \ell=6.67\times 10^7\ Incident\ electrons \cdot 2.1\times 10^{-1}=\frac{1.40\times 10^{7}\ electrons}{barn \cdot s}[/math]

Isotropic in Lab

Assuming a 1cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,

TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
Combo->Add(Layer1binsWeighted,23.8);
Combo->Draw();
Layer1binsMollerRateIsotropic.png


[math]\frac{833000\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=2.78\times 10^6\ Moller\ electrons[/math]


[math]\frac{2.78\times 10^6\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=1.39\times 10^8\ Incident\ electrons[/math]


[math]\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{4.2\times 10^{-2}}=.48\ barn[/math]


[math]\mathcal{L}=N_{incident}\ \rho \ell=3.34\times 10^8\ Incident\ electrons \cdot 4.2\times 10^{-2}=\frac{5.83\times 10^{6}\ electrons}{barn \cdot s}[/math]


Assuming a 5cm long target of LH2 where around 2% of the incident electrons will result in a Moller electron,

TH1F *Combo=new TH1F("Layer1binsMollerRate","Layer1binsMollerRate",113,0,113);
Combo->Add(Layer1binsWeighted,4.76);
Combo->Draw();
Layer1binsMollerRate 2Isotropic.png


[math]\frac{166600\ Moller\ Events\ in\ Range}{.30\ Moller\ Events\ in\ Range\ per\ Moller\ Electron}=5.55\times 10^5\ Moller\ electrons[/math]


[math]\frac{5.55\times 10^5\ Moller\ electrons}{.02\ Moller\ Events\ \ per\ Incident\ Electron}=2.78\times 10^7\ Incident\ electrons[/math]


[math]\sigma=\frac{N_{Moller}}{N_{incident}\cdot \rho \ell}=\frac{.02\ barn}{2.1\times 10^{-1}}=.095\ barn[/math]


[math]\mathcal{L}=N_{incident}\ \rho \ell=6.67\times 10^7\ Incident\ electrons \cdot 2.1\times 10^{-1}=\frac{5.83\times 10^{6}\ electrons}{barn \cdot s}[/math]

back