Line 5: Line 5:
 
| 06/25/13 || 15:05 ||  30 || 40 ||  -50 || 0.0 || 0.025 || Guard current is at 15.9 microamps. Have never observed it above 0.000 before. Turned off voltage to check cabling setup.
 
| 06/25/13 || 15:05 ||  30 || 40 ||  -50 || 0.0 || 0.025 || Guard current is at 15.9 microamps. Have never observed it above 0.000 before. Turned off voltage to check cabling setup.
 
|-
 
|-
| 06/25/13 || 15:19 ||  30 || 40 ||  -50 || 0.0 || 0.025 || Found a grounding strap attached to the HVB side of Board 1. Removed and torqued down the screw it was on. Guard current is normal now.
+
| 06/25/13 || 15:19 ||  30 || 40 ||  -50 || 0.0 || 0.025 || Found a grounding strap attached to the HVB side of Board 1. Removed and torqued down the screw it was on. Guard current is normal now. Field/sense current stabilized within 30 seconds to this reading.
 +
|-
 +
| 06/25/13 || 15:22 ||  536 || 1500 ||  -750 || 4.6 || 4.7 || Current appears stable +/- 0.2 microamps for at least 30 seconds after finishing voltage rise.

Revision as of 21:29, 25 June 2013

Date Time (24h) Guard (V) Sense (V) Field (V) Sense ([math]\mu[/math]A) Field ([math]\mu[/math]A) comments
06/25/13 15:05 30 40 -50 0.0 0.025 Guard current is at 15.9 microamps. Have never observed it above 0.000 before. Turned off voltage to check cabling setup.
06/25/13 15:19 30 40 -50 0.0 0.025 Found a grounding strap attached to the HVB side of Board 1. Removed and torqued down the screw it was on. Guard current is normal now. Field/sense current stabilized within 30 seconds to this reading.
06/25/13 15:22 536 1500 -750 4.6 4.7 Current appears stable +/- 0.2 microamps for at least 30 seconds after finishing voltage rise.