** @ 70 cm => 0.379 neutrons hitting the detector per pulse | ** @ 70 cm => 0.379 neutrons hitting the detector per pulse | ||
* Taking into account the efficiency of the detector <math>\epsilon_0</math>, the number detected per pulse can be found as <math>2.3*\frac{\Delta \Omega}{4\pi}*\epsilon_0</math> | * Taking into account the efficiency of the detector <math>\epsilon_0</math>, the number detected per pulse can be found as <math>2.3*\frac{\Delta \Omega}{4\pi}*\epsilon_0</math> | ||
− | ** @ 1 meter from source => 0.0198*\epsilon_0 neutrons hitting the detector per pulse | + | ** @ 1 meter from source => 0.0198* \epsilon_0 neutrons hitting the detector per pulse |
− | ** @ 70 cm from source => 0.379*\epsilon_0 neutrons hitting the detector per pulse | + | ** @ 70 cm from source => <math>0.379*\epsilon_0</math> neutrons hitting the detector per pulse |
[https://wiki.iac.isu.edu/index.php/User:Jasenswanson Go Back] | [https://wiki.iac.isu.edu/index.php/User:Jasenswanson Go Back] |
Revision as of 21:24, 29 May 2012
Big Detector Solid Angle Calculations
- MCNPX Simulation
- 14 MeV neutron source, emitted isotropically (
- Detector placed 1m away from source
- face of the detector is 15.24cm x 76.2cm, and 3.6cm deep
The solid angle can be found from the number of particles hitting the detector as:
- Results
- Out of 1E9 neutrons generated, 8618287 neutrons hit the detector
- if the detector is placed 70cm away from the source,
- As a test to verify our results
- We change the detector size to 2cm by 2cm and used 1E9 neutrons again
- 32061 neutrons struck the detector
- And, as a second test to verify our results
- We change the detector size to 1cm by 1cm and used 1E9 neutrons again
- 7965 neutrons struck the detector
- Now, what neutron singles rate into the detector should correspond to 1 fission per pulse?
- If we have 1 fission per pulse and each fission emits on average 2.3 neutrons, we should expect 2.3 neutrons/pulse
- The number of neutrons hitting the detector per pulse is found as
- @ 1 meter => 0.0198 neutrons hitting the detector per pulse
- @ 70 cm => 0.379 neutrons hitting the detector per pulse
- Taking into account the efficiency of the detector
- @ 1 meter from source => 0.0198* \epsilon_0 neutrons hitting the detector per pulse
- @ 70 cm from source => neutrons hitting the detector per pulse
, the number detected per pulse can be found as