Difference between revisions of "Dc:Integrated Digitized Bank"
(→Wire) |
|||
(11 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
DC system will measure the momentum | DC system will measure the momentum | ||
of charged particles emerging from the target. | of charged particles emerging from the target. | ||
− | + | <center> | |
− | {| border=1 | + | {| border=1|center| |
|+ DC Integrated Digitized Bank Contents | |+ DC Integrated Digitized Bank Contents | ||
|- | |- | ||
Line 10: | Line 10: | ||
|- | |- | ||
| 1 | | 1 | ||
− | | | + | | [[Dc:Integrated_Digitized_Bank#Sector|Sector]] |
|- | |- | ||
| 2 | | 2 | ||
− | | | + | | [[Dc:Integrated_Digitized_Bank#Superlayer|Superlayer]] |
|- | |- | ||
| 3 | | 3 | ||
− | | | + | | [[Dc:Integrated_Digitized_Bank#Layer|Layer]] |
|- | |- | ||
| 4 | | 4 | ||
− | | | + | | [[Dc:Integrated_Digitized_Bank#Wire|Wire]] |
|- | |- | ||
| 5 | | 5 | ||
− | | LR | + | | [[Dc:Integrated_Digitized_Bank#LR|LR]] |
|- | |- | ||
| 6 | | 6 | ||
− | | doca | + | | [[Dc:Integrated_Digitized_Bank#doca|doca]] |
|- | |- | ||
| 7 | | 7 | ||
− | | sdoca | + | | [[Dc:Integrated_Digitized_Bank#sdoca|sdoca]] |
|- | |- | ||
| 8 | | 8 | ||
− | | time | + | | [[Dc:Integrated_Digitized_Bank#Time|time]] |
|- | |- | ||
| 9 | | 9 | ||
− | | stime | + | | [[Dc:Integrated_Digitized_Bank#stime|stime]] |
|- | |- | ||
| 99 | | 99 | ||
− | | hitn | + | | [[Dc:Integrated_Digitized_Bank#Hit Number|hitn]] |
|} | |} | ||
+ | |||
+ | </center> | ||
==Sector== | ==Sector== | ||
− | Viewing the Drift Chambers | + | Viewing the Drift Chambers parallel to the beam line, in the x-y plane, the sector numbering runs 1-6 counter-clockwise starting at phi=0 degrees. Each sector is 60 degrees wide in phi, with sector 1 falling within the range -30 to +30 degrees in phi. |
<center>[[File:DC_Sectors.png]]</center> | <center>[[File:DC_Sectors.png]]</center> | ||
==Superlayer== | ==Superlayer== | ||
+ | The drift chambers are divided into 3 diferent regions at around 2 meters for region 1, 3 meters for region 2, and 4 meters for region 3. Within each region, there are two superlayers, which are numbered sequential starting with 1 as the nearest to the target. | ||
<center>[[File:Sectors1&4.png]]</center> | <center>[[File:Sectors1&4.png]]</center> | ||
==Layer== | ==Layer== | ||
+ | |||
+ | Each Superlayer is composed of 6 layers, numbered sequentially starting from nearest to furthest to the target. | ||
+ | |||
<center>[[File:Layers_SuperLayers1&4.png]]</center> | <center>[[File:Layers_SuperLayers1&4.png]]</center> | ||
==Wire== | ==Wire== | ||
+ | Each layer has 112 wires, numbered sequentially from 1 to 112 | ||
+ | |||
+ | <center>[[File:DC_wires.png]]</center> | ||
==LR== | ==LR== | ||
Line 64: | Line 73: | ||
==Hit Number== | ==Hit Number== | ||
+ | |||
+ | =Links= | ||
+ | [[Verfication_of_Mother/Daughter_Occupancy|Back]] |
Latest revision as of 20:28, 25 July 2016
DC: Integrated Digitized Bank Contents
DC system will measure the momentum of charged particles emerging from the target.
SubBank Number | Variable |
---|---|
1 | Sector |
2 | Superlayer |
3 | Layer |
4 | Wire |
5 | LR |
6 | doca |
7 | sdoca |
8 | time |
9 | stime |
99 | hitn |
Sector
Viewing the Drift Chambers parallel to the beam line, in the x-y plane, the sector numbering runs 1-6 counter-clockwise starting at phi=0 degrees. Each sector is 60 degrees wide in phi, with sector 1 falling within the range -30 to +30 degrees in phi.
Superlayer
The drift chambers are divided into 3 diferent regions at around 2 meters for region 1, 3 meters for region 2, and 4 meters for region 3. Within each region, there are two superlayers, which are numbered sequential starting with 1 as the nearest to the target.
Layer
Each Superlayer is composed of 6 layers, numbered sequentially starting from nearest to furthest to the target.
Wire
Each layer has 112 wires, numbered sequentially from 1 to 112