Difference between revisions of "Beam Test Jul 19 2012"

From New IAC Wiki
Jump to navigation Jump to search
(Created page with ' Tune up 10 MeV on the zero line. Insert Tungsten target and do a dipole scan to determine relative yield as a function of energy. Attempt to measure relative yield using inte…')
 
Line 1: Line 1:
 
 
Tune up 10 MeV on the zero line.
 
Tune up 10 MeV on the zero line.
  
Line 5: Line 4:
  
 
[[File:HRRL_10MeVePdist_71812.png || 200 px]]
 
[[File:HRRL_10MeVePdist_71812.png || 200 px]]
 +
 +
= 10 MeV Tune  =
 +
 +
{| border="1"
 +
| Energy Switch || Out (High En)
 +
|-
 +
| Solenoid 1    || 6.2  A 
 +
|-
 +
| Solenoid 2      || 3.3    A
 +
|-
 +
| Gun Hor        ||  -0.2  A
 +
|-
 +
| Gun Ver        || 0 A
 +
|-
 +
|Output Hor      ||  -0.3 A
 +
|-
 +
| Output Ver    || 0  A
 +
|-
 +
| Rep Rate    || 8
 +
|-
 +
|  Gun HV  ||  10 (Knob Setting)
 +
|-
 +
|  Gun Grid Voltage  ||  10 (Knob Setting)
 +
|-
 +
|  RF frequency  ||2856.320 MHz
 +
|-
 +
|  Modulator HV Power Supply  ||  4.28 (Knob Setting)
 +
|-
 +
|  RF macro Pulse Length (FWHM)  || 300 ns
 +
|- 
 +
|Q1  (A)|| -3.7
 +
|- 
 +
|Q2  (A)|| -5.5
 +
|- 
 +
|Q3  (A)|| +0.6
 +
|- 
 +
|}

Revision as of 14:24, 19 July 2012

Tune up 10 MeV on the zero line.

Insert Tungsten target and do a dipole scan to determine relative yield as a function of energy. Attempt to measure relative yield using integral of thick scintillator output for constant current and energy slit setting.

HRRL 10MeVePdist 71812.png

10 MeV Tune

Energy Switch Out (High En)
Solenoid 1 6.2 A
Solenoid 2 3.3 A
Gun Hor -0.2 A
Gun Ver 0 A
Output Hor -0.3 A
Output Ver 0 A
Rep Rate 8
Gun HV 10 (Knob Setting)
Gun Grid Voltage 10 (Knob Setting)
RF frequency 2856.320 MHz
Modulator HV Power Supply 4.28 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) -3.7
Q2 (A) -5.5
Q3 (A) +0.6