Difference between revisions of "Sadiq Thesis"

From New IAC Wiki
Jump to navigation Jump to search
Line 292: Line 292:
 
{| border="1"  |cellpadding="20" cellspacing="0  
 
{| border="1"  |cellpadding="20" cellspacing="0  
 
|-
 
|-
|  run#  || ||Attenuation (dB)|| ADC2
+
|  run#  || <math>R = \frac{N_{e^+}}{N_{e^-}} </math>
 
|-
 
|-
| 3735  ||  ||27.5 || 3009
+
| 3735  ||  <math>(8.7 \pm 1.4)\times 10^{-15}</math>
 
|-
 
|-
| 3736  ||  || 27.5 || 2935
+
| 3736  ||  <math>(1.46 \pm 0.76)\times 10^{-16}</math>
 
|-
 
|-
| 3737  ||  || 27.5 || 3018
+
| 3737  ||  <math>(8.1 \pm 1.3)\times 10^{-15}</math>
 
|}
 
|}
  

Revision as of 00:47, 8 October 2012

Introduction

Positron

Positron is the antimatter of electron. Positrons have same mass as electron ( [math]511~\frac{keV}{c^2}[/math]), carries positive charge, and it is noted as "[math]e^+[/math]".

Positrons predicted by Paul Dirac in 1928, <ref name="Dirac1928"> The Quantum Theory of the Electron, P. A. M. Dirac, Proc. R. Soc. Lond. A February 1, 1928 117 778 610-624;</ref>, and experimentally observed by Dmitri Skobeltsyn in 1929 and by Carl D. Anderson in 1932 <ref name="e+_discover"> General Chemistry, Taylor and Francis. p. 660. </ref>. Anderson also coined the term positron and he won the Nobel Prize for Physics in 1936.



<ref name="name"> BOOK_Gernal, Auther, Month_Year,issue,page </ref>

Positron Beamline History

Theory

positron creation from Bremsstrahlung

Positron rate prediction

Apparatus

HRRL Positron Beamline

HRRL beamline layout is given in the figure below, and the item descriptions are given in the table below.

HRRL beamline layout.



Item Description
T1 Positron target
T2 Annihilation target
EnS Energy Slit
FC1, FC2 Faraday Cups
Q1,...Q10 Quadrupoles
D1, D2 Dipoles
NaI NaI Detecotrs
OTR Optical Transition Radiaiton screen
YAG Yttrium Aluminium Garnet screen

Som parameters of HRRL is given by:

Parameter Unit Value
maximum energy MeV 16
peak current mA 100
repetition rate Hz 300
absolute energy spread MeV 2-4
macro pulse length ns >50


Beam properties

Emittance Measurement

Emittance is an important parameter in accelerator physics. If emittance with twiss parameters are given at the exit of the gun, we will be able to calculate beam size and divergence any point after the exit of the gun. Knowing the beam size and beam divergence on the positron target will greatly help us study the process of creating positron. Emittance with twiss parameters are also key parameters for any accelerator simulations. Also, energy and energy spread of the beam will be measured in the emittance measurement.

What is Emittance

Fig.1 Phase space ellipse <ref name="MConte08"></ref>.

In accelerator physics, Cartesian coordinate system was used to describe motion of the accelerated particles. Usually the z-axis of Cartesian coordinate system is set to be along the electron beam line as longitudinal beam direction. X-axis is set to be horizontal and perpendicular to the longitudinal direction, as one of the transverse beam direction. Y-axis is set to be vertical and perpendicular to the longitudinal direction, as another transverse beam direction.

For the convenience of representation, we use [math]z[/math] to represent our transverse coordinates, while discussing emittance. And we would like to express longitudinal beam direction with [math]s[/math]. Our transverse beam profile changes along the beam line, it makes [math]z[/math] is function of [math]s[/math], [math]z~(s)[/math]. The angle of a accelerated charge regarding the designed orbit can be defined as:

[math]z'=\frac{dz}{ds}[/math]

If we plot [math]z[/math] vs. [math]z'[/math], we will get an ellipse. The area of the ellipse is an invariant, which is called Courant-Snyder invariant. The transverse emittance [math]\epsilon[/math] of the beam is defined to be the area of the ellipse, which contains 90% of the particles <ref name="MConte08"> M. Conte and W. W. MacKay, “An Introduction To The Physics Of Particle Accelera tors”, World Scientifc, Singapore, 2008, 2nd Edition, pp. 257-330. </ref>.

