*N.Ratakhin et al. "Compact pulse power generator for X-pinch researches" 28th ICPIG, July 15-20, 2007, Prague, Czech Republi [http://icpig2007.ipp.cas.cz/files/download/cd-cko/ICPIG2007/pdf/3P15-14.pdf] | *N.Ratakhin et al. "Compact pulse power generator for X-pinch researches" 28th ICPIG, July 15-20, 2007, Prague, Czech Republi [http://icpig2007.ipp.cas.cz/files/download/cd-cko/ICPIG2007/pdf/3P15-14.pdf] | ||
**"The main requirements imposed on the generator are the current amplitude 150-300 kA and the rate of the current rise 1-2 kA/ns. At the moment, these parameters of the current pulse can be provided only by enough large fixed-site generators weighing from 300 kg to several tons. These shortcomings limit to a great extent the feasibility of this diagnostic technique in studies of extreme states. Therefore, the design of a portable pulse generator which provides the required parameters makes it possible to proceed to a new level of diagnostics of fast processes." | **"The main requirements imposed on the generator are the current amplitude 150-300 kA and the rate of the current rise 1-2 kA/ns. At the moment, these parameters of the current pulse can be provided only by enough large fixed-site generators weighing from 300 kg to several tons. These shortcomings limit to a great extent the feasibility of this diagnostic technique in studies of extreme states. Therefore, the design of a portable pulse generator which provides the required parameters makes it possible to proceed to a new level of diagnostics of fast processes." | ||
+ | |||
+ | |||
+ | ==Design's Possibilities== | ||
+ | |||
+ | ===PRS based on transformation of ISIS Induction Cell Driver=== | ||
+ | |||
+ | ===PRS based on building separate Marx Generator=== | ||
+ | |||
+ | ===PRS based on building separate Marx Generator + Pulse Forming Line=== | ||
+ | |||
+ | ===PRS based on Linear Transformer Driver (LTD) technologies=== | ||
+ | |||
+ | This design needs the massive ferromagnetive core and uses wireless induction technology to drive the current. This approach | ||
+ | is good for design of large compact facilities, like Induction Accelerator or Z-Machine. We can uses the idea of LRC circuit without inductive voltage adder |
Revision as of 15:43, 7 February 2013
The needs in Compact Pulsed Power X-Pinch Generators
- N.Ratakhin et al. "Compact pulse power generator for X-pinch researches" 28th ICPIG, July 15-20, 2007, Prague, Czech Republi [1]
- "The main requirements imposed on the generator are the current amplitude 150-300 kA and the rate of the current rise 1-2 kA/ns. At the moment, these parameters of the current pulse can be provided only by enough large fixed-site generators weighing from 300 kg to several tons. These shortcomings limit to a great extent the feasibility of this diagnostic technique in studies of extreme states. Therefore, the design of a portable pulse generator which provides the required parameters makes it possible to proceed to a new level of diagnostics of fast processes."
Design's Possibilities
PRS based on transformation of ISIS Induction Cell Driver
PRS based on building separate Marx Generator
PRS based on building separate Marx Generator + Pulse Forming Line
PRS based on Linear Transformer Driver (LTD) technologies
This design needs the massive ferromagnetive core and uses wireless induction technology to drive the current. This approach
is good for design of large compact facilities, like Induction Accelerator or Z-Machine. We can uses the idea of LRC circuit without inductive voltage adder