Difference between revisions of "2-LTD-brick x-pinch driver notes"
Jump to navigation
Jump to search
Line 11: | Line 11: | ||
=10/30/14 Spielman about calibration error= | =10/30/14 Spielman about calibration error= | ||
− | + | *error in my Rogowski calibration (proposal, short12, 082914) is 1.3% just because of scope digitization | |
− | + | *we need to reduce this error with multiple shorts: do 10 shots => error ~1/sqrt(10) |
Revision as of 20:57, 30 October 2014
Minimum operating current
- There is a minimum operating current due to need to work in the magnetic self-isolating regime [L. E. Aranchuk, A. S. Chuvatin, and J. Larour, Rev. Sci. Instrum. 75, 69 (2004)]
- For our geometry (6 mm gam, 2.5" anode and 2" cathode) and taking min voltage 60 kV, the minimum operating current will be
10/30/14 Spielman about calibration error
- error in my Rogowski calibration (proposal, short12, 082914) is 1.3% just because of scope digitization
- we need to reduce this error with multiple shorts: do 10 shots => error ~1/sqrt(10)