By changing quadrupole magnetic field strength [math]k[/math], we can change beam sizes [math]\sigma_{x,y}[/math] on the screen. We make projection to the x, y axes, then fit them with Gaussian fittings to extract rms beam sizes, then plot vs [math]\sigma_{x,y}[/math] vs [math]k_{1}L[/math]. By Fitting a parabola we can find constants [math]A[/math],[math]B[/math], and [math]C[/math], and get emittances.

Emittance Measurements with an OTR

A beam emittance measurement of the HRRL was performed at Idaho State University's IAC with YAG (Yttrium Aluminium Garnet) was performed. Due to the high sensitivity of YAG, the beam image was saturated and beam spot pears rather big. Comparison study shows that for same beam YAG screen shows bigger beam size than Optical Transition Radiation (OTR) screen. An OTR based viewer was installed to allow measurements at the high electron currents available using the HRRL.

The OTR screen is 10 [math]\mu m[/math] thick aluminium. Beam images were taken with digital CCD camera, a MATLAB tool were used to extract beamsize and emittance.

The visible light from the OTR based viewer is produced when a relativistic electron beam crosses the boundary of two mediums with different dielectric constants. Visible radiation is emitted at an angle of 90 degree with respect to the incident beam direction<ref name="OTR"> Tech. Rep., B. Gitter, Los Angeles, USA (1992). </ref> when the electron beam intersects the OTR target at a 45 degree angle. These backward-emitted photons are observed using a digital camera and can be used to measure the shape and intensity of the electron beam based on the OTR distribution.


Quadrupole Scanning Method
Fig. Simplified setup configuration for HRRL beamline at 2011 March measurement.

Figure on the right illustrates the apparatus used to measure the emittance using the quadrupole scanning method. A quadrupole is positioned at the exit of the linac to focus/de-focus the beam as observed on a downstream view screen. The 3.1~m distance between the quadrupole and the screen was chosen in order to minimize chromatic effects and to satisfy the thin lens approximation.

Experimental setup is shown in the following figure

I chose one of the quad at a time to do the scan and turned off all the other quads. Optical transition radiation was observed at OTR target. At the end of 0 degree beamline I had a Faraday cup to measure the charge of the beam. Camera cage system was located below the OTR target. There are 3 lenses used to focus lights from target to the CCD camera. Target can be pushed into or taken out of the beamline by the actuator at the top.

OTR Target can be pushed into or taken out of the beamline vertically by the actuator at the top, which is attached to the 6-way cross. This actuator controlled remotely at the control desk.

Camera cage system was located below the OTR target. Cage system attached to the bottom of the 6-way cross. Lower end of cross is a transparent window. There are 3 lenses used to focus lights from target to the CCD camera. They have focal length of 100 mm, 500 mm, and 50 mm.

The lens closest to the OTR target is 10 cm away from the target, an it has 100 mm focal length. This lens was located as close to the target as possible, so that we might collect as much OTR light as possible, and it was thus called collector lens. The lens in the middle has focal length of 500 mm. Moving this lens will change total focal length in a small amount, and this allow us to do fine tuning. Thus, we called this lens fine tuning lens. The last lens, which is furthest from target, and closed to the CCD camera has the shortest focal length of 5o mm. Its short focal length allow us to focus the light on the very small sensing area of the CCD camera.

Fig. HRRL beamline: Optical lenses lay out for optical cage system.
Experiment with OTR

Optical Transition Radiation (OTR): Transition radiation is emitted when a charge moving at a constant velocity cross a boundary between two materials with different dielectric constant.

When relativistic electron beam pass through Aluminum target OTR is produced. OTR are taken for different quadrupole coil currents.

