| 2904|| sample  ||    ||e<math>^-</math>    ||  Empty  ||  Det1 AND Det2 ||        50            ||  2.4/960      ||    3/1200      ||      ||     
 
| 2904|| sample  ||    ||e<math>^-</math>    ||  Empty  ||  Det1 AND Det2 ||        50            ||  2.4/960      ||    3/1200      ||      ||     
 
|-
 
|-
| 2905|| sample  ||     || e<math>^-</math> || Chromox  ||  Det1 AND Det2 ||        50          ||  2.4/960      ||    3/1200      ||        ||     
+
| 2905|| sample  || analyzer not working  || e<math>^-</math> || Chromox  ||  Det1 AND Det2 ||        50          ||  2.4/960      ||    3/1200      ||        ||     
 
|-
 
|-
 
| 2908|| sample  || 150 ||        off      ||    out    ||  (Det1 or Det2) ||      50          ||  2.4/960      ||    3/1200      ||  74.0667% <math>\pm</math>  0.157206%  ||     
 
| 2908|| sample  || 150 ||        off      ||    out    ||  (Det1 or Det2) ||      50          ||  2.4/960      ||    3/1200      ||  74.0667% <math>\pm</math>  0.157206%  ||     
 
|-
 
|-
| 2909|| sample  || || off  ||  out  ||    (Det1 AND Det2) ||                      50          ||  2.4/960      ||    3/1200      ||        ||     
+
| 2909|| sample  || analyzer not working || off  ||  out  ||    (Det1 AND Det2) ||                      50          ||  2.4/960      ||    3/1200      ||        ||     
 
|-
 
|-
  
 
|}
 
|}

Revision as of 02:15, 15 March 2012

Accelerator Configuration

Accelerator Settings
beam energy 6.8 MeV
Beam type: Electron
I_average: 0.3 nA
I_peak: 0.05[math] \mu[/math] A 0.006 duty factor
pulse width: 10 [math]\mu[/math]s (it seems on 200 [math] \mu[/math]s is possible?)
Rate: 60 Hz
PEPPO Spectrometer: 151.3 A

Set HV to Detectors

Signal channel HV dac HV (V)
Detectors #1 A1 2.4 960
Detectors #2 A2 3.0 1200

How to turn HV On


Scope Pictures

CH1: Beam Sync CH2: A1 CH3: A2

Target Pictures
No Target 1 03132012 AnnhCountScopePic.png 2 03132012 AnnhCountScopePic.png
Chromox Target 3 03132012 AnnhCountScopePic.png 4 03132012 AnnhCountScopePic.png

Annihilation Counter Runs

Signal Definitions for Trigger logic
SYNC:=60 Hz sync pulse 200 micro seconds long
Det1:= Annihilation Counter #1 (HV1)
Det2:=Annihilation Counter #2 (HV2)



Run# run mode Run length (sec) Beam Target Trig Logic VME discriminator Threshold (mV) HV1 (setting/V) HV2 (setting/V) Deadtime
2902 sample e[math]^-[/math] Chromox (Det1 OR Det2) 50 2.4/960 3/1200
2903 sample 203 e[math]^-[/math] Empty (Det1 OR Det2) 50 2.4/960 3/1200 84.9788% [math]\pm[/math]0.106622%
2904 sample e[math]^-[/math] Empty Det1 AND Det2 50 2.4/960 3/1200
2905 sample analyzer not working e[math]^-[/math] Chromox Det1 AND Det2 50 2.4/960 3/1200
2908 sample 150 off out (Det1 or Det2) 50 2.4/960 3/1200 74.0667% [math]\pm[/math] 0.157206%
2909 sample analyzer not working off out (Det1 AND Det2) 50 2.4/960 3/1200