Difference between revisions of "IAC-QDC Measurements"

From New IAC Wiki
Jump to navigation Jump to search
Line 10: Line 10:
 
|6075 || 12:39:16 || 13:19:33 || shutter open
 
|6075 || 12:39:16 || 13:19:33 || shutter open
 
|-
 
|-
|6077 || 13:34 :37 ||   || shutter close, pmt is connected to ch#11 qdc and ch#27 tdc  
+
|6077 || 13:34 :37 || 14:19:05  || shutter close, pmt is connected to ch#11 qdc and ch#27 tdc  
 
|}
 
|}

Revision as of 20:16, 18 September 2013

09/18/13

Detector voltage is 2.8, 3.4 kV for cathode and GEM. filter Amp. (x4 level 6) is used for amplify the GEM's output, ch#5 is used as an ADC input and ch# 31 in TDC


Run Number Start time End time Notes
6075 12:39:16 13:19:33 shutter open
6077 13:34 :37 14:19:05 shutter close, pmt is connected to ch#11 qdc and ch#27 tdc