Fig. OTR image of 0 Amp Q1 coil current.
Fig. OTR image of +1 Amp Q1 coil current.
Fig. OTR image of +2 Amp Q1 coil current.
Data Analysis and Results

The projection of the beam is not Gaussian distribution. So, I fit Super Gaussian fitting <ref name="BeamDisBeyondRMS"> F.-J Decker, “Beam Distributions Beyond RMS”, BIW94, Vancouver,CA,Sep 1994, . </ref>.

I used the MATLAB to analyze the data. The results shows that:

[math] \sigma_x^2= (3.678 \pm 0.022) + (-4.17 \pm 0.22)k_1L + (5.55 \pm 0.42)(k_1L)^2 [/math]

[math] \epsilon_x = 0.417 \pm 0.023~mm*mrad ~\Rightarrow~ \epsilon_{n,x} = 11.43 \pm 0.64~mm*mrad[/math]

[math] \beta_x=1.385 \pm 0.065, \alpha_x=0.97 \pm 0.07 [/math]

[math]\sigma_y^2 = (2.843 \pm 0.044) + (1.02 \pm 0.52)k_1L + (3.8 \pm 1.2)(k_1L)^2 [/math]

[math] \epsilon_y = 0.338 \pm 0.065~mm*mrad ~\Rightarrow~ \epsilon_{n,y} = 9.3 \pm 1.8~mm*mrad[/math]

[math] \beta_y=1.17 \pm 0.19, \alpha_y=0.22 \pm 0.10 [/math]

Energy Spread Measurement

Current, rep-rate

Radiation Footprint

Positron detection

DAQ setup

Data Analysis

Signal extraction

For 3 MeV and on detector show all the steps

  1. Raw counts target in and out (calibrated energy)
  2. Normalized counts
  3. background subtracted
  4. Integral (zoomed in and with error)

Example of error propagation for the above

Raw counts target in and out

Lets take example of run#3735 for the data analysis.

The ingeral shown in read is from the background is subtracted spectrum.

run in: 3735 run out: 3737 Hrrl pos 27jul2012 data ana with Cuts r3735 ove r3736 No Norm DL.png Hrrl pos 27jul2012 data ana with Cuts r3735 ove r3736 No Norm DR.png

Some run parameters in 3735:

run number Reprate Run time Pulses Events e+ Counts NaI Detectors
3735 300 Hz 1002 s 301462 9045 256 +- 16

Electron Rate Calculation

A scintillator placed between quadrupole 9 and quarupole 10 (shown as in the following figures) was used to estimate electron current:

Hrrl pos jul2012 setup Scint RL 2.jpg Hrrl pos jul2012 setup Scint RL 3.jpg Hrrl pos jul2012 setup Scint RL 4.jpg


= Scintillator Charge Calbiration

The electron beam current was changed to calibrate of the scintillator. The mean of the counts in scintillator decreased in the experiment as the current decreased, the change is linear.


run# Scope Pics FC1 area nVs Scint L area nVs Scint Left (Ch9) ADC9 mean events in scaler
3703 R3703 SCNT L.png [math]1201.1 \pm 10.1[/math] [math]4.4 \pm .3[/math] 1127.75 [math] \pm[/math] .7 [math]1126 \pm 0.8 [/math] first measurement at full current 7853 7855
3705 R3704 SCNT L.png [math]776.8 \pm 112[/math] [math]7.26 \pm 4.5[/math] 782.5 [math] \pm[/math] 1 [math]791.8 \pm 0.6[/math] cut the current in half 7591
3706 R3706 SCNT L.png [math]367.7 \pm 2.32[/math] [math]6.5 \pm .34[/math] 239.1 [math] \pm[/math] 0.6 [math] 242.1 \pm 0.3 [/math] cut the current to its 1/4 th 8154


The data was fitted with three methods to find calbiration, and the average and variance them are used to find the calibration.

The first method is fit the three data points with root.

The second method, the point (0,0) introduced, and the line was forced to pass through this point. The point is introduced based on physics that when there is no electron beam, scintillator should have no counts. The slope was fitted by root. The fit is done in root.

In the second method, the curved is far off from the two data points when ADC channel number is large. The third fitting method is introduced to compensate it, in which fits are done manually. Two fits were done by this method, and average and variance of two fits were obtained.

The average and variance of these three methods were used for the calibration of the scintillator.

