Difference between revisions of "Beam Test Jul 19 2012"
Jump to navigation
Jump to search
| Line 91: | Line 91: | ||
|- | |- | ||
| − | | in || out || 4.2 || 4.2 || 2 MeV e- || 1 || V ||+1 || 0 || 0.1|| 0 || +1.3 || 0.5 || D1 & D2 set to 2 MeV e- | + | | in || out || 4.2 || 4.2 || 2 MeV e- || 1 || V ||+1 || 0 || 0.1|| 0 || +1.3 || 0.5 || 0 || D1 & D2 set to 2 MeV e- |
|} | |} | ||
Revision as of 15:35, 19 July 2012
Tune up 10 MeV on the zero line.
Insert Tungsten target and do a dipole scan to determine relative yield as a function of energy. Attempt to measure relative yield using integral of thick scintillator output for constant current and energy slit setting.
10 MeV Tune
| Energy Switch | Out (High En) |
| Solenoid 1 | 6.2 A |
| Solenoid 2 | 3.3 A |
| Gun Hor | -0.2 A |
| Gun Ver | 0 A |
| Output Hor | -0.3 A |
| Output Ver | 0 A |
| Rep Rate | 8 |
| Gun HV | 10 (Knob Setting) |
| Gun Grid Voltage | 10 (Knob Setting) |
| RF frequency | 2856.320 MHz |
| Modulator HV Power Supply | 4.28 (Knob Setting) |
| RF macro Pulse Length (FWHM) | 300 ns |
| Q1 (A) | -3.7 |
| Q2 (A) | -5.5 |
| Q3 (A) | +0.6 |
Counting single pulse
Settings
Gun Grid Voltage knob setting: 2.85
| Energy Switch | Out (High En) |
| Solenoid 1 | 6.2 A |
| Solenoid 2 | 3.3 A |
| Gun Hor | -0.2 A |
| Gun Ver | 0 A |
| Output Hor | -0.3 A |
| Output Ver | 0 A |
| Rep Rate | 8 |
| Gun HV | 10 (Knob Setting) |
| Gun Grid Voltage | 2.85 (Knob Setting) |
| RF frequency | 2856.320 MHz |
| Modulator HV Power Supply | 4.28 (Knob Setting) |
| RF macro Pulse Length (FWHM) | 300 ns |
| Q1 (A) | -3.7 |
| Q2 (A) | -5.5 |
| Q3 (A) | +0.6 |
| W1 | Sweeping magnet | D1 (A) | D2 (A) | Mode | Jaw width (cm) | Sint HV | q4 (A) | q5 (A) | q6 (A) | q7 (A) | q8 (A) | q9 (A) | q10 (A) | conditions |
| in | out | 4.2 | 4.2 | 2 MeV e- | 1 | V | +1 | 0 | 0.1 | 0 | +1.3 | 0.5 | 0 | D1 & D2 set to 2 MeV e-
|