Difference between revisions of "05/12/2011 2n correlation test"
Jump to navigation
Jump to search
(Created page with '[https://wiki.iac.isu.edu/index.php/N%27s_detector_calibration Go Back] The powers are: PS1 and PS2: -1000 V (the old 2-channel TENNELEC TC952) n's: -1100 V (the new 2-chan…') |
|||
(9 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | [https://wiki.iac.isu.edu/index.php/ | + | [https://wiki.iac.isu.edu/index.php/Roman_measurements go back] |
− | The | + | The voltages, thresholds and widths are: |
− | + | {| border="1" cellspacing="0" style="text-align: center; width: 800px; height: 100px;" | |
− | + | ! scope="col" width="50" | | |
− | + | ! scope="col" width="50" | PMT voltage, V | |
− | + | ! scope="col" width="50" | threshold, mV | |
− | + | ! scope="col" width="50" | discr. width, ns | |
− | + | |- | |
− | + | !PS1 | |
− | + | | -1000|| -80|| 20 | |
− | + | |- | |
− | + | !PS1 | |
+ | | -1000|| -80|| 10 | ||
+ | |} | ||
− | |||
− | |||
− | |||
Let's do the '''2n correlation test''' with CF252 source. The voltages and thresholds are the same. | Let's do the '''2n correlation test''' with CF252 source. The voltages and thresholds are the same. | ||
First the set up is like: | First the set up is like: | ||
− | :PS1 and PS2 are parallel to each other and are faced to the source. | + | :○ PS1 and PS2 are parallel to each other and are faced to the source. |
− | :the CF252 source in the middle | + | :○ the CF252 source in the middle |
− | :the distance between PS1(PS2) and source is 6 cm | + | :○ the distance between PS1(PS2) and source is 6 cm |
The total number of events (2n fission events + random coincident) are: | The total number of events (2n fission events + random coincident) are: | ||
Line 45: | Line 44: | ||
Second the set up is like: | Second the set up is like: | ||
− | :PS1 and PS2 are perpendicular to each other and are faced to the source. | + | :○ PS1 and PS2 are perpendicular to each other and are faced to the source. |
− | :the CF252 source in the middle | + | :○ the CF252 source in the middle |
− | :the distance between PS1(PS2) and source is 6 cm | + | :○ the distance between PS1(PS2) and source is 6 cm |
The total number of events (2n fission events + random coincident) are: | The total number of events (2n fission events + random coincident) are: |
Latest revision as of 19:01, 24 May 2012
The voltages, thresholds and widths are:
PMT voltage, V | threshold, mV | discr. width, ns | |
---|---|---|---|
PS1 | -1000 | -80 | 20 |
PS1 | -1000 | -80 | 10 |
Let's do the 2n correlation test with CF252 source. The voltages and thresholds are the same. First the set up is like:
- ○ PS1 and PS2 are parallel to each other and are faced to the source.
- ○ the CF252 source in the middle
- ○ the distance between PS1(PS2) and source is 6 cm
The total number of events (2n fission events + random coincident) are:
total counts | time | counts/min | counts/sec | |
---|---|---|---|---|
PS1 | 10 min | |||
PS1 | 10 min | |||
PS1+PS2 | 10 min |
Second the set up is like:
- ○ PS1 and PS2 are perpendicular to each other and are faced to the source.
- ○ the CF252 source in the middle
- ○ the distance between PS1(PS2) and source is 6 cm
The total number of events (2n fission events + random coincident) are:
total counts | time | counts/min | counts/sec | |
---|---|---|---|---|
PS1 | 10 min | |||
PS1 | 10 min | |||
PS1+PS2 | 10 min |