Difference between revisions of "Au-196 Foil-08-22-13"

From New IAC Wiki
Jump to navigation Jump to search
Line 22: Line 22:
 
|  Run Number || Date (Seconds since 1970)|| Sec since irradiation|| Running Time (sec) || 333.02 Rate || 355.73 rate ||Calibration Desc
 
|  Run Number || Date (Seconds since 1970)|| Sec since irradiation|| Running Time (sec) || 333.02 Rate || 355.73 rate ||Calibration Desc
 
|-
 
|-
|5838 || August 26, 2013 11:34:58 AM MDT (1377538498)|| 337337|| 477 || ||   || OR, Au Foil 130100-009, only counting with detector 180-3 (no TDC) 8 min 1sec long, 808 Hz, Det B HV OFF, ntuple->Draw("-25.6847+ADC5*0.359504>>(4096,0,4096)")
+
|5838 || August 26, 2013 11:34:58 AM MDT (1377538498)|| 337337|| 477 || 22 +/- 4 || 73 +/- 13 || OR, Au Foil 130100-009, only counting with detector 180-3 (no TDC) 8 min 1sec long, 808 Hz, Det B HV OFF, ntuple->Draw("-25.6847+ADC5*0.359504>>(4096,0,4096)")
 
|-
 
|-
 
|5852 ||August 27, 2013 4:24:43 PM MDT(1377642283)  ||441122 || 512 || 17 +/- 3 || 58 +/- 8  || Gold Foil 130100-009, only counting with detector 180-3 (no TDC)  7 min 34 sec long,  716 Hz, Det B HV ''' OFF''', ntuple->Draw("-25.6847+ADC5*0.359504>>(4096,0,4096)")
 
|5852 ||August 27, 2013 4:24:43 PM MDT(1377642283)  ||441122 || 512 || 17 +/- 3 || 58 +/- 8  || Gold Foil 130100-009, only counting with detector 180-3 (no TDC)  7 min 34 sec long,  716 Hz, Det B HV ''' OFF''', ntuple->Draw("-25.6847+ADC5*0.359504>>(4096,0,4096)")

Revision as of 19:16, 6 November 2013

Gold irradiation physics

Knock a neutron out of natural gold such that an excited state of Au-196 remains that will undergo electron capture to Pt-196 with a half life of 6 days or 2% of the time it can be left in a meta stable state with two possible half lifes of 8 seconds or 9 hours.

[math]{197 \atop\; }Au (\gamma,n){196 \atop \; }Au[/math]

The 8 sec metastable state of Au-196 decays through the emission of only one 84.66 keV photon.

The 9.6 hour metastable state has high intensity gamma lines at 147.81 keV and 188.27 keV. The 147.81 and the 188.27 are in coincidence.

[math]{196 \atop \; }Au \rightarrow {196 \atop \; }Pt^* [/math] with a half life of 6 days.

The Pt-196 has a 355.73 dominant (100% relative intensity) gamma line that goes to the 256.2 state giving off a 97.3 keV photon

Irradiation of foil 130100-009

Irradiation finished at August 22, 2013 1:52:41 PM MDT(unix seconds = 1377201161)

The 6.1 day half life isotope emits a 333.02 and a 355.73 keV in coincidence.

Run Number Date (Seconds since 1970) Sec since irradiation Running Time (sec) 333.02 Rate 355.73 rate Calibration Desc
5838 August 26, 2013 11:34:58 AM MDT (1377538498) 337337 477 22 +/- 4 73 +/- 13 OR, Au Foil 130100-009, only counting with detector 180-3 (no TDC) 8 min 1sec long, 808 Hz, Det B HV OFF, ntuple->Draw("-25.6847+ADC5*0.359504>>(4096,0,4096)")
5852 August 27, 2013 4:24:43 PM MDT(1377642283) 441122 512 17 +/- 3 58 +/- 8 Gold Foil 130100-009, only counting with detector 180-3 (no TDC) 7 min 34 sec long, 716 Hz, Det B HV OFF, ntuple->Draw("-25.6847+ADC5*0.359504>>(4096,0,4096)")

PAA_8-22-13#Gold_Foil