Difference between revisions of "September 12, 2011"

From New IAC Wiki
Jump to navigation Jump to search
Line 41: Line 41:
 
<span style="color:red">About 86% of photons are coming from the radiator. No bad</span>
 
<span style="color:red">About 86% of photons are coming from the radiator. No bad</span>
 
|-
 
|-
 +
|2365||Up 2 mm||In ||Open ||Up 2 mm||No
 +
|align="left"|Test radiator in/out. Added 2" Al hardener against Cu bricks after vacuum window.
 +
 +
R(upstream) = 777/50837 = 0.0153 e+/pulse,<br> R(downstream) = 847/50837 = 0.0167 e+/pulse<br>
 +
<span style="color:red">About 86% of photons are coming from the radiator. No bad</span>
 +
|-
 +
  
 
|}
 
|}

Revision as of 15:48, 12 September 2011

go back

summary what was been done

Run # Beam Dump magnet Collimator Radiator 10 um Al Target Comments
2359 Centered In Open Out No Test radiator in/out.

R(upstream) = 157/40244 = 0.0039 e+/pulse,
R(downstream) = 183/40244 = 0.0045 e+/pulse

2360 Centered In Open Centered No Test radiator in/out.

R(upstream) = 898/40244 = 0.0223 e+/pulse,
R(downstream) = 1040/40244 = 0.0258 e+/pulse
About 83% of photons are coming from the radiator. No bad

2361 Up 2 mm In Open Up 2 mm No Test radiator in/out.

R(upstream) = 730/40839 = 0.0179 e+/pulse,
R(downstream) = 867/40839 = 0.0212 e+/pulse

2362 Up 2 mm In Open Out No Test radiator in/out.

R(upstream) = 172/41035 = 0.0042 e+/pulse,
R(downstream) = 258/41035 = 0.0063 e+/pulse
About 77% of photons are coming from the radiator. No bad

2363 Up 2 mm In Open Out No Test radiator in/out. Added 1" Al hardener against Cu bricks after vacuum window.

R(upstream) = 87/41037 = 0.0021 e+/pulse,
R(downstream) = 119/41037 = 0.0029 e+/pulse

2364 Up 2 mm In Open Up 2 mm No Test radiator in/out. Added 1" Al hardener against Cu bricks after vacuum window.

R(upstream) = 777/50837 = 0.0153 e+/pulse,
R(downstream) = 847/50837 = 0.0167 e+/pulse
About 86% of photons are coming from the radiator. No bad

2365 Up 2 mm In Open Up 2 mm No Test radiator in/out. Added 2" Al hardener against Cu bricks after vacuum window.

R(upstream) = 777/50837 = 0.0153 e+/pulse,
R(downstream) = 847/50837 = 0.0167 e+/pulse
About 86% of photons are coming from the radiator. No bad