Difference between revisions of "September 9, 2011"

From New IAC Wiki
Jump to navigation Jump to search
 
(24 intermediate revisions by 2 users not shown)
Line 12: Line 12:
 
! scope="col" width="60%" | Comments
 
! scope="col" width="60%" | Comments
 
|-
 
|-
|2339||Up 2 mm||In ||Open ||Up 2 mm||No ||align="left"|'''R(upstr) = 2648/35092 = 0.075 e+/pulse''',\newline '''R(downstr) = 3191/35092 = 0.091 e+/pulse'''
+
|2339||Up 2 mm||In ||Open ||Up 2 mm||No  
 +
|align="left"|R(upstream) = 2648/35092 = 0.075 e+/pulse,<br>R(downstream) = 3191/35092 = 0.091 e+/pulse
 
|-
 
|-
|2341||Up 2 mm||In ||Open ||Out||No ||align="left"|<span style="color:blue">R(upstream) = 1088/35494 = 0.031 e+/pulse, R(downstream) = 1328/35494 = 0.037 e+/pulse.</span> <span style="color:red">About 59% of photons are coming from the radiator. Bad</span>
+
|2341||Up 2 mm||In ||Open ||Out||No  
 +
|align="left"|R(upstream) = 1088/35494 = 0.031 e+/pulse,<br> R(downstream) = 1328/35494 = 0.037 e+/pulse.
 +
<span style="color:red">About 59% of photons are coming from the radiator. Bad</span>
 
|-
 
|-
|2342||Down 2 mm||In ||Open ||Out||No ||align="left"|<span style="color:blue">R(upstream) = 1586/36678 = 0.043 e+/pulse, R(downstream) = 1888/36678 = 0.051 e+/pulse.</span>
+
|2342||Down 2 mm||In ||Open ||Out||No  
 +
|align="left"|R(upstream) = 1586/36678 = 0.043 e+/pulse,<br>R(downstream) = 1888/36678 = 0.051 e+/pulse.
 
|-
 
|-
 
|2343||Down 2 mm||In ||Open ||Down 2 mm||No  
 
|2343||Down 2 mm||In ||Open ||Down 2 mm||No  
|align="left"|<span style="color:blue">R(upstream) = 2232/35488 = 0.063 e+/pulse. <span style="color:red">About 32% of photons are coming from the radiator. Bad</span>
+
|align="left"|R(upstream) = 2232/35488 = 0.063 e+/pulse.
 +
<span style="color:red">About 32% of photons are coming from the radiator. Bad</span>
 
|-
 
|-
|2344||Centered||In ||Open ||Centered||No ||align="left"|<span style="color:blue">R(upstream) =  2683/35095 = 0.076 e+/pulse.</span>
+
|2344||Centered||In ||Open ||Centered||No  
 +
|align="left"|R(upstream) =  2683/35095 = 0.076 e+/pulse.
 
|-
 
|-
|2345||Centered||In ||Open ||Out||No ||align="left"|<span style="color:blue">R(upstream) =  1039/35094 = 0.029 e+/pulse.</span> <span style="color:red">About 62% of photons are coming from the radiator. Bad</span>
+
|2345||Centered||In ||Open ||Out||No  
 +
|align="left"|R(upstream) =  1039/35094 = 0.029 e+/pulse.
 +
<span style="color:red">About 62% of photons are coming from the radiator. Bad</span>
 
|-
 
|-
|2346||Centered||In ||Open ||Out||No ||align="left"|<span style="color:blue">PS Rate is: R(upstream) =  1286/35885 = 0.036 e+/pulse.</span> Improved shielding around dump.  
+
|2346||Centered||In ||Open ||Out||No  
 +
|align="left"|R(upstream) =  1286/35885 = 0.036 e+/pulse.
 +
Improved shielding around dump.  
 
|-
 
|-
|colspan="6"| ||align="left"|<span style="color:green">Based on the previous results the beam is total crap, so beam turn up.</span>  
+
|colspan="6"| ||align="left"|<span style="color:green">Based on the previous results the beam is total crap, so beam tuned up.</span>  
 
|-
 
|-
|2349||Centered||In ||Open ||Out||No ||align="left"|<span style="color:blue">PS Rate is: R(upstream) =  404/35489 = 0.011 e+/pulse.</span>
+
|2349||Centered||In ||Open ||Out||No  
 +
|align="left"|R(upstream) =  404/35489 = 0.011 e+/pulse.
 
|-
 
|-
|2350||Centered||In ||Open ||Out||No ||align="left"|<span style="color:blue">PS Rate is: R(upstream) =  428/35093 = 0.012 e+/pulse.</span> Additional shielding around the vacuum window of the beam pipe.
+
|2350||Centered||In ||Open ||Out||No  
 +
|align="left"|R(upstream) =  428/35093 = 0.012 e+/pulse.
 +
Additional shielding around the vacuum window of the beam pipe.
 
