A simulation was done using MCNPX to see how neutron scattering impacts asymmetry measurements.  The setup is shown below.  Neutrons were created inside a bottle of D2O and given an initial direction towards the 0 degree detector.  The size of the target and detectors are the actual size used in the experiment.  The distance between the target and each detector is 1 meter.   
A simulation was done using MCNPX to see how neutron scattering impacts asymmetry measurements.  The setup is shown below.  Neutrons were created inside a bottle of D2O and given an initial direction towards the 0 degree detector.  The size of the target and detectors are the actual size used in the experiment.  The distance between the target and each detector is 1 meter.   
----
----
[[File:MCNPX_8_3_pg1.jpg]]
[[File:MCNPX_8_3_pg1.jpg | 600px]]
----
----
A neutron energy distribution was put into MCNPX based off the actual energy distribution from the experimental data.   
A neutron energy distribution was put into MCNPX based off the actual energy distribution from the experimental data.   
----
----
[[File:MCNPX_8_3_pg2.jpg | 600px]]
[[File:MCNPX_8_3_pg2.jpg | 800px]]
----
----
The asymmetry results are shown below.
The asymmetry results are shown below.
----
----
[[File:MCNPX_8_3_pg3.jpg]]
[[File:MCNPX_8_3_pg3.jpg | 800px]]


[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL back]
[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL back]

Latest revision as of 19:06, 3 August 2011

File:Neutron asymmetry.pdf


MCNPX Results

A simulation was done using MCNPX to see how neutron scattering impacts asymmetry measurements. The setup is shown below. Neutrons were created inside a bottle of D2O and given an initial direction towards the 0 degree detector. The size of the target and detectors are the actual size used in the experiment. The distance between the target and each detector is 1 meter.



A neutron energy distribution was put into MCNPX based off the actual energy distribution from the experimental data.



The asymmetry results are shown below.