Fit Methods Fit Method 1 Fit Method 2 Fit Method 3 Average of Three Methods
Fit Curve Hrrl pos 27Jul2012 Charge Calb fit curve.png Hrrl pos 27Jul2012 Charge Calb fit curve fix point 1.png Hrrl pos 27Jul2012 Charge Calb fit curve my fix point 1.pngHrrl pos 27Jul2012 Charge Calb fit curve my fix point 2.png
Calibration [math] 1.063 \pm 0.013 [/math] nV s /ADC channel [math]0.789 \pm 0.004[/math] nV s /ADC channel [math] 0.94 \pm 0.02 [/math] nV s /ADC channel [math] 0.93 \pm 0.14 [/math] nV s /ADC channel
Electron Current Calculation for Run 3735

Total number of electrons in this run [math]N_{e^-}= (2.99 \pm 0.45 ) \times 10^{16}.[/math]

Total charge of electrons in this run: [math]Q_{e^-} = (4.78 \pm 0.72 ) \times 10^{-3}~C.[/math]

Electron rate: [math] e^-_{rate} = (2.97 \pm 0.45) \times 10^{13}~Hz. [/math]

Average electron current: [math]I_{e^-} = (4.8 \pm 0.8 ) \times 10^{-6}~(A).[/math]

Positron Rate Calculation

This a normalized spectrum (no background subtraction).

run in: 3735 Hrrl pos 27jul2012 data ana with Cuts r3735 Norm DL.png Hrrl pos 27jul2012 data ana with Cuts r3735 Norm DR.png

positron rate: [math] e^+_{rate} = 0.259 +- 0.016 ~ Hz.[/math]

Positron to Electron Ratio

positron to electron ratio: [math]R = \frac{N_{e^+}}{N_{e^-}} = (8.7 \pm 1.4)\times10^{-15}.[/math]

positron to electron current ratio: [math]R = \frac{N_{e^+}}{I_{e^-}} = \frac{0.26 ~ Hz ~ e^+}{4.8 ~ \mu ~ A ~ e^-}[/math]


Hand Calculation of Errors

[math]R = \frac{N_{e^+}}{N_{e^-}} = \frac{ 0.259 \pm 0.016 Hz}{ (2.98 \pm 0.45) \times 10^{13} Hz} = 0.087 \times 10^{-13} = 8.7 \times 10^{-15}[/math]


[math]\Delta R = \sqrt{\frac { \Delta N_{e^+}^2 }{ N_{e^-}^{2} } + (- \frac{ N_{e^+} }{ N_{e^-}^{2} })^2 \Delta N_{e^-}^{2} } = \frac{\sqrt{ \Delta N_{e^+}^{2} + \frac{ N_{e^+}^{2} }{ N_{e^-}^{2} } \Delta N_{e^-}^{2} }}{ N_{e^-}} = \frac{\sqrt{ \Delta N_{e^+}^{2} + R^2 \Delta N_{e^-}^{2} }}{ N_{e^-}}[/math]



[math]\Delta R = \frac{\sqrt{ 0.016^{2} + ( 8.7 \times 10^{-15} \times 4.49 \times 10^{12})^{2} }}{ 2.98\times 10^{13}} [/math]

[math] = \frac{\sqrt{ 0.016^{2} + ( 8.7 \times 4.49 \times 10^{-3})^{2} }}{ 2.98\times 10^{13}} [/math]
[math] = \frac{\sqrt{ 0.000256 + 0.001526}}{ 2.98\times 10^{13}} [/math]
[math] = \frac{\sqrt{ 0.001782}}{ 2.98\times 10^{13}} [/math]
[math] = 0.014 \times 10^{-13} [/math]
[math] = 1.4 \times 10^{-15} [/math]

Background subraction

run# [math]R = \frac{N_{e^+}}{N_{e^-}} [/math]
3735 [math](8.7 \pm 1.4)\times 10^{-15}[/math]
3736 [math](1.46 \pm 0.76)\times 10^{-16}[/math]
3737 [math](8.1 \pm 1.3)\times 10^{-15}[/math]

Sources of Systematic Errors

Efficiency measurement

acceptance, quad collection efficiency,

Conclusion

References

<references/>