|-
 
|-
|2351||Centered||In ||Open ||Centered||No ||align="left"|PS Rate is: R(upstream) =  1314/35094 = 0.037 e+/pulse. Additional shielding around the vacuum window of the beam pipe is removed. <span style="color:red">About 68% of photons are coming from the radiator. Still bad</span>
+
|2351||Centered||In ||Open ||Centered||No  
 +
|align="left"|R(upstream) =  1314/35094 = 0.037 e+/pulse.
 +
<span style="color:red">About 68% of photons are coming from the radiator. Still bad.</span>  
 +
Additional shielding around the vacuum window of the beam pipe is removed.
 
|-
 
|-
|2352||Up 2 mm||In ||Open ||Up 2 mm||D2O buttle ||align="left"|Asymmetry production run. About 40 min
+
|2352||Up 2 mm||In ||Open ||Up 2 mm||D2O bottle ||align="left"|Production run.
 
|-
 
|-
|2353||Up 2 mm||In ||Open ||Out||D2O buttle ||align="left"|plan About 30 min.
+
|2353||Up 2 mm||In ||Open ||Out||D2O bottle ||align="left"|background check<br>
 +
threshold @A22 lowered to -100 mV
 +
|-
 +
|2354||Up 2 mm||In ||Open ||Up 2 mm||DU plate
 +
|align="left"|R(upstream) = 4228/188008 = 0.022 e+/pulse,<br>R(downstream) = 5169/188008 = 0.027 e+/pulse
 +
Production run.
 +
|-
 +
|2355||Up 2 mm||In ||Open ||Out ||DU plate
 +
|align="left"|R(upstream) = 766/44747 = 0.017 e+/pulse,<br>R(downstream) = 962/44747 = 0.021 e+/pulse
 +
<span style="color:red">background check: about the same as w/ radiator in. Bad.</span><br> Threshold @A20 lowered to -100 mV
 
|-
 
|-
 
|}
 
|}
Line 57: Line 82:
  
 
[[File:12pm_downstream.jpg | 500px]]
 
[[File:12pm_downstream.jpg | 500px]]
 +
 +
 +
 +
 +
[https://wiki.iac.isu.edu/index.php/September_9,_2011 go up]

Latest revision as of 16:57, 16 September 2011

go back

summary what was been done

Run # Beam Dump magnet Collimator Radiator 10 um Al Target Comments
2339 Up 2 mm In Open Up 2 mm No R(upstream) = 2648/35092 = 0.075 e+/pulse,
R(downstream) = 3191/35092 = 0.091 e+/pulse
2341 Up 2 mm In Open Out No R(upstream) = 1088/35494 = 0.031 e+/pulse,
R(downstream) = 1328/35494 = 0.037 e+/pulse.

About 59% of photons are coming from the radiator. Bad

2342 Down 2 mm In Open Out No R(upstream) = 1586/36678 = 0.043 e+/pulse,
R(downstream) = 1888/36678 = 0.051 e+/pulse.
2343 Down 2 mm In Open Down 2 mm No R(upstream) = 2232/35488 = 0.063 e+/pulse.

About 32% of photons are coming from the radiator. Bad

2344 Centered In Open Centered No R(upstream) = 2683/35095 = 0.076 e+/pulse.
2345 Centered In Open Out No R(upstream) = 1039/35094 = 0.029 e+/pulse.

About 62% of photons are coming from the radiator. Bad

2346 Centered In Open Out No R(upstream) = 1286/35885 = 0.036 e+/pulse.

Improved shielding around dump.

Based on the previous results the beam is total crap, so beam tuned up.
2349 Centered In Open Out No R(upstream) = 404/35489 = 0.011 e+/pulse.
2350 Centered In Open Out No R(upstream) = 428/35093 = 0.012 e+/pulse.

Additional shielding around the vacuum window of the beam pipe.

2351 Centered In Open Centered No R(upstream) = 1314/35094 = 0.037 e+/pulse.

About 68% of photons are coming from the radiator. Still bad. Additional shielding around the vacuum window of the beam pipe is removed.

2352 Up 2 mm In Open Up 2 mm D2O bottle Production run.
2353 Up 2 mm In Open Out D2O bottle background check

threshold @A22 lowered to -100 mV

2354 Up 2 mm In Open Up 2 mm DU plate R(upstream) = 4228/188008 = 0.022 e+/pulse,
R(downstream) = 5169/188008 = 0.027 e+/pulse

Production run.

2355 Up 2 mm In Open Out DU plate R(upstream) = 766/44747 = 0.017 e+/pulse,
R(downstream) = 962/44747 = 0.021 e+/pulse

background check: about the same as w/ radiator in. Bad.
Threshold @A20 lowered to -100 mV

Beam Realignment

Screen shot using Phosphorous screen

9 9 11 10am.jpg

Electron beam on glass

E-glass.jpg

12pm upstream view screen

12pm upstream.jpg

12pm downstream view screen

12pm downstream.jpg



go up