Difference between revisions of "September 13, 2011"
Line 56: | Line 56: | ||
R(beam down) = 19/200289 = 0.0000949 n/pulse<br> | R(beam down) = 19/200289 = 0.0000949 n/pulse<br> | ||
R(upstream) = 1113/200289 = 0.00556 e+/pulse<br> | R(upstream) = 1113/200289 = 0.00556 e+/pulse<br> | ||
− | <span style="color:red">About | + | <span style="color:red">About 75% of photons are coming from the radiator according to PS!</span><br> |
|- | |- | ||
|2398||Down 2 mm||In ||Open ||Down 2 mm||DU plate | |2398||Down 2 mm||In ||Open ||Down 2 mm||DU plate |
Revision as of 17:29, 13 September 2011
summary what was been done
Run # | Beam | Dump magnet | Collimator | Radiator 10 um Al | Target | Comments |
---|---|---|---|---|---|---|
2385 | Up 2 mm | In | Open | Out | DU plate | Beam check-in run. Beam hardener off. DU plate 45/45 degree orientation and gammas hit the bottom right corner of plate from upstream view.
R(beam 45 left) = 6/173553 = 0.0000346 n/pulse |
2386 | Up 2 mm | In | Open | Up 2 mm | DU plate | Beam check-in run. 1" of Al hardener in front of upstream radiator.
R(beam 45 left) = n/pulse |
2387 | Up 2 mm | In | Open | Up 2 mm | DU plate | Lost beam |
2388 | Up 2 mm | In | Open | Up 2 mm | DU plate | Beam check-in run. Hardener in as before. Target realignment, now the gammas hit the center of DU plate, which is as before 45/45 degree orientation
R(beam 45 left) = n/pulse |
2389-2395 | Up 2 mm | In | Open | Up 2 mm | DU plate | Detectors set-up. Two of them are non-working. |
2396 | Up 2 mm | In | Open | Up 2 mm | DU plate | HV on A22 and A24 are -1700V. Detector check run. All setup as before. Radiator in/out test
R(beam 45 left) = 104/216929 = 0.000479 n/pulse |
2397 | Up 2 mm | In | Open | Out | DU plate | Radiator in/out test
R(beam 45 left) = 9/200289 = 0.0000449 n/pulse |
2398 | Down 2 mm | In | Open | Down 2 mm | DU plate | Radiator in/out test
R(beam 45 left) = n/pulse |
2399 | Down 2 mm | In | Open | Out | DU plate | Radiator in/out test
R(beam 45 left) = n/pulse |