− | The figure also shows Garfield simulation for an electron's primary ionization, it is noticed that GENAT4.9.6 results meets with those of Garfield when the minimum incident electron energy is <math> 2x10^4</math> eV. Such an energy is much lower than the threshold kinetic energy which an electron needs to make an ionization in the detector's drift region (the threshold kinetic energy for an electron is more than 2 MeV). | + | The figure also shows Garfield simulation for an electron's primary ionization, it is noticed that GENAT4.9.6 results meets with those of Garfield when the minimum incident electron energy is <math> 2x10^4</math> eV. Such an energy is much lower than the threshold kinetic energy which an electron needs to make an ionization in the detector's drift region (the threshold kinetic energy for an electron is more than 2 MeV 5cm away from the detector's window). |
Revision as of 15:02, 3 March 2014
Energy threshold for electron and gamma entering detector
Detemine the energy threshold that an electron and a photon need to surpass in order to pass through the kapton, gas, the copper cathode, and the FR4.
Draw a picture with dimensions of all the layers
Energy -vs- counts per incident particle
Alpha Particles ionization simulation using GEANT4
GEANT4 simulates the ionization of alpha particles in Ar/CO2 90/10 gas. Geant4 can simulate the ionization process for alpha particles. Unfortunately the value of the step function underestimates the number of delta electrons even after decreasing the step cut to 1 nm. Also,using GEANT4 overestimates the range of alpha particles in Ar/CO2 gas when compared to those that srim calculates File:Alpha range ArCo2.txt, the following table shows the maximum range of alpha particles that are emitted from the U-233, and the ranges calculated by srim.
Alpha Energy (MeV) | G4 Range (cm) | Srim Range (um) |
1.0 | 0.56599 | 129.49 |
2.0 | 1.1467 | 255.91 |
3.0 | 1.9024 | 417.27 |
4.0 | 2.8012 | 612.45 |
5.0 | 3.8425 | 839.91 |
Based on the previous table, GEANT4 failed to calculate the expected alpha range for most alpha energies, and underestimated the number of alpha's delta electrons emitted through that range, but it is still useful tool to simulate the primary delta electrons when negative beta particles pass through a defined medium.
Calculating the number of the delta electrons without using GEANT4
There is another way to calculate the number of delta electrons without using GEANT4. It starts by calculating the average energy loss
by the alpha particles and the average energy loss per unit length in Ar/CO2 gas using the Bethe-Block equation. It then uses the the following equation:
to calculate the actual energy loss by ionization
, where represents random landau number.By dividing the energy loss by the minimum energy for producing a pair of ion/electron pair W, this equation yields the number of electrons emitted by ionization.
Srim can simulate the motion of an alpha particle in Ar/CO2 gas by allowing for the change in the stopping power per unit length. It can also show the ionization energy loss as shown in the following figure:
This figure shows the ionization energy loss of 999 alpha particles as they pass through Ar/CO2 gas. Integrating the area under the curve and dividing by (W*1000) will estimate the number of delta electrons produced by an alpha particle.
Bethe block formula calculates the average ionization energy loss as the following:
for an electron of rest mass
,Number of Primary ionization events per cm
from beta particle as a function of beta particle energy using Garfield and GEANT4
GEANT4 can simulate the primary number of delta electrons for a negative beta particle penetrating ArCO2. Using TestEm10 example and choosing appropriate default cut, GEANT4 counts the same number of primary delta electrons for a 1.1 MeV negative beta particles, and determines the energy of the delta electrons energy and momentum depending on Moller or Bhabha's scattering depending on the value of the kinetic energy cut used.<ref name = "Urban">Urbán, L. (1998, 10 09). Geant4 physics reference manual. Retrieved from http: //geant4.web.cern.ch/geant4/G4UsersDocuments/UsersGuides/PhysicsReferenceManual/html/node41.html </ref>
The following figure shows the number of the primary electrons that are emitted from negative beta with energy E, passing through a 90/10 Ar/CO2 gas:
Overlay with dE/dx formula and fill in gaps
something is wrong with G4 result for electron energies below 1 keV.
from photon as a function of photon particle energy using Garfield and GEANT4
Detector Geometry in GEANT4
Charge particles and photons primary ionization
The physical interactions that take place inside the detector is simulated by GEANT4.9.6 to estimation the primary charge collected by the drift electric in GEM detector. GEM detector depends mainly on the particles interaction with Ar/CO2 atoms and molecules, especially the ones that directly (or indirectly) produce free charge that can be collected by the drift electric field. Specifically for the GEM detector described in section XX, the detector signal can be produced by gamma rays, electrons, or neutrons. GEANT4.9.6 has been used to estimate the primary charge caused by those particles in case of electrons and neutrons, but for photons, GENAT4 is used to produce the photoionization energy spectrum for Ar/CO2 gas.
The simulation started by determining the number of primary electrons produced by charged particles in Ar/CO2. The number of the primary electrons depends on the particle's charge and mass and kinetic energy. As a result alpha particles have the highest number of primary electrons, electrons, then photons which can only produce an electron per photon assuming the the photoabsorption is dominant process in Ar/CO2 gas.
By modifying EmTest10 example in GEANT4.9.6, the number of primary electrons produced by an electron travels 1 cm is shown in the figure below.
The figure also shows Garfield simulation for an electron's primary ionization, it is noticed that GENAT4.9.6 results meets with those of Garfield when the minimum incident electron energy is
eV. Such an energy is much lower than the threshold kinetic energy which an electron needs to make an ionization in the detector's drift region (the threshold kinetic energy for an electron is more than 2 MeV 5cm away from the detector's window).
<References/>