Difference between revisions of "Beam Test Apr 24 2012"
Line 16: | Line 16: | ||
=== Test beam stability at different energies === | === Test beam stability at different energies === | ||
+ | Start from 2 MeV go up energy. | ||
− | {| border=" | + | {| border="1" |
− | | | + | | Estimated Energy || Faraday Cup 1 (FC1) reading (mA) || Is FC 1 reading stable? || Beam Image |
+ | |- | ||
+ | | 2 MeV || || || [[File:hrrl_24Apr2012_EnTest_2MeV.png]] | ||
+ | |- | ||
+ | | 6 MeV || || || [[File:hrrl_24Apr2012_EnTest_6MeV.png]] | ||
+ | |- | ||
+ | | 10 MeV || || || [[File:hrrl_24Apr2012_EnTest_10MeV.png]] | ||
+ | |- | ||
+ | | 12 MeV || || || [[File:hrrl_24Apr2012_EnTest_12MeV.png]] | ||
+ | |- | ||
+ | | 14 MeV || || || [[File:hrrl_24Apr2012_EnTest_14MeV.png]] | ||
+ | |- | ||
+ | | 16 MeV || || || [[File:hrrl_24Apr2012_EnTest_16MeV.png]] | ||
|- | |- | ||
− | |||
|} | |} | ||
===2. Sadiq's tunes beam tube previous setting === | ===2. Sadiq's tunes beam tube previous setting === | ||
− | This tune used for quad scan at Mar 17 2011, tuned by Dr. Kim. | + | Tune to following settings, observe beam. Check if there is mis-steering by quadrupole magnet. |
+ | |||
+ | This tune used for quad scan at Mar 17 2011, tuned by Dr. Kim. | ||
{| border="1" | {| border="1" |
Revision as of 21:34, 23 April 2012
Getting Ready Punchlist
1) Get matlab ready for emittance measurement. (Not done due to Matlab licence issue)
(Done) 2) Install control box. (Done) 3) Clean up imaging system. (Done) 4) Determine dipole current setting.
Test List
Energy Test
1. Chad tunes HRRL
Test beam stability at different energies
Start from 2 MeV go up energy.
Estimated Energy | Faraday Cup 1 (FC1) reading (mA) | Is FC 1 reading stable? | Beam Image |
2 MeV | File:Hrrl 24Apr2012 EnTest 2MeV.png | ||
6 MeV | File:Hrrl 24Apr2012 EnTest 6MeV.png | ||
10 MeV | File:Hrrl 24Apr2012 EnTest 10MeV.png | ||
12 MeV | File:Hrrl 24Apr2012 EnTest 12MeV.png | ||
14 MeV | File:Hrrl 24Apr2012 EnTest 14MeV.png | ||
16 MeV | File:Hrrl 24Apr2012 EnTest 16MeV.png |
2. Sadiq's tunes beam tube previous setting
Tune to following settings, observe beam. Check if there is mis-steering by quadrupole magnet.
This tune used for quad scan at Mar 17 2011, tuned by Dr. Kim.
Test Mis-steering of the quad
Use OTR screen observe the beam. Turn all the quads off, except one at time. Change quad currents, see if mis-steering happens.
Emittence Test (If time allows?)
Tune HRRL establish stable beam
1. Looking at the beam position on the screen and by the beam current on FC, try to align beam line. The goal is to center the beam on the screen, and maximize the FC charge as high as possible.
2. Reduced the mis-steering at the quadrupole by tuning steerers in the linac.
3. Optimize steerers, solenoids in linac to get a round electron beam shape and no steering at the quadrupole.
4. One good tune earlier for reference: [Tune HRRL]
10 MeV
Energy is set by bending the beam to dipole at specific current.
Set dipole current for 10 MeV, and bend the beam. Tune the beam energy, until we see peak current at the 45 degree Faraday cup.
Emittance measurement at 10 MeV
This is scan for 10 MeV beam. 40 mAmps peak current. Q1 is on, All other quads are off.
1) Scan from -5 Amps to 5 Amps. Increment at 0.2 Amps.
3) Name images by numbers start from 1. Then go on. Like: -5 Amp is 1, -4.8 Amp is 2, and so on til 5 Amp is named 51.
4) Scan multiple times from -5 to 5 Amps, and put them in different folders. Name folder by number, like 1, 2, 3 etc. After finishing one scan go back to -5 Amps. When going back take small steps (like 1 Amp), do not jump from 5 Amps to -5 Amps directly. After reaching back to -5, wait for few moment (like 10 s).
5) For each time, take back ground images. It should be done when RF is on and gun is off.
6) After the scan take a scope image for the current of the FC after the OTR screen. Lower the current, so the vacuum window do not heat up. This step is to check energy.
15 MeV
Energy is set by bending the beam to dipole at specific current.
Set dipole current for 15 MeV, and bend the beam. Tune the beam energy, until we see peak current at the 45 degree Faraday cup.
Emittance measurement at 15 MeV
3 MeV
Energy is set by bending the beam to dipole at specific current.
Set dipole current for 15 MeV, and bend the beam. Tune the beam energy, until we see peak current at the 45 degree Faraday cup.
Emittance measurement at 3 MeV
7 MeV
Energy is set by bending the beam to dipole at specific current.
Set dipole current for 7 MeV, and bend the beam. Tune the beam energy, until we see peak current at the 45 degree Faraday cup.