Oportunistic Beam studies
Trigger Setup
1.) The V895 was double pulsing and its output pulse maxed out at 40 ns
The V895 "Maj" output is shown on Ch1 along with the NaI signal which was discriminated by it |
2.) inserted a gate delay generator to change the V895 output pulse to a microsecond
I took the "MAJ" output and used a Phillips Gate Generator to extend the pulse length in order to stop multiple triggers |
Run list
Run# | run mode | Run length (sec) | Beam | Target | Trig Logic | VME discriminator Threshold (mV) | HV1 (setting/V) A1 | HV2 (setting/V) A3 | PL (setting/ns) | PTW (setting/ns) |
4073 | sample | 240 | off | empty | (Det1 OR Det2) | 200 | 2.0/0.888 | 2.7/1.2 | ||
4074 | sample | off/tuning | empty | (Det1 AND Det2) | 50 | 2.2/0.888 | 3.0/1.2 | |||
4075 | sample | off/tuning | Chromox | (Det1 AND Det2 AND SYNC) | 50 | 2.2/0.888 | 3.0/1.2 | |||
4078 | sample | e+ (0.3 nA) | Chromox | (Det1 AND Det2 AND SYNC)** | 50 | 2.2/0.888 | 3.0/1.2 | |||
4079 | sample | e+ (0.3nA) | Chromox | (Det1 AND Det2)** | 50 | 2.2/0.888 | 3.0/1.2 | |||
4080 | sample | e+(1 na) | Chromox | (Det1 AND Det2 AND SYNC)** | 50 | 2.2/0.888 | 3.0/1.2 | |||
4081 | sample | 540 sec | e+(3 na) | Chromox | (Det1 AND Det2 AND SYNC)** | 50 | 2.2/0.888 | 3.0/1.2 | ||
4082 | sample | 23 min | e+(0.3 na) | Chromox | (Det1 AND Det2 AND SYNC)** | 50 | 2.2/0.888 | 3.0/1.2 | ||
4083 | sample | sec | e+(0.3 na) | Chromox | (Det1 AND Det2) | 50 | 2.2/0.888 | 3.0/1.2 | ||
4084 | sample | sec | e+(0.150 na) | Chromox | (Det1 AND Det2) | 50 | 2.2/0.888 | 3.0/1.2 | Changed discriminator to 50 mv for both channels it was at 20 the scalers will count differently now but the trigger theshold is still the same 100 mV | |
4085 | sample | sec | e+(0.15 na) | Chromox | (Det1 AND Det2 AND SYNC) | 50 | 2.2/0.888 | 3.0/1.2 | ||
4086 | sample | sec | e+(0.05 na) | Chromox | (Det1 AND Det2) | 50 | 2.2/0.888 | 3.0/1.2 |
- stop using V895 and used a discriminator (Phillips 708 set to ~100 mV) and logic unit (phillips 758)
Scope pict traces for TEK0020 -> TEK00
Ch1(Yellow)=Majority
Ch2(Blue)=Beam SYNC
Ch3(Pink)=Annih. Det. #1
Ch4(Green)=Annih. Det. #2
Data Analysis
Replay
running the decoder using the personal account on the opsmdaq0 failed; perhaps due to problems writing its output to the /data disk
to convert a data file into a rood file I needed to login to opsdaq0 under the username "idaq"
then execute the following command
/work1/fanchini/decoder/fadc_decode_Source /data/annihilation/Annihilation_Sample_4086.dat
This created the summary text file and root file for run 4086
MakeClass
Load up the ntuple and click over to the "T" tree
Then onthe command line type
T->MakeClass();
RUn analysis
Run# | Current | Run length (sec) | Trig Logic | |
4073 | 0 | 240 | (Det1 OR Det2) | |
4074 | tuning | (Det1 AND Det2) | ||
4075 | tuning | (Det1 AND Det2 AND SYNC) | ||
4078 | 0.3 | (Det1 AND Det2 AND SYNC)** | ||
4079 | 0.3 | (Det1 AND Det2)** | ||
4080 | 1 | (Det1 AND Det2 AND SYNC)** | ||
4081 | 3 | (Det1 AND Det2 AND SYNC)** | ||
4082 | 0.3 | (Det1 AND Det2 AND SYNC)** | ||
4083 | 0.3 | (Det1 AND Det2) | ||
4084 | 0.15 | (Det1 AND Det2) | ||
4085 | 0.15 | (Det1 AND Det2 AND SYNC) | ||
4086 | 0.05 | (Det1 AND Det2) |