Line 4: Line 4:
 
Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering.
 
Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering.
  
= Tune Beam =
+
= Tune The Beam for 10 MeV =
 +
 
 +
=== 2nd Tuning (10 MeV)===
 +
 
 +
{| border="1"
 +
| Energy Switch || In (Low En Range)
 +
|-
 +
| Solenoid 1    || 3.0  A 
 +
|-
 +
| Solenoid 2      || 5.2    A
 +
|-
 +
| Gun Hor        ||  0.1  A
 +
|-
 +
| Gun Ver        || 0.1 A
 +
|-
 +
|Output Hor      ||  -0.1 A
 +
|-
 +
| Output Ver    || -0.3  A
 +
|-
 +
| Rep Rate    || 10
 +
|-
 +
|  Gun HV  ||  10 (Knob Setting)
 +
|-
 +
|  Gun Grid Voltage  ||  10(Knob Setting)
 +
|-
 +
|  RF frequency  ||2856.269 MHz
 +
|-
 +
|  Modulator HV Power Supply  || 4.13 (Knob Setting)
 +
|-
 +
|  RF macro Pulse Length (FWHM)  || 300 ns
 +
|- 
 +
|Q1  (A)||0
 +
|- 
 +
|Q2  (A)|| 0
 +
|- 
 +
|Q3  (A)|| 0
 +
|- 
 +
|Q4  (A)|| 0
 +
|- 
 +
|Q5  (A)|| 0
 +
|- 
 +
|Q6  (A)|| 0
 +
|-
 +
|}

Revision as of 14:19, 16 July 2012

Camera Trig

Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering.

Tune The Beam for 10 MeV

2nd Tuning (10 MeV)

Energy Switch In (Low En Range)
Solenoid 1 3.0 A
Solenoid 2 5.2 A
Gun Hor 0.1 A
Gun Ver 0.1 A
Output Hor -0.1 A
Output Ver -0.3 A
Rep Rate 10
Gun HV 10 (Knob Setting)
Gun Grid Voltage 10(Knob Setting)
RF frequency 2856.269 MHz
Modulator HV Power Supply 4.13 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) 0
Q2 (A) 0
Q3 (A) 0
Q4 (A) 0
Q5 (A) 0
Q6 (